Skip to main content

Adhesion of Candida Albicans to digital versus conventional acrylic resins: a systematic review and meta-analysis

Abstract

Background

The present systematic review and meta-analysis investigated the available evidence about the adherence of Candida Albicans to the digitally-fabricated acrylic resins (both milled and 3D-printed) compared to the conventional heat-polymerized acrylic resins.

Methods

This study followed the guidelines of the Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA). A comprehensive search of online databases/search tools (Web of Science, Scopus, PubMed, Ovid, and Google Scholar) was conducted for all relevant studies published up until May 29, 2023. Only in-vitro studies comparing the adherence of Candida albicans to the digital and conventional acrylic resins were included. The quantitative analyses were performed using RevMan v5.3 software.

Results

Fourteen studies were included, 11 of which were meta-analyzed based on Colony Forming Unit (CFU) and Optical Density (OD) outcome measures. The pooled data revealed significantly lower candida colonization on the milled digitally-fabricated compared to the heat-polymerized conventionally-fabricated acrylic resin materials (MD = − 0.36; 95%CI = − 0.69, − 0.03; P = 0.03 and MD = − 0.04; 95%CI = − 0.06, − 0.01; P = 0.0008; as measured by CFU and OD respectively). However, no differences were found in the adhesion of Candida albicans between the 3D-printed digitally-fabricated compared to the heat-polymerized conventionally-fabricated acrylic resin materials (CFU: P = 0.11, and OD: P = 0.20).

Conclusion

The available evidence suggests that candida is less likely to adhere to the milled digitally-fabricated acrylic resins compared to the conventional ones.

Peer Review reports

Background

The rapid and huge progress in all aspects of technology imposes a growing interest in using computer-aided design and computer-aided manufacturing (CAD/CAM) for fabricating removable digital dentures [1]. According to the Glossary of Digital Dental Terms, “digital denture” refers to a dental prosthesis fabricated through automation using CAD/CAM and computer-aided engineering [2]. Digital dentures can be fabricated using subtractive manufacturing, whereby the bulk denture resin is removed according to the designated denture in a milling machine [3]. In contrast, additive manufacturing involves incrementing the resin as layers with photopolymerization depending on the type of 3D printer, either by stereolithography or digital light processing (DLP) [4, 5]. Despite the differences in fabrication techniques, the chemical composition of the resins used is almost similar [6].

Studies have reported that the application of milling and 3D printing in the fabrication of dentures results in excellent surface adaptation, comparable strength to the conventional ones, and good clinical outcomes [7], with high levels of patient satisfaction [8]. According to the dental literature, the milled resin exhibits more stability and less polymerization shrinkage compared to the 3D-printed resin [9]. The milled acrylic resin is made of pre-polymerized blocks which minimize or even lack the after-processing shrinkage, while in the 3D-printed resin, the polymerization process may be less controllable, which can lead to variations in shrinkage. In addition, the surface properties of the milled dentures are superior to those of the 3D-printed dentures [10]. However, several factors such as the type of a printer, build angulation, and a layer thickness may affect the surface and mechanical properties [11].

Denture-related stomatitis (DS) is a primary concern when it comes to removable prostheses. The prevalence of DS among denture wearers ranges from 15 to 70% [12]. It is more common among the elderly population, and can, interestingly, increase the risk of systemic infection [13]. DS is a multifactorial disease with the predominantly associated factors are, among others, poor denture hygiene, continuous night-time denture wearing, and Candida infection [12]. DS can develop faster than previously reported, even with new dentures; continued denture wearing and poor cleaning of dentures revealed a considerable impact on DS onset, with Candida albicans (C. albicans) as the most identified kind of yeast [14]. Indeed, Candida adhesion and proliferation on the surface of the acrylic denture base can lead to inflammation of the oral tissue, especially of the denture-fitting surface [15, 16]. This issue is controversial; however, recent studies suggested that the adherence of multiple species of microbes on the denture surface leads to the pathogenesis of denture stomatitis [17,18,19].

Candida albicans is the key pathogen implicated in the development of denture stomatitis [20, 21]. In this context, several studies have reported lower Candida adhesion to milled dentures compared to the conventional ones [18, 22, 23], with inconsistent results regarding the 3D-printed dentures [19, 24,25,26]. Other studies suggested that C. albicans has almost similar adherence on the 3D-printed and the milled denture surfaces [11, 18]. However, it is worth to note that the milled dentures have less adherence affinity, thus reducing the risk of DS occurrence [27], while the adherence affinity is high on the 3D-printed dentures [28], especially if the print orientation is not optimized, thus increasing the risk of DS [11]. Collectively, although the digital dentures have shown promising results, the long-term outcomes and clinical performance are still lacking. Moreover, since the digital dentures are new to the field, there has been no concrete evidence on the extent of Candida adherence on their surfaces so far [22, 23, 27,28,29,30,31,32,33,34,35,36]. Therefore, this systematic review and meta-analysis aimed to assess the available evidence regarding Candida adherence to the digitally-fabricated acrylic resins (both milled and 3D-printed) in comparison to conventional heat-polymerized acrylic resins.

