Table 1 Criteria for implant success

From: Success and patient satisfaction of immediately loaded zirconia implants with fixed restorations one year after loading

Implant quality scale group

Clinical conditions

Success (optimum health)

No pain or tenderness upon function

0 mobility

 < 2 mm radiographic bone loss from initial surgery

No exudates history

Satisfactory survival

No pain on function

0 mobility

2–4 mm radiographic bone loss

No exudates history

Compromised survival

May have sensitivity on function

0 mobility

Radiographic bone loss > 4 mm (less than ½ of implant body)

Probing depth > 7 mm

May have exudates history

Failure (clinical or absolute failure)

Any of following:

Pain on function

Mobility

Radiographic bone loss > ½ length of implant

Uncontrolled exudate