Skip to main content

Table 1 Characteristics of included studies

From: Clinical evidence of photobiomodulation therapy (PBMT) on implant stability and success: a systematic review and meta-analysis

Author(year)

Country

Sample size

Mean age (range)

Study type

The position of implant

Type of implant and surface

Bone condition

Performed analysis

Evaluation time

Abohabib(2018)

Egypt

15

20.9 ± 3.4

Split mouth

Between the maxillary second premolar and first molar buccally

AbsoAnchor orthodontic mini-implants (AbsoAnchor, Dentos, Daegu, Korea) with a diameter of 1.5 mm and a length of 8 mm

NR

RFA in Hertz

Immediately and 1, 2, 3, 4, 6, 8, 10 weeks later

Mandić(2015)

Serbia

12

61.28(55–75)

Split mouth

Premolar and/or molar maxillary regions

Self-tapping BlueSky® implants(Bredent, Germany) with a diameter of 4 mm and a length of 10 mm

Type D3 and D4

RFA in ISQ

Immediately and 1, 2, 3, 4, 5, 6 weeks later

Karaca(2018)

Turkey

25

51.2 ± 2.3(36–64)

NR

Posterior mandible

DTI Implant Systems(Istanbul, Turkey) with a diameter of 4 or 4.5 mm and a length of 10 mm

Minimum 12 mm above the mandibular canal and minimum 5.0 mm in width

RFA in ISQ

Immediately and 6 months later

García-Morales (2012)

Brazil

8

36(20–55)

Split mouth

Posterior mandible

XiVE-S implants(Dentsply Friadent, Mannheim, Germany) with a diameter of 3.8 mm and a length of 11 mm

Type 2

RFA in ISQ

Immediately,10 days and 3,6,9,12 weeks later

Memarian(2018)

Iran

12

NR

Split mouth

Mandible(one in the midline and the other two at the left and right canine teeth positions)

DIO implants (Korea) with resorbable blast media surface(invasive fungal infections-tissue level)

Type 2 or 3

PTV

Immediately and 3,4,8 weeks later

Ekizer(2016)

Turkey

20

16.77 ± 1.41 (13.1–19)

Split mouth

Between the roots of maxillary first molars and second premolars

Screw-shaped titanium orthodontic miniscrews with a diameter of 1.6 mm and a length of 8 mm

NR

RFA in ISQ

Immediately and 1,2,3 months later

Gokmenoglu (2014)

Turkey

15

LED:50.43 ± 9.25; C:45.87 ± 13.46

NR

NR

XiVE implants(Dentsply-Friadent, Mannheim, Germany) with a diameter of 3.8 (3.5–4.5)mm and a length of 11.0(11–11)mm in LED group, while with a diameter of 4.5((3.8–4.5)mm and a length of 11.0 (10.6–11.0)mm in control group

Type 2 or 3

RFA in ISQ

Immediately and 2,4,8,12 weeks later

Torkzaban(2017)

Iran

19

Female:43

Male:40.8

NR

Maxillary teeth

Dio implants (Dio UF, Busan, Korea) with a diameter of 4 or 4.5 mm a length of 10 or 11.5 mm

Type D3 and D4

RFA in ISQ

Immediately,10 days and 3,6,12 weeks later

  1. NR Not reported, RFA Resonant frequency analysis, PTV Periotest value, ISQ Implant stability quotient, C Control group