Skip to main content

Table 4 Modified 2 × 2 contingency table of brush biopsies using rigid brush compared to final histologically proven diagnoses

From: Comparison between two cell collecting methods for liquid-based brush biopsies: a consecutive and retrospective study

Cytology

Test: rigid brush

Histology

Positive for malignancy

Negative for malignancy

Total

Positive

77

 

12

 

89

 

Suspicious

15

108

41

187

56

295

Doubtful

16

 

134

 

150

 

Negative

5

 

1052

 

1057

 

Total

113

 

1239

 

1352

 

Overall accuracy

85.80%

    Â