Skip to main content

Table 6 Modular evaluation system, module for screening, both occlusal/incisal and non-occlusal/non-incisal [4-point ordinal scale]

From: A plea for the development of an universally accepted modular tooth wear evaluation system

Score Description
0 No (visible) wear
1 Wear within the enamel
2 Wear with dentin exposure
- horizontal less than 50 % of the area
or
- loss of clinical crown height ≤1/2
3 Wear with dentin exposure
- horizontal more than 50 % of the area
or
- loss of clinical crown height >1/2