Methodology

The registration and focused question

This systematic review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines [37]. The protocol of this systematic review was registered in the PROSPERO registry (ID: CRD42023390907). The focused research question is, “Does digital acrylic resin (milled and 3D-printed) have higher fungal adherence affinity than conventional heat-polymerized acrylic resins?”

Eligibility criteria

The inclusion criteria were as follows: a) Controlled in-vitro studies that compared candidal colonization on the digital (milled or 3D-printed) acrylic with the conventional heat-polymerized acrylic resins, and b) Articles published in English with no time limits. The exclusion criteria were: review articles, editorials, commentaries, abstracts, case reports, uncontrolled studies, in-vivo studies, and studies published in a language other than English. The PICOS framework was used to formulate the research question as follows: Population (P): digital acrylic resin (milled or 3D-printed); Intervention (I): exposure to candidal culture; Comparator (C): conventional heat-polymerized acrylic resin; Outcome (O): candida growth; and study design (S): a controlled in-vitro study.

Search strategy and information sources

Two investigators conducted an independent, yet meticulous and thorough search of multiple online databases/search engines (Web of Science, Scopus, PubMed, Ovid, and Google Scholar) for all relevant studies published up until May 29, 2023. Different combinations of the following keywords were used with the aid of the Boolean operators (AND, OR): (“CAD-CAM denture” OR “CAD/CAM denture” OR “digital denture” OR “3d printed denture” OR “printed denture” OR “printed resin” OR “milled denture” OR “milled resin” OR “conventional heat-polymerized acrylic resin” OR “conventional resins” OR “conventional denture” OR “heat-polymerized acrylic resin” OR “heat-polymerized acrylic denture”) AND (“antimicrobial” OR “adhesion” OR “antifungal” OR “candida” OR “colonization”). Table 1 in Supplementary file 1 provides a detailed description of the search strategy in the different databases/search engines.

Screening and selection process

The studies retrieved were exported to the EndNote program, and the duplicates, if any, were removed. Two investigators independently screened the remaining studies, based on the title and abstract, to identify the relevant articles. The full-texts of the potentially relevant studies were retrieved and assessed for inclusion. In addition, a manual search of the reference lists of the included studies was performed to identify any additional relevant studies.

Data extraction

Two reviewers extracted the following data independently: the name of the author(s), publication year, type of acrylic resins used, number of samples per group, dimensions of the specimen, type, and number of microbial isolates, time, temperature, and concentration of candidal exposure, and the measurement method of efficiency. Concerning Wei et al. study [36], the numerical data were extracted from their figures using a semi-automated online tool called “WebPlotDigitizer”, available at https://apps.automeris.io/wpd/ (Supplementary Fig. 1). Concerning Koujan et al. study [27], the standard errors of the means were converted to standard deviations following the formula: \(SE= SD/\sqrt{n}\). With regard to Linder study [34], the differences between the groups were not reported completely; so that the mean, SD, and N were used for pairwise comparisons between the digital and conventional groups using GraphPad Prism 9.5.0 (GraphPad Software, San Diego, CA, USA) to obtain clear comparison results (Supplementary file 2). The extracted data were then tabulated for further analysis.

Risk of bias assessment

Two reviewers independently and thoroughly assessed the risk-of-bias of the included studies utilizing the QUIN tool. Discrepancies, if any, were resolved by group discussion. The QUIN tool consists of 12 criteria recommended for assessing the risk-of-bias of in-vitro studies conducted in dentistry [38]. According to the nature of the included studies, two criteria, namely “Detailed explanation of sampling technique” and “Randomization”, were excluded as being inapplicable. Each criterion is given a score of 2 points if adequately specified, 1 point if inadequately specified, and 0 points if not specified. The inapplicable criteria were excluded from the calculation. The criteria individual scores were then added to obtain a total score for a given in-vitro study. This total score was recalculated out of 100% according to the following formula:

$$\textrm{Final}\ \textrm{score}=\frac{\textrm{Total}\ \textrm{score}\times 100}{2\times \textrm{number}\ \textrm{of}\ \textrm{criteria}\ \textrm{applicable}}$$

The included studies were qualified as having “low risk of bias”, “medium risk of bias”, or “high risk of bias” if they scored > 70%, from 50 to 70%, or < 50%, respectively.

Statistical analysis

The quantitative analyses were conducted using Review Manager (RevMan) v5.3 software program for Windows. Only studies that used CFU or OD values as outcome measures were included in the analysis. The pooled mean differences (MD) were calculated as a summary estimate between the digital and the conventional resins. According to the type of outcome measure, two separate meta-analyses were conducted; one for the CFU outcomes, and the other for OD outcomes. Additionally, subgroup analysis was utilized for the 3D-printed and milled resins groups separately. The summary estimates were reported along with their corresponding 95% confidence intervals (CIs). Heterogeneity among the studies was evaluated using the χ2 test I2 statistic. A fixed-effect model was applied for insignificant heterogeneity (I2 ≤ 50%), while a random-effect model was used for significant heterogeneity (I2 > 50%). In addition, StataMP-64 was used for Egger’s test to quantitatively identify the publication bias of the included studies. The significance level was set at a P-value < 0.05.

