Skip to main content
Fig. 3 | BMC Oral Health

Fig. 3

From: Finite element analysis of stress in oral mucosa and titanium mesh interface

Fig. 3

The displacement pattern of all the components under occlusal or labial loading. Light pink regions indicate the keratinized mucosa on titanium mesh (G gingival direction, O occlusal direction, M mesial direction, D distal direction): a the displacement of titanium mesh and screws, b the displacement of graft materials, c the displacement of bone and teeth, and d the displacement of oral mucosa