Skip to main content

Table 1 Cases description, implant dimensions, and follow-up time

From: Socket shield technique and delayed implant placement in maxilla: a series of five case reports

Patient no

Age (years)

Sex

Tooth type

Extraction cause

Facial plate thickness (mm)

Gingival biotype

Smile line

Socket reentry time (months)

Inserted implant (AnyRidge)

Loading time (months)

Overall follow-up (months)

1

31

M

2nd premolar

Deep subgingival caries

1

Thick

Low

5

3.5 × 15

15

19

2

29

F

2nd premolar

Deep subgingival caries

0.9

Thick

Low

6

3.5 × 11.5

13

17

3

45

F

Canine

Horizontal fracture

1

Thick

High

3

3.5 × 15

3

5

4

30

F

Lateral incisor

Horizontal fracture

1

Thick

Average

4

3.5 × 15

5

8

5

38

F

Canine

Horizontal fracture

1.1

Thick

Low

4

3.5 × 13

9

12