Results

Study selection

Figure 1 depicts the search strategy employed following the PRISMA guidelines. The online search yielded a total of 497 studies; 215 of which were removed owing to being duplicates. Among the remaining 282 studies, 259 were excluded based on screening their titles and abstracts. The full-texts remaining and potentially relevant 23 studies were retrieved and assessed for eligibility. Of those, 14 studies were excluded for various reasons detailed in the Supplementary file 1: Table 2. A manual search yielded an additional 5 articles meeting the inclusion criteria. As a result, 14 studies were included for qualitative analysis, and 11 of which were included in the quantitative analysis.

Fig. 1
figure 1

Flow chart of the search strategy

Characteristics of the included studies

Table 1 presents the general characteristics of the included studies. There were 14 studies, including 35 independent comparison groups, published between 2014 and 2023. Five studies [22, 23, 33, 35, 36] used only milled acrylic resin, two studies [32, 40] used only 3D-printed acrylic resin, while 7 studies [27,28,29,30,31, 34, 39] used both milled and 3D-printed acrylic resins. The sample sizes varied from 4 to 15 bars/discs with different dimensions. Regarding the microbial isolate, 2 studies [22, 33] used four strains of C. albicans, while the other 12 studies [23, 27,28,29,30,31,32, 34,35,36, 39, 40] used only one strain. The measurement methods for the outcomes also varied across the included studies: 7 studies [22, 29,30,31,32, 34, 40] used CFU/ml (or log CFU/ml), 3 studies [27, 33, 39] used OD, and one study [36] used both CFU/ml and OD. Meanwhile, one study each used adhesion percent [35], cell count per field [23], and microbial cell count [28]. The numerical data which extracted from the included studies and utilized for the meta-analyses are shown in Table 2.

Table 1 Characteristics of the included studies
Table 2 The extracted means and SDs of the fungal colonization in different output units (CFU/ml or OD value), and the main conclusions of the studies subjected to quantitative analysis

Qualitative results

The included 14 studies revealed variable results. Four studies [22, 23, 35, 36] showed significantly lower candida colonization on the digital dentures. Three studies [29, 31, 32] reported comparable results. Three studies [28, 30, 39] showed lower candida colonization on the milled digital dentures, but significantly higher candida colonization on the 3D-printed group as compared to the conventional dentures. Two studies [27, 40] reported higher candida colonization in the 3D-printed group than in the conventional group, but one of them reported no significant differences between the milled digital and the conventional groups. One study [33] reported lower candida colonization in the polished milled digital group compared to the conventional group, but no difference was noted between the glazed milled and the conventional group. One study [34] found no significant differences between the milled group and the conventional group, but it revealed significantly lower candida colonization in the 3D-printed groups compared to the conventional (Tables 1 and 2).

Meta-analysis results

Figure 2 shows the meta-analysis model of studies that used CFU/ml as a measurement method of the outcome. There were six studies with 12 independent comparison groups that used the 3D-printed acrylic resins and six studies with 10 independent comparison groups that used the milled acrylic resins. The pooled data regarding comparing the 3D-printed versus the heat-polymerized acrylic resins revealed lower but non-significant candida colonization on the former compared to the latter (MD = − 0.21; 95%CI = − 0.47, 0.05; P = 0.11). However, the pooled data regarding comparing the milled vs. heat-polymerized acrylic resins revealed significant lower candida colonization on the former compared to the latter (MD = − 0.36; 95%CI = − 0.69, − 0.03; P = 0.03). Owing to the high heterogeneity amongst the studies (I2 = 89%; P < 0.00001), the random-effect model was used.

Fig. 2
figure 2

Forest plot of the pooled data for the included studies that used log CFU/ml as measurement unit

Figure 3 shows the meta-analysis model of studies that used OD value as a measurement method of the outcome. There were only two studies with two independent comparison groups that used the 3D-printed acrylic resin. The results of these studies revealed insignificant but higher candida colonization on the 3D-printed acrylic resin compared to the heat-polymerized acrylic resin (MD = 0.40; 95%CI = − 0.21, 1.02; P = 0.11). There were four studies with 11 independent comparison groups that used the milled acrylic resin. The pooled data revealed a significantly lower candida colonization in the milled resin group compared to the heat-polymerized acrylic resin group (MD = − 0.04; 95%CI = − 0.06, − 0.01; P = 0.0008). Owing to the high heterogeneity amongst the studies (I2 = 97%; P < 0.00001), the random-effect model was used.

