Skip to main content

Table 2 The configuration of parameters set for dynamic aging

From: Effects of dynamic aging on the wear and fracture strength of monolithic zirconia restorations

Parameter Data
Number of cycles 1.200.000
Force 49 N
Height 3 mm
Lateral movement 1 mm
Descendent speed 60 mm/s
Lifting speed 60 mm/s
Feed speed 40 mm/s
Return speed 40 mm/s
Frequency 1.6 Hz