From: Trueness of CAD/CAM digitization with a desktop scanner – an in vitro study
95%CI | p | |
---|---|---|
Inside | ||
Impression vs Mastercast | 0.109, 0.141 | < 0.001 |
Mastercast vs Sectioned cast | − 0.186, − 0.13 | < 0.001 |
Sectioned cast vs Laboratory scanner | − 0.083, − 0.038 | < 0.001 |
Impression vs Laboratory scanner | − 0.118, − 0.069 | < 0.001 |
Outside | ||
Impression vs Mastercast | 0.103, 0.159 | < 0.001 |
Mastercast vs Sectioned cast | −0.161, − 0.128 | < 0.001 |
Sectioned cast vs Laboratory scanner | −0.075, − 0.02 | < 0.001 |
Impression vs Laboratory scanner | − 0.094, − 0.027 | < 0.001 |
Left side | ||
Impression vs Mastercast | 0.162, 0.312 | < 0.001 |
Mastercast vs Sectioned cast | −0.291, − 0.195 | < 0.001 |
Sectioned cast vs Laboratory scanner | −0.173, − 0.071 | < 0.001 |
Impression vs Laboratory scanner | − 0.208, − 0.047 | 0.002 |