Fig. 3
figure 3

Forest plot of the pooled data for the included studies that used OD value as measurement unit

Publication Bias

As shown in Fig. 4, the qualitative (Fig. 4A) and quantitative (Fig. 4B) analyses revealed no publication bias among the studies that used CFU/ml (P = 0.910, Egger’s test). Similarly, regarding the studies that used OD value, no publication bias was found (Fig. 5A and B) (P = 0.070, Egger’s test).

Fig. 4
figure 4

Publication bias (A) and Egger’s test (B) for the included studies that used log CFU/ml as measurement unit

Fig. 5
figure 5

Publication bias (A) and Egger’s test (B) for the included studies that used OD value as measurement unit

Quality of the included studies

The quality results of the included studies are presented in Figs. 6 and 7. All the studies included in this systematic review and meta-analysis were found to be of moderate quality, ranging from 50 to 70%. The majority of the methodological shortcomings were related to sample size calculation, operator details, outcome assessor details, and blinding of the operator(s), outcome assessor(s), and statistician. Details of the statistical part were also missing from some studies.

Fig. 6
figure 6

Risk of bias summary of the included studies

Fig. 7
figure 7

Risk of bias graph of the included studies

Discussion

While conventional materials and methods have long been used in denture fabrication, recent advances in dental materials and technologies have led to the development of new denture materials and digital fabrication methods [41,42,43]. However, these new materials and methods must demonstrate improved biocompatibility, better mechanical properties, and a less favourable environment for microbial adhesion in order to gain acceptance among dental professionals. In this review, we aimed to systematically summarize the available in-vitro evidence on the potential adhesion of C. albicans to digitally-fabricated acrylic resin materials in comparison to conventional ones. The key findings of our meta-analyses indicate that the adhesion of C. albicans, as measured by CFU or OD values, is lower on the milled digitally-fabricated resin materials compared to the conventionally-fabricated resin materials. This suggests that these digitally-fabricated materials either provide a less favourable environment for C. albicans colonization, or have anti-fungal properties. Regardless of the mechanism, this fact must be emphasized, disseminated among dental professionals, and incorporated into clinical practice.

As we have included studies that compared the same material in both conventional and digital methods, the proposed explanation that the digitally-fabricated resin materials have anti-fungal properties is negated. Yildirim et al. [44] concluded that the adhesion of C. albicans to of the resin surface may be influenced by the physicochemical properties more than the surface roughness. Instead, the mechanical properties of the materials are suspected to be the reason for the difference in C. albicans adhesion. These mechanical properties vary between the conventionally- and the digitally-fabricated dentures, with the latter providing a less favourable environment for C. albicans colonization. Recent systematic reviews have confirmed that many mechanical properties are different between the two methods of denture fabrication, with surface roughness being a key factor that may influence the adhesion of C. albicans. These reviews have shown that the conventionally-fabricated resins have higher surface roughness values than the digitally-fabricated resins [45,46,47]. Moreover, the surface roughness values of the conventionally-fabricated resins were found to be above the threshold value of 0.2 μm [48]. In a recent meta-analysis, three factors were identified as responsible for C. albicans adhesion to denture materials, including surface roughness, wettability (measured as contact angle), and surface free energy [49]. Al-Fouzan et al. [22] stated that “the rougher the surface, the greater the Candida colonization will be.” However, there is a significant debate regarding the effects of these factors [50,51,52,53]. Other factors including continued denture wearing, poor cleaning of dentures, non-brushing of tongues, as well as sleeping with dentures are also contributing factors to C. albicans adhesion to dentures [14, 54].

Given that the surface porosity and roughness of the acrylic resin are considered responsible factors for C. albicans adhesion, Gauch et al. [55] argued that denture surfaces could be considered an infection source. In fact, many studies have reported a strong positive correlation between C. albicans adhesion and the surface roughness of denture base polymers [23, 56], although one recent study contradicted such results [40]. Based on many previous scanning electron microscope studies, the conventionally-fabricated resin showed a more porous surface and multiple surface irregularities than CAD/CAM-fabricated resin [23, 36]. The presence of such irregularities, porosity, and/or imperfections on a given surface of a dental device enhances microbial accumulation, even when it is clean [57]. As mentioned earlier, a threshold of ≤0.2 μm is recommended in order to prevent the formation of biofilm on any dental hard and prosthetic surfaces [48].

The findings of the present review are important from a clinical point of view. The milled dentures often have smoother and more polished surfaces than conventionally-fabricated dentures. This, in turn, reduces the potential for Candida adherence. Furthermore, milled dentures are less porous and more resistant to moisture absorption compared to the conventionally-fabricated dentures, potentially reducing the favourable conditions for Candida growth. Moreover, better retention and stability are expected due to the precision and improved fit of the milled dentures. Collectively, this helps to reduce the likelihood of micro-movements that may cause friction and irritation, which in turn may create opportunities for Candida to colonize and adhere.

