Skip to main content

Table 3 Upper surfaces; distribution of measurements according to material, heat and varnish application state

From: Microhardness of glass carbomer and high-viscous glass Ionomer cement in different thickness and thermo-light curing durations after thermocycling aging

Material

Heat

Varnish

Before Aging

 

After Aging

 

GCP

Non-exposed

Varnished

77.67±6.35

a,x

64.91±6.31

a,y

Unvarnished

72.42±10.61

a,x

58.93±10.97

b,y

60 sec

Varnished

81.94±6.49

a,x

70.94±6.55

a,y

Unvarnished

81.89±5.22

a,x

69.4±5.01

a,y

90 sec

Varnished

79.47±4.25

a,x

71.34±4.28

a,y

Unvarnished

88.1±7.59

b,x

77.33±7.91

b,y

Equia Forte

Non-exposed

Varnished

125.6±6.79

a,x

118.35±6.82

a,y

Unvarnished

120.12±9.9

a,x

111.87±9.99

b,y

60 sec

Varnished

110.28±13.26

a,x

105.95±12.01

a,y

Unvarnished

120.96±9.05

b,x

114.13±9.06

b,y

90 sec

Varnished

112.22±13.23

a,x

108.22±13.27

a,y

Unvarnished

123.83±8.12

b,x

118.99±8.19

b,y

  1. (a, b: column comparison / x, y: row comparison). (a, b and x, y): The same letters indicate an insignificant difference among the groups (p < 0.05). The a and b letters indicate the relationships between the two lines, where measurements based on varnish variations are specified. It does not specify the relationships among the groups in terms of temperature or material differences