Skip to main content

Table 2 Data collected at the time of re-entry surgery (T1)

From: Clinical and volumetric outcomes after vertical ridge augmentation using computer-aided-design/computer-aided manufacturing (CAD/CAM) customized titanium meshes: a pilot study

Num. ID Bone density Pseudo- periosteum type Num. of implants Implant sites PBV
(mm3)
LBV
(mm3)
RBV
(mm3)
RR
%
VBG
(mm)
Surgical Complic. Healing Complic.
1 Medium 2 4 #13, #11, #21, #23 930.0 225.0 705.0 75.8 2.5 . .
2 Medium 1 3 #45, #46, #47 1430.0 51.0 1379.0 96.4 5.8   .
3 Soft 1 3 #14, #15, #16 960.0 224.0 736.0 76.7 3.9 Permanent Paresthesia .
4 Hard 2 2 #32, #42 1870.0 17.0 1853.0 99.1 . . .
5 Hard 1 2 #45, #47 450.0 33.0 417.0 92.7 3.4 . .
6 Medium 1 2 #36, #37 840.0 81.0 759.0 90.4 5.3 . .
7 Medium 1 3 #12, #14, #16 1060.0 46.0 1014.0 95.7 3.5 Temporary Paresthesia .
8 Medium 2 3 #22, #24, #26 930.0 53.0 877.0 94.3 4.2   .
9 Hard 1 3 #33, #35, #36 780.0 28.0 752.0 96.4 8.5 . .
10 Medium 3 1 #11 590.0 160.0 430.0 72.9 3.5 Hematoma Exposure
  1. Abbreviations: Num. Number; PBV Planned Bone Volume; LBV Lacking Bone Volume; RBV Regenerated Bone Volume; RR Regeneration Rate; VBG Vertical Bone Gain; Complic. Complications