The current systematic review has both strengths and weaknesses. One of the strengths was focusing on in-vitro studies. Including all studies since inception date was another point of strength. Updating the search and conducting manual search in the references of the potential studies was a strong point ensuring covering all the potential studies. Also, the review included studies that assessed one type of material using different fabrication technologies and provided information on the effects of fabrication rather than solely on material types or ingredients. The tool used to assess the quality of the included studies is also robust, representing a strength aspect of the study. The quality of all included studies was moderate. Thereby, the overall evidence of the current study might be affected (downgraded). Accordingly, following a thorough, standardized, precise, and detailed methodology is highly recommended in future studies. However, one of the limitations of this review was that it only included studies published in English, which may have missed valuable information in other languages. Although the qualitative and quantitative tests, Funnel plot and Egger’s test, respectively, revealed no publication bias, this cannot be considered conclusive, especially with a few studies included. Therefore, the potential publication bias might be considered to exist, which represents one of the limitations of the current study. The heterogeneity among the included studies was relatively high. This heterogeneity might be due to the different sample sizes, different dimensions and shapes of the specimens, or the different exposure times to the candida culture among the included studies. Additionally, we tried our best to extract the numerical data from some of the included studies using the relevant software or formula; however, there were three studies that lacked the adopted quantitative data, and thus were excluded from the meta-analysis, which in turn could limit the conclusive evidence of this review. Yet, owing to some methodological limitations of the included studies, more robust in-vitro studies, along with well-designed clinical studies are highly recommended to discern the available evidence.

Conclusion

In conclusion, the limited available evidence suggests that the milled digitally-fabricated acrylic resins provide less adhesion environment to C. albicans compared to the conventionally-fabricated materials. Moreover, in cases where a digitally-fabricated denture is the preferred choice, the recommendation leans toward the milled denture over the 3D-printed one.

Availability of data and materials

All data generated or analyzed during this study are already included.

Abbreviations

PRISMA:

Preferred Reporting Items for Systematic Review and Meta-analyses

C. albicans :

Candida Albicans

DS:

Denture-related Stomatitis

CFU:

Colony Forming Unit

OD:

Optical Density

CAD/CAM:

Computer-Aided Design/Computer-Aided Manufacturing

MD:

Mean Difference

CI:

Confidence Interval

QUIN:

Quality Assessment Tool For In Vitro Studies

ID:

Identification

MS:

Microsoft

SPSS:

The Statistical Package for the Social Sciences

References

  1. Ishida Y, Kuwajima Y, Kobayashi T, Yonezawa Y, Asack D, Nagai M, Kondo H, Ishikawa-Nagai S, Da Silva J, Lee SJ. Current implementation of digital dentistry for removable prosthodontics in US dental schools. Int J Dent. 2022;2022:7331185.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Grant GT, Campbell SD, Masri RM, Andersen MR. Glossary of digital dental terms, 2nd edition: American College of Prosthodontists and ACP Education Foundation. J Prosthodont. 2021;30(S3):172–81.

    Article  Google Scholar 

  3. Kattadiyil MT, Goodacre CJ, Baba NZ. CAD/CAM complete dentures: a review of two commercial fabrication systems. J Calif Dent Assoc. 2013;41(6):407–16.

    PubMed  Google Scholar 

  4. Villias A, Karkazis H, Yannikakis S, Theocharopoulos A, Sykaras N, Polyzois G. Current status of digital complete dentures technology. Prosthesis. 2021;3:229–44.

    Article  Google Scholar 

  5. Schweiger J, Stumbaum J, Edelhoff D, Güth JF. Systematics and concepts for the digital production of complete dentures: risks and opportunities. Int J Comput Dent. 2018;21(1):41–56.

    PubMed  Google Scholar 

  6. Srinivasan M, Chien EC, Kalberer N, Alambiaga Caravaca AM, Castelleno AL, Kamnoedboon P, Sauro S, Özcan M, Müller F, Wismeijer D. Analysis of the residual monomer content in milled and 3D-printed removable CAD-CAM complete dentures: an in vitro study. J Dent. 2022;120:104094.

    Article  PubMed  Google Scholar 

  7. Alhallak K, Hagi-Pavli E, Nankali A. A review on clinical use of CAD/CAM and 3D printed dentures. Br Dent J. 2023. Epub ahead of print. https://doi.org/10.1038/s41415-022-5401-5.

  8. Mubaraki MQ, Moaleem MMA, Alzahrani AH, Shariff M, Alqahtani SM, Porwal A, Al-Sanabani FA, Bhandi S, Tribst JPM, Heboyan A, et al. Assessment of Conventionally and Digitally Fabricated Complete Dentures: A Comprehensive Review. Materials (Basel, Switzerland). 2022;15(11).

  9. Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent. 2013;109(6):361–6.

    Article  PubMed  Google Scholar 

  10. Kraemer Fernandez P, Unkovskiy A, Benkendorff V, Klink A, Spintzyk S. Surface characteristics of milled and 3D printed Denture Base materials following polishing and coating: an in-vitro study. Materials (Basel, Switzerland). 2020;13(15).

