Skip to main content

Table 3 Compressive strength (MPa) for tested group at 1-day and at 1-month post-photocuring

From: Effect of contamination of bulk-fill flowable resin composite with different contaminants during packing on its surface microhardness and compressive strength: in vitro study

 

One-day

One-month

p-value

n

Mean ± SD

95%CI

n

Mean ± SD

95%CI

Control

5

110.42a ± 15.10

91.68–129.17

5

172.87a ± 31.92

133.24–212.50

0.001

A. Saliva

5

72.45ab ± 11.33

58.39–86.52

5

77.71c ± 42.77

24.60–130.82

0.752

Alcohol

5

104.22a ± 14.62

86.07–122.37

5

122.66b ± 27.70

88.26–157.06

0.751

Gloves powder

5

56.71b ± 16.66

36.02–77.39

5

61.97c ± 13.89

11.09–88.07

0.751

Hemostatic agent

5

91.59ab ± 26.09

59.20–123.98

5

94.55bc ± 24.34

64.34–124.77

0.858

p-value

 

 < 0.001

 

 < 0.001

 
  1. Different superscript letters within each column indicates significant difference (Adjusted p-value, Tukey’s HSD)