Skip to main content

The remaining dentin thickness investigation of the attempt to remove broken instrument from mesiobuccal canals of maxillary first molars with virtual simulation technique

Abstract

Background

To investigate differences in the estimated minimum remaining dentin thickness (RDT) between periapical radiographs using the paralleling and parallax technique, after simulated removal of broken instrument from the mesiobuccal (MB) canal of maxillary first molar in virtual simulation model. The 3D measurement was taken as the standard for comparison.

Methods

Thirty-six maxillary first molars were scanned by micro-CT and reconstructed as 3-dimensional (3D) model. A virtual fragment of an instrument was created within the MB canal in software. Removal of the broken instrument was simulated in both the 3D and 2D dataset. Then, the models of all specimens were submitted to 2D and 3D measurements for the lowest (RDT) value in each. Differences in the values between the paralleling and parallax radiographic technique and the 3D-RDT value were analyzed with two-way Analysis of Variance. The Intra-class Correlation Coefficient (ICC) was used to assess consistency of the RDT measurements between the two periapical radiographic and techniques and 3D analysis.

Results

There was significant difference between RDT value obtained from the paralleling technique and 3D-RDT. There were no differences between RDT obtained from parallax (angled) technique and 3D-RDT. The ICC of RDT values between paralleling technique and 3D measurement were lower than 0.75. ICC between angled radiographs and 3D technique was close to 0.75. The optimal horizontal angle for the parallax technique was about 21°.

Conclusions

The virtual simulation technique can provide valuable insight into the benefit/risk analysis before removal of a broken instrument. Parallel radiographs overestimate the actual remain dentin thickness in mesiobuccal canals of maxillary first molars, whereas the parallel technique would give a closer estimate to the actual thickness at a projection angle of about 21°.

Peer Review reports

Background

Root canal preparation is an essential stage of root canal treatment aiming to clean and shape the canals thoroughly. The introduction of rotary nickel-titanium (NiTi) endodontic instruments has improved the efficacy of the process compared with manual stainless steel files [1], as well as enhanced the success rate of treatment [2]. There is a concern about the separation of instrument [3], which has been reported to occur most often in the mesiobuccal canal of maxillary molars and mesial canal of mandibular molars, due to their canal curvature and complex anatomy [4]. The presence of a broken fragment would hinder the thoroughly cleaning and shaping of the root canal system, and may affect the long-term prognosis of treatment [5].

In considering the removal of broken instruments, the clinician needs to evaluate the risk and consider the possible complications. Excessive loss of dentin can increase the risk of lateral perforation or root fracture [6]. The remaining dentin thickness (RDT) is probably the most important factor affecting the decision of removing the fragment instrument, as that contributes to the resistance against root fracture [7, 8]. Typically, the RDT is estimated on periapical radiographs. According to Lim and Stock [8], 200 to 300 μm of dentin thickness should be present after preparation, to withstand the compaction forces during obturation to prevent perforation or fracture. If RDT falls below a certain value, it would be risky to attempt removal of the fragment. Instead, one may then attempt to bypass the broken instrument, or to clean/shape and fill the root canal up to the fragment [9]. Earlier studies usually sectioned the tooth to measure the canal wall thickness in cross section [911]. Such method is destructive, and the samples cannot be used for further studies or as their own control. Furthermore, it is not easy to compare the results with other reports, because of the variability of root canal anatomy. Recently, micro-computed tomography (micro-CT) and the technique of virtual simulation provide promising applications in endodontic research [12, 13]. Micro-CT is as a non-destructive method that has been used to investigate the three-dimensional (3D) morphologic features of roots and root canals. Tomographic images are digitally reconstructed in 3 dimensions [14]. Simulated 2-dimensional (2D) radiographs can be generated, based on micro-CT data by a direct ray casting technique in software, without taking a real radiograph [1517]. Thus, one can measure and calculate the dentin thickness from 3D micro-CT data and the 2D simulated radiographs.

