Skip to main content

Table 7 UR1 Pressure column groups comparison by material type

From: Forces and moments generated during extrusion of a maxillary central incisor with clear aligners: an in vitro study

Force

ATMOS®

TC-85

Zendura FLX®

P-value1

P-value2

P-value3

Mean

Std Dev

Mean

Std Dev

Mean

Std Dev

Fx (N)

1.51

1.28

0.15

0.16

2.43

0.36

 < 0.001

 < 0.001

 < 0.001

Fy (N)

-4.77

3.71

-2.59

1.20

-0.54

1.66

 < 0.001

 < 0.001

 < 0.001

Fz (N)

1.91

2.71

-0.63

0.32

0.00

0.64

 < 0.001

 < 0.001

 < 0.001

Mx (Nmm)

-8.85

12.15

-6.06

5.90

-1.41

6.63

 < 0.001

 < 0.001

 < 0.001

My (Nmm)

-2.96

17.53

0.52

1.95

0.88

4.80

 < 0.001

 < 0.001

 < 0.001

Mz (Nmm)

78.64

51.26

34.34

13.30

21.04

19.66

 < 0.001

 < 0.001

 < 0.001

  1. P-value1 is a comparison between ATMOS® vs TC-85
  2. P-value2 is a comparison between TC-85 vs Zendura FLX®
  3. P-value3 is a comparison between ATMOS® vs Zendura FLX®