Skip to main content

Table 2 Crown occlusion adjustment in test and control groups

From: Auxiliary occlusal devices for IO scanning in a complete digital workflow of implant-supported crowns: a randomized controlled trial

  

Test

Control

p-value

  

Mean ± SD (95%CI)

Mean ± SD (95%CI)

Maximum Occlusion Adjustment (µm)

Mesial Crown

263.74 ± 132.57 (179.51, 347.97)

468.82 ± 208.54 (336.31, 601.32)

 

Distal Crown

295.59 ± 90.45 (238.12, 353.06)

490.36 ± 207.26 (358.67, 622.04)

 

Mean

279.67 ± 112.17 (232.30, 327.03)

479.59 ± 203.63 (393.60, 565.57)

< 0.001

Area of Occlusion Adjustment (mm2)

Mesial Crown

10.48 ± 9.13 (4.68, 16.28)

25.16 ± 15.37 (15.41, 34.92)

 

Distal Crown

13.76 ± 11.91 (6.19, 21.89)

25.08 ± 13.50 (16.50, 33.66)

 

Mean

12.12 ± 10.51 (7.68, 16.56)

25.12 ± 14.14 (19.15, 31.09)

0.013

  1. SD: Standard deviation; 95% CI: 95% Confidence interval. A linear mixed model was conducted to evaluate fixed effect of groups and crown positions on maximum occlusion adjustment and area of occlusion adjustment of crowns