Table 7 Maximum modified von Mises stress (mvM) values (MPa) for tooth, cement lines, flowable composite for tested restorative materials

From: Impact of different CAD/CAM materials on internal and marginal adaptations and fracture resistance of endocrown restorations with: 3D finite element analysis

Structure (Material/Tissue)

Maximum modified von Mises stress (mvM)

Vita-Enamic

Nacera Hybrid

Zirconia

PEKK

Tooth

24.2

16.3

11.4

93.1

Cement line

29.6

20.4

13.6

64.5

Flowable composite

15.4

13.3

11.6

58.4