Skip to main content

Table 10 UL1 Comparison of TC-85 groups

From: Forces and moments generated during extrusion of a maxillary central incisor with clear aligners: an in vitro study

Force

No attachment

Attachment

Pressure columns

P-valuea

P-valueb

P-valuec

Mean

Std Dev

Mean

Std Dev

Mean

Std Dev

Fx (N)

1.40

0.32

0.51

0.36

1.19

0.27

 < 0.001

 < 0.001

 < 0.001

Fy (N)

-0.67

0.28

-0.49

0.39

-0.48

0.36

 < 0.001

 < 0.001

 < 0.001

Fz (N)

0.41

0.17

0.39

0.29

0.45

0.16

 < 0.001

 < 0.001

 < 0.001

Mx (Nmm)

4.68

2.09

5.47

2.70

5.59

2.19

 < 0.001

 < 0.001

 < 0.001

My (Nmm)

6.98

1.52

1.00

2.77

6.98

1.61

 < 0.001

 < 0.001

 < 0.001

Mz (Nmm)

-14.04

2.93

-6.45

6.83

-12.46

3.20

 < 0.001

 < 0.001

 < 0.001

  1. P-valuea is a comparison between control vs attachment
  2. p-valueb is a comparison between attachment vs pressure columns
  3. P-valuec is a comparison between control vs pressure columns