From: Detection of the pathological exposure of pulp using an artificial intelligence tool: a multicentric study over periapical radiographs
IoU = 0.5
TP(labels
FP(labels)
FN(labels)
Precision
Recall
F1-score
mAP@.5(AUC)
mAP@.5.95
All
691
56
61
0.928
0.918
0.922
0.956
0.613
Exposed
277
20
23
0.93
0.92
0.925
0.97
0.665
Not exposed
41,435
35
38
0.926
0.916
0.921
0.943
0.56