Skip to main content

Table 3 Results of two-way ANOVA for flexural strength, Vickers hardness, and fracture toughness

From: Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study

Test method

Source of variation

Sum of squares

df

Mean square

F

p

Flexural strength

Material

820,499.7

4

205,124.9

20,258.7

0.001**

 

Aging

8716.5

1

8716.5

860.9

0.001**

 

Material*Aging

12,610.5

4

3152.6

311.4

0.001**

 

Error

911.3

90

10.1

  
 

Total

4,101,565.2

100

   

Vickers hardness

Material

526.6

4

131.6

156,616.9

0.001**

 

Aging

0.4

1

0.4

491.9

0.001**

 

Material*Aging

0.8

4

0.2

246.2

0.001**

 

Error

0.1

90

0.0

  
 

Total

2344.4475

100

   

Fracture toughness

Material

15.2

4

3.8

3984.7

0.001**

 

Aging

0.8

1

0.8

851.4

0.001**

 

Material*Aging

1.2

4

0.3

311.6

0.001**

 

Error

0.1

90

0.0

  
 

Total

278.2

100

   
  1. Two-way ANOVA
  2. **p < 0.01