Although radiographs are widely used in clinical endodontics, they are not accurate for determining the actual root anatomy, because of distortion and presence of overlapping structures. In addition, film-based radiograph has the limitation of being two-dimensional projection of a three-dimensional object [18]. For instance, the zygomatic process typically overlaps the roots of maxillary first molar. So, some details about the root anatomy can be misinterpreted or lost, which hinder the visualization of the root canal anatomy and any concavities that may be present in the proximal root surface. This may compromise clinical judgment, especially when the decision to remove broken instrument is concerned. There are few reports on the evaluation and calculation of dentin thickness before the removal of broken instrument in maxillary first molars by radiographic means. The purpose of this study was to evaluate the remaining dentin thickness measurements based on paralleling and parallax (angle) radiographic image, versus 3D tomography, after the virtual removal of broken instruments from the mesiobuccal canal of maxillary first molars.

Methods

Thirty-six maxillary first molars were selected from a collection of extracted human teeth from a Chinese population sample based on mature apices without visible apical resorption. After understanding and written consent was obtained from patients, the extracted teeth were collected by the West China Hospital of Stomatology for teaching and research. The present study was approved by the Ethics Committee of the West China Hospital of Stomatology, and the molars were selected from the teeth bank of the hospital. These teeth were ultrasonically cleaned and stored in thymol solution until use. The teeth were scanned by using a micro-CT system (microCT-50, Scanco Medical, Bassersdorf, Switzerland) with an isotropic voxel size of 30 μm. All scanned data were processed on an HP 6600 W workstation [Hewlett Packard, Palo Alto, CA] running Windows 7.

The MeVisLab package (www.mevislab.de/index) (MeVis Medical Solution, Bremen, Germany) was used, which provided a visual data-flow program environment on a graphic user interface [19], to build a virtual simulation platform for the mesiobuccal (MB) canal of all specimens. The steps of the workflow were similar with those described in another study [19], and included the following steps: (i) Build a 3D dataset from the scanned maxillary molar image; (ii) a 3 mm-long apical segment of a size 25, taper 0.06 endodontic instrument was assumed to have fractured in the MB canal and situated at 3 or 5 mm below the orifice; this was created virtually in the 3D reconstructed model (Fig. 1b and c); (iii) the tooth model was rotated at various angles using the “DRR module” to “isolate” the mesiobuccal root by rotating the tooth model so that it was not overlapped by the palatal root; and (iv) simulated x-ray images, either paralleling or angled (parallax), were generated to represent radiographic images obtained clinically with the techniques, respectively (Fig. 2a-d).

Fig. 1
figure 1

a Morphological reconstruction of one maxillary first molar; b & c size 25/.06 NiTi instrument with 3 mm apical segment assumed to be fractured in the mesiobuccal canal with 3 mm and 5 mm away from the canal orifice; d using modified Gates Glidden burs to create a staging platform and CPR ultrasonic tip to trephine dentin a 1.5 mm distance apically from the coronal part of the fragment around the fragment; e access to the fragment at 3 mm; f access to the fragment at 5 mm

Fig. 2
figure 2

Simulated X-ray image by parallel and parallax technique when broken instrument below the orifice 3 mm (a, c) and 5 mm (b, d) and measurement by ImageJ software

Virtual simulation of the removal of the broken fragment

The clinical procedures were simulated in the Mevislab package as follows: First, the tooth model created as in step (i) and (ii) above. Then, a modified Gates Glidden burs #4 was used to prepare, a “staging platform” up to the coronal aspect of the fractured piece; a scaled and dimensionally correct 3D image of the instrument was inserted into the model in software (see Fig. 1d). After that, ultrasonic tips, (CPR number 7, Obtura-Spartan, Fenton, MO, USA)were used to trephine the dentin around the fragment for 1.5 mm along the fragment (Fig. 1d) to allow the broken instrument to “jump out” of the canal or to retrieve it by using a micro-tube instrument removal system (Fig. 1). The most conservative space requirement was assumed in this simulated process: the diameter of the coronal end of the broken instrument (Db) was 0.43 mm for the 0.06 tapered file and the minimum diameter (Dc) of the CPR ultrasonic at 0.4 mm. Therefore, theoretically, the diameter of the trough created by the ultrasonic tip (D = Db + 2Dc) was 1.23 mm. A cylindrical space of this diameter was positioned around the broken instrument uing the “SoTransformerDragger module” of MeVisLab (Fig. 1e and f).

