From: Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study
Material
Modulus of elasticity (MPa)
Poisson's ratio
Compact bone
13,700
0.3
Cancellous bone
7930
Zirconia
200,000
Titanium alloy
110,000
0.33