Table 1 Effect of different cleaning methods in the removal of C. albicans from acrylic bars

From: Efficacy of removing Candida albicans from orthodontic acrylic bases: an in vitro study

Treatment method

CFU/bar, mean ± SD (range) n = 3

Reduction %

Statistical analysis, P values

CFU/bar with no treatment (Control)

CFU/bar after treatment

Comparison with control

Inter-treatment comparison

Brushing

9133 ± 3282 (4300–15,100)

918.7 ± 267.7 (620–1420)

89.9

< 0.01

To Tablet > 0.05 (0.092)

To CHX > 0.05 (0.323)

To US > 0.05 (0.095)

Tablets

0 ± 0 (0–0)

100

< 0.01

To CHX > 0.05 (0.479)

To US > 0.05 (0.990)

CHX

382.7 ± 131.1 (180–620)

95.8

< 0.01

To US > 0.05 (0.487)

US

6.67 ± 11.13 (0–30)

99.9

< 0.01

N/A

  1. CHX chlorhexidine, US ultrasonic cleaner