  11. Goodacre BJ, Goodacre CJ. Additive manufacturing for complete denture fabrication: a narrative review. J Prosthodont. 2022;31(S1):47–51.

    Article  PubMed  Google Scholar 

  12. Gendreau L, Loewy ZG. Epidemiology and etiology of denture stomatitis. J Prosthodont. 2011;20(4):251–60.

    Article  PubMed  Google Scholar 

  13. Al-Maweri SA, Al-Jamaei AA, Al-Sufyani GA, Tarakji B, Shugaa-Addin B. Oral mucosal lesions in elderly dental patients in Sana’a, Yemen. J Int Soc Prev Community Dent. 2015;5(Suppl 1):S12–9.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Mousa MA, Lynch E, Kielbassa AM. Denture-related stomatitis in new complete denture wearers and its association with Candida species colonization: a prospective case-series. Quintessence Int (Berlin, Germany : 1985). 2020;51(7):554–65.

    Google Scholar 

  15. Ramage G, Tomsett K, Wickes BL, López-Ribot JL, Redding SW. Denture stomatitis: a role for Candida biofilms. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2004;98(1):53–9.

    Article  PubMed  Google Scholar 

  16. Yarborough A, Cooper L, Duqum I, Mendonça G, McGraw K, Stoner L. Evidence regarding the treatment of denture stomatitis. J Prosthodont. 2016;25(4):288–301.

    Article  PubMed  Google Scholar 

  17. Arutyunov S, Kirakosyan L, Dubova L, Kharakh Y, Malginov N, Akhmedov G, Tsarev V. Microbial adhesion to dental polymers for conventional, computer-aided subtractive and additive manufacturing: a comparative in vitro study. J Funct Biomater. 2022;13(2).

  18. Di Fiore A, Meneghello R, Brun P, Rosso S, Gattazzo A, Stellini E, Yilmaz B. Comparison of the flexural and surface properties of milled, 3D-printed, and heat polymerized PMMA resins for denture bases: an in vitro study. J Prosthodont Res. 2022;66(3):502–8.

    Article  PubMed  Google Scholar 

  19. Schubert A, Bürgers R, Baum F, Kurbad O, Wassmann T. Influence of the manufacturing method on the adhesion of Candida albicans and Streptococcus mutans to Oral splint resins. Polymers. 2021;13(10).

  20. Tsui C, Kong EF, Jabra-Rizk MA. Pathogenesis of Candida albicans biofilm. Pathog Dis. 2016;74(4):ftw018.

    Article  PubMed  PubMed Central  Google Scholar 

  21. Le Bars P, Kouadio AA, Bandiaky ON, Le Guéhennec L, de La Cochetière MF. Host's immunity and Candida species associated with denture stomatitis: a narrative review. Microorganisms. 2022;10(7).

  22. Al-Fouzan AF, Al-Mejrad LA, Albarrag AM. Adherence of Candida to complete denture surfaces in vitro: a comparison of conventional and CAD/CAM complete dentures. J Adv Prosthodont. 2017;9(5):402–8.

    Article  PubMed  PubMed Central  Google Scholar 

  23. Murat S, Alp G, Alatalı C, Uzun M. In vitro evaluation of adhesion of Candida albicans on CAD/CAM PMMA-based polymers. J Prosthodont : Off J Am Coll Prosthodont. 2019;28(2):e873–9.

    Article  Google Scholar 

  24. Li P, Fernandez PK, Spintzyk S, Schmidt F, Beuer F, Unkovskiy A. Effect of additive manufacturing method and build angle on surface characteristics and Candida albicans adhesion to 3D printed denture base polymers. J Dent. 2022;116:103889.

    Article  CAS  PubMed  Google Scholar 

  25. Shim JS, Kim JE, Jeong SH, Choi YJ, Ryu JJ. Printing accuracy, mechanical properties, surface characteristics, and microbial adhesion of 3D-printed resins with various printing orientations. J Prosthet Dent. 2020;124(4):468–75.

    Article  CAS  PubMed  Google Scholar 

  26. Yacob N, Ahmad NA, Safii SH, Yunus N, Razak FA. Is microbial adhesion affected by the build orientation of a 3-dimensionally printed denture base resin? J Prosthet Dent. 2023; (In Press).

  27. Koujan A, Aggarwal H, Chen PH, Li Z, Givan DA, Zhang P, Fu CC. Evaluation of Candida albicans adherence to CAD-CAM milled, 3D-printed, and heat-cured PMMA resin and efficacy of different disinfection techniques: an in vitro study. J Prosthodont : Off J Am Coll Prosthodont. 2022;32.

  28. Meirowitz A, Rahmanov A, Shlomo E, Zelikman H, Dolev E, Sterer N. Effect of Denture Base fabrication technique on Candida albicans adhesion in vitro. Materials (Basel, Switzerland). 2021;14(1).

