Skip to main content

Table 2 Results of two-way ANOVA for biaxial flexural strength and Vickers hardness

From: Effect of thermocycling on the mechanical properties of permanent composite-based CAD-CAM restorative materials produced by additive and subtractive manufacturing techniques

Test method

Source of variation

Sum of squares

df

Mean square

F

p

Biaxial flexural strength

Material

198073,96

4

49518,49

46,60

0,001

Aging

687,54

1

687,54

0,64

0,466

Material x Aging

4250,27

4

1062,56

1,15

0,338

Error

83121,52

90

923,572

  

Total

4666115,39

100

   

Vickers hardness

Material

3542703,27

4

885675,81

536,77

0,000

Aging

3491,31

1

3491,31

2,11

0,219

Material x Aging

6599,95

4

1649,98

22,06

0,000

Error

6728,84

90

74,765

  

Total

3079535,95

100

   
  1. P < 0,05