Skip to main content

Table 4 Comparison of Root mean-squared (RMS) values of precision between models with diastema and edentulous spaces (DEM) and models with crowding (CM) for each 3D printer tested

From: Accuracy (trueness and precision) of 3D printed orthodontic models finalized to clear aligners production, testing crowded and spaced dentition

3D Printers

Groups

N

RMS

SD

RMS Difference (mm)

SE Difference

Significance

(mm)

Asiga Pro 4k65

DEM

10

0,040

0,013

0,001

0,005

NS

CM

10

0,039

0,012

Photon M3

DEM

10

0,095

0,019

0,005

0,01

NS

CM

10

0,100

0,025

Form 3B

DEM

10

0,051

0,016

0,002

0,007

NS

CM

10

0,049

0,014

Vector 3SP

DEM

10

0,048

0,014

0,002

0,006

NS

CM

10

0,050

0,014