  29. Alfouzan AF, Tuwaym M, Aldaghri EN, Alojaymi T, Alotiabi HM, Taweel SMA, Al-Otaibi HN, Ali R, Alshehri H, Labban N. Efficacy of denture cleansers on microbial adherence and surface topography of conventional and CAD/CAM-processed Denture Base resins. Polymers. 2023;15(2).

  30. Freitas R, Duarte S, Feitosa S, Dutra V, Lin WS, Panariello BHD, Carreiro A. Physical, mechanical, and anti-biofilm formation properties of CAD-CAM milled or 3D printed Denture Base resins: in vitro analysis. J Prosthodont : Off J Am Coll Prosthodont. 2023;32(S1):38–44.

    Article  Google Scholar 

  31. Jung GK. In vitro analysis of attachment of Candida Albicans to Denture Base acrylic resins fabricated by three different methods. Bethesda, Maryland: Uniformed Services University of the Health Sciences; 2020.

    Google Scholar 

  32. Khattar A, Alghafli JA, Muheef MA, Alsalem AM, Al-Dubays MA, AlHussain HM, AlShoalah HM, Khan SQ, AlEraky DM, Gad MM. Antibiofilm activity of 3D-printed nanocomposite resin: impact of ZrO(2) nanoparticles. Nanomaterials (Basel, Switzerland). 2023;13(3).

  33. Larijani M, Zareshahrabadi Z, Alhavaz A, Hajipour R, Ranjbaran A, Giti R, Soltankarimi V, Zomorodian K. Evaluation of Candida albicans biofilm formation on conventional and computer-aided-design/computer-aided manufacturing (CAD/CAM) denture base materials. Curr Med Mycol. 2022;8(3):23–9.

    PubMed  PubMed Central  Google Scholar 

  34. Linder WE II. Evaluation of adherence of Candida albicans to differently manufactured acrylic resin Denture Base materials. The University of North Carolina at Chapel Hill; 2022.

    Google Scholar 

  35. Aa M. Comparison of Candida Albicans adhesion to various Denture Base materials. Tufts University School of Dental Medicine; 2014.

    Google Scholar 

  36. Wei X, Gao L, Wu K, Pan Y, Jiang L, Lin H, Wang Y, Cheng H. In vitro study of surface properties and microbial adhesion of various dental polymers fabricated by different manufacturing techniques after thermocycling. Clin Oral Investig. 2022;26(12):7287–97.

    Article  PubMed  Google Scholar 

  37. Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6(7):e1000097.

    Article  PubMed  PubMed Central  Google Scholar 

  38. Sheth VH, Shah NP, Jain R, Bhanushali N, Bhatnagar V. Development and validation of a risk-of-bias tool for assessing in vitro studies conducted in dentistry: The QUIN. J Prosthet Dent. 2022:S0022-3913(22)00345-6.

  39. Osman RB, Khoder G, Fayed B, Kedia RA, Elkareimi Y, Alharbi N. Influence of fabrication technique on adhesion and biofilm formation of Candida albicans to conventional, milled, and 3D-printed Denture Base resin materials: a comparative in vitro study. Polymers. 2023;15(8).

  40. Teixeira ABV, Valente M, Sessa JPN, Gubitoso B, Schiavon MA, Dos Reis AC. Adhesion of biofilm, surface characteristics, and mechanical properties of antimicrobial denture base resin. J Adv Prosthodont. 2023;15(2):80–92.

    Article  PubMed  PubMed Central  Google Scholar 

  41. Schweiger J, Edelhoff D, Güth JF. 3D printing in digital prosthetic dentistry: an overview of recent developments in additive manufacturing. J Clin Med. 2021;10(9).

  42. Anadioti E, Musharbash L, Blatz MB, Papavasiliou G, Kamposiora P. 3D printed complete removable dental prostheses: a narrative review. BMC Oral Health. 2020;20(1):343.

    Article  PubMed  PubMed Central  Google Scholar 

  43. Mohd Farid DA, Zahari NAH, Said Z, Ghazali MIM, Hao-Ern L, Mohamad Zol S, Aldhuwayhi S, Alauddin MS. Modification of polymer based dentures on biological properties: current update, status, and findings. Int J Mol Sci. 2022;23(18).

  44. Yildirim MS, Hasanreisoglu U, Hasirci N, Sultan N. Adherence of Candida albicans to glow-discharge modified acrylic denture base polymers. J Oral Rehabil. 2005;32(7):518–25.

    Article  CAS  PubMed  Google Scholar 

  45. de Oliveira Limírio JPJ, Gomes JML, Alves Rezende MCR, Lemos CAA, Rosa C, Pellizzer EP. Mechanical properties of polymethyl methacrylate as a denture base: conventional versus CAD-CAM resin - a systematic review and meta-analysis of in vitro studies. J Prosthet Dent. 2022;128(6):1221–9.

