From: Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
 | CS 3600® | CS 3700® | DWIO® | EMERALD® | EMERALD S® | ITERO ELEMENTS 5D® | MEDIT I-500® | OMNICAM® | PRIMESCAN® | RUNEYES® | TRIOS 3® | VIRTUO VIVO® |
---|---|---|---|---|---|---|---|---|---|---|---|---|
CS 3600® |  | −4.1 (8.9) | 73.5 (18.7) | 37.1 (11.6) | 38.8 (7.2) | −1.8 (4.5) | − 0.8 (5.5) | 3.6 (10.3) | −2.2 (4.2) | −19.4 (6.0) | 22.4 (8.2) | 15.0 (9.1) |
CS 3700® | 1.0 |  | 77.7 (20.5) | 41.2 (17.2) | 42.9 (11.4) | 2.3 (12.6) | 3.3 (11.3) | 7.8 (7.7) | 1.9 (7.5) | −15.2 (10.9) | 26.6 (14.2) | 19.2 (6.8) |
DWIO® | 0.005 | 0.009 |  | −36.5 (26.3) | −34.8 (24.8) | −75.4 (17.8) | −74.4 (14.4) | −69.9 (23.7) | − 75.8 (15.4) | −92.9 (15.0) | −51.1 (13.0) | −58.5 (24.3) |
EMERALD® | 0.06 | 0.4 | 1.0 |  | 1.7 (14.3) | −38.9 (11.4) | −37.9 (12.5) | − 33.5 (12.5) | −39.3 (14.2) | −56.5 (16.1) | −14.7 (13.6) | −22.1 (14.2) |
EMERALD S® | < 0.0001 | 0.010 | 1.0 | 1.0 |  | −40.6 (9.4) | −39.6 (12.6) | −35.1 (13.1) | −41.0 (10.8) | −58.1 (11.2) | −16.3 (14.9) | −23.7 (10.4) |
ITERO ELEMENTS 5D® | 1.0 | 1.0 | 0.002 | 0.03 | 0.001 |  | 1.0 (5.1) | 5.4 (12.8) | − 0.4 (6.8) | −17.6 (7.9) | 24.2 (6.1) | 16.8 (13.4) |
MEDIT I-500® | 1.0 | 1.0 | < 0.0001 | 0.1 | 0.08 | 1.0 |  | 4.4 (12.0) | −1.4 (4.2) | −18.6 (6.4) | 23.2 (3.1) | 15.8 (12.7) |
OMNICAM® | 1.0 | 1.0 | 0.1 | 0.2 | 0.2 | 1.0 | 1.0 |  | −5.8 (10.4) | −23.0 (14.7) | 18.8 (14.5) | 11.4 (8.4) |
PRIMESCAN® | 1.0 | 1.0 | < 0.0001 | 0.2 | 0.008 | 1.0 | 1.0 | 1.0 |  | −17.2 (4.8) | 24.6 (7.1) | 17.2 (9.7) |
RUNEYES® | 0.06 | 1.0 | < 0.0001 | 0.02 | < 0.0001 | 0.5 | 0.1 | 0.9 | 0.02 |  | 41.8 (8.2) | 34.4 (11.7) |
TRIOS 3® | 0.2 | 0.8 | 0.005 | 1.0 | 1.0 | 0.005 | < 0.0001 | 1.0 | 0.03 | < 0.0001 |  | −7.4 (15.7) |
VIRTUO VIVO® | 0.9 | 0.2 | 0.4 | 0.9 | 0.5 | 1.0 | 1.0 | 1.0 | 0.8 | 0.1 | 1.0 |  |