The 2D simulation steps of fragment removal were performed in ImageJ software (http://imagej.nih.gov/ij/). First, simulated radiodgraphs were generated with a direct ray casting technique from the 3D dataset. Then, a rectangle (4.5 mm × 1.23 mm&6.5 mm × 1.23 mm) that corresponded to the space for straight-line access was set in the resultant paralleling and parallax x-ray images. A similar trepan space (1.23 mm diameter) was created by around the fragment (Fig. 2).

Measurement of remaining canal wall thickness

Model dataset of each tooth after the simulation procedure was submitted to 3D measurement in Mevislab. The remaining dentin thickness measurements were made from the root canal wall to the external root surface along the root using the “3D SurfaceDistance module” of the software. These distances were stored in the nodes for color-coding and analysis. A 3D marker was placed on the surface to allow visualization of the dentin thickness there (Fig. 3). A 3D-RDT value was obtained for each tooth.

Fig. 3
figure 3

3D color-coded image of residual dentin thickness distribution around the narrow parallel space in root dentin after created a staging platform when the instrument placed in mesiobuccal canal below the orifice with 3 mm (a) and 5 mm (b) depth

The 2D canal wall thickness was estimated on both the paralleling (Pa-RDT) and parallax radiograph in the ImageJ software. The RDT value was taken as the minimum distance from the side of the rectangle to the external root surface (Fig. 2).

Statistical analysis

The RDT values were submitted to two-way analysis of variance. Then, the 3Dunnett t test was used to identify the differences in RDT between radiographic and actual 3D thickness. Intra-class correlation coefficient (ICC) was used to assess consistency between the radiographic and actual thicknesses. The level of significance was set at p < 0.05. All analyses were performed a statistical package (SPSS 21.0, SPSS Inc., Chicago, IL).

Results

This virtual simulation platform can provide a safe environment for planning the removal of a broken instrument interactively. The often-proposed approach was followed, i.e. by creating a staging platform and then troughing around the fragment. The space created in such process was simulated in both the 2D and 3D datasets. RDT measurements were obtained from different radiographic projections and from the 3D analysis; the mean and standard deviations were deported in Fig. 4.

Fig. 4
figure 4

The means and standard deviations for RDT by different methods. 3D-RDT(=3D remain dentin thickness), Pa-RDT(= remain dentin thickness obtained from parallel technique), An-RDT(= remain dentin thickness obtained from angulated technique), green and blue color were instrument broken 3 mm and 5 mm below the orifice (group 3 mm and group 5 mm)

For the group with fragment 3 mm below orifice, the minimum RDT value obtained from paralleling radiographic technique (1058 ± 216 μm])was significantly greater than that by the parallax (angled) technique (An-RDT) (606 ± 155 μm), as well as the 3D-RDT (581 ± 159 μm) (p < 0.05). For the 5 mm-deep group, the An-RDT (389 ± 126 μm) was only slightly greater than 3D-RDT (368 ± 159 μm). The Pa-RDT was (895 ± 220 μm), which value was significantly greater than the former two (p < 0.05). Considering the effect of fragment location, the minimum RDT of the 3 mm-deep group was generally greater than that with fragments situated deeper (5 mm below the orifice) in the canal. There were no differences between parallax angled radiograph (An-RDT) and 3D-RDT value for both locations (3 mm versus 5 mm below the orifice) of the fragment. The ICC values of remaining dentin thickness measurements between the paralleling technique and the 3D analysis were 0.479 and 0.574 two for the fragment locations, respectively. Noted that both values were lower than 0.75. The ICC between parallax-RDT and 3D analysis were 0.721 and 0.667 for the two locations, which values were close to 0.75.

The average rotation angle from the paralleling