    Article  PubMed  Google Scholar 

  46. Srinivasan M, Kamnoedboon P, McKenna G, Angst L, Schimmel M, Özcan M, Müller F. CAD-CAM removable complete dentures: a systematic review and meta-analysis of trueness of fit, biocompatibility, mechanical properties, surface characteristics, color stability, time-cost analysis, clinical and patient-reported outcomes. J Dent. 2021;113:103777.

    Article  CAS  PubMed  Google Scholar 

  47. Jain S, Sayed ME, Shetty M, Alqahtani SM, Al Wadei MHD, Gupta SG, Othman AAA, Alshehri AH, Alqarni H, Mobarki AH, et al. Physical and mechanical properties of 3D-printed provisional crowns and fixed dental prosthesis resins compared to CAD/CAM milled and conventional provisional resins: a systematic review and Meta-analysis. Polymers. 2022;14(13).

  48. Bollen CM, Lambrechts P, Quirynen M. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater : Off Publ Acad Dent Mater. 1997;13(4):258–69.

    Article  CAS  Google Scholar 

  49. Gad MM, Abualsaud R, Khan SQ. Hydrophobicity of Denture Base resins: a systematic review and Meta-analysis. J Int Soc Prev Community Dent. 2022;12(2):139–59.

    Article  PubMed  PubMed Central  Google Scholar 

  50. Pereira-Cenci T, Cury AA, Cenci MS, Rodrigues-Garcia RC. In vitro Candida colonization on acrylic resins and denture liners: influence of surface free energy, roughness, saliva, and adhering bacteria. Int J Prosthodont. 2007;20(3):308–10.

    PubMed  Google Scholar 

  51. Nevzatoğlu EU, Ozcan M, Kulak-Ozkan Y, Kadir T. Adherence of Candida albicans to denture base acrylics and silicone-based resilient liner materials with different surface finishes. Clin Oral Investig. 2007;11(3):231–6.

    Article  PubMed  Google Scholar 

  52. Hahnel S, Ettl T, Gosau M, Rosentritt M, Handel G, Bürgers R. Influence of saliva substitute films on the initial adhesion of Candida albicans to dental substrata prior to and after artificial ageing. Arch Oral Biol. 2010;55(5):391–6.

    Article  CAS  PubMed  Google Scholar 

  53. de Foggi CC, Machado AL, Zamperini CA, Fernandes D, Wady AF, Vergani CE. Effect of surface roughness on the hydrophobicity of a denture-base acrylic resin and Candida albicans colonization. J Investig Clin Dent. 2016;7(2):141–8.

    Article  PubMed  Google Scholar 

  54. Mousa MA, Alam MK, Ganji KK, Khader Y, Lynch E, Kielbassa AM. Prospective case series on possible effects of local factors on the development of halitosis in new complete denture wearers. Quintessence Int (Berlin, Germany : 1985). 2022;53(3):218–25.

    Google Scholar 

  55. Gauch LMR, Pedrosa SS, Silveira-Gomes F, Esteves RA, Marques-da-Silva SH. Isolation of Candida spp. from denture-related stomatitis in Pará, Brazil. Braz J Microbiol : [publ Braz Soc Microbiol]. 2018;49(1):148–51.

    Article  CAS  PubMed  Google Scholar 

  56. da Silva WJ, Leal CM, Viu FC, Gonçalves LM, Barbosa CM, Del Bel Cury AA. Influence of surface free energy of denture base and liner materials on Candida albicans biofilms. J Investig Clin Dent. 2015;6(2):141–6.

    Article  PubMed  Google Scholar 

  57. Verran J, Maryan CJ. Retention of Candida albicans on acrylic resin and silicone of different surface topography. J Prosthet Dent. 1997;77(5):535–9.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

No fund was received for this study.

Author information

Authors and Affiliations

Authors

Contributions

Mohammed Nasser Alhajj: Conceptualization and study design, Data collection, Formal analysis, Writing- Original Draft. Esam Halboub: Data Curation, Formal analysis, Writing- Review & Editing. Norlela Yacob: Data collection, Writing- Original Draft. Sadeq Ali Al-Maweri: Data Curation, Writing- Review & Editing. Asja Celebić: Data Curation, Writing- Review & Editing. Hesham M. Al-Mekhlafi: Data Curation, Writing- Review & Editing. Siti Fauzza Ahmad: Writing- Review & Editing, Supervision. Nosizana Mohd Salleh: Conceptualization and study design, Methodology, Validation, Writing- Review & Editing, Visualization, Supervision, Project administration. All authors read and approved the final version.

Corresponding author

Correspondence to Nosizana Mohd Salleh.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Alhajj, M.N., Halboub, E., Yacob, N. et al. Adhesion of Candida Albicans to digital versus conventional acrylic resins: a systematic review and meta-analysis. BMC Oral Health 24, 303 (2024). https://doi.org/10.1186/s12903-024-04083-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12903-024-04083-2

Keywords