Skip to main content

Table 1 Amount of linear tooth movement measured in mm as determined by each software package

From: Digital model superimpositions: are different software algorithms equally accurate in quantifying linear tooth movements?

Type

Movements

No

DS

Mean ± S.D

Geomagic

Mean ± S.D

OrthoAnalyzer

Mean ± S.D

Compare

Mean ± S.D

Maxillary

OG

166

0.508 ± 0.8

0.470 ± 0.8

0.244 ± 0.5

0.397 ± 0.7

MD

225

− 0.203 ± 1.0

− 0.177 ± 0.9

− 0.045 ± 0.6

− 0.132 ± 0.8

BL

212

− 0.138 ± 1.4

− 0.133 ± 1.3

− 0.076 ± 1.1

− 0.115 ± 1.2

Mandibular

OG

176

0.861 ± 0.9

0.767 ± 0.8

0.641 ± 0.8

0.809 ± 0.8

MD

216

− 0.209 ± 1.1

− 0.186 ± 1.0

− 0.162 ± 0.7

− 0.196 ± 1.0

BL

190

− 0.129 ± 1.3

− 0.097 ± 1.2

− 0.058 ± 1

− 0.108 ± 1.2

Overall

OG

342

0.690 ± 0.9

0.623 ± 0.8

0.448 ± 0.7

0.609 ± 0.8

MD

441

− 0.206 ± 1.0

− 0.181 ± 0.9

− 0.102 ± 0.7

− 0.163 ± 0.9

BL

402

− 0.134 ± 1.3

− 0.116 ± 1.2

− 0.067 ± 1.1

− 0.112 ± 1.2

  1. Data was expressed using Mean ± SD
  2. DS Digital Setup, OG Occlusogingival, MD Mesiodistal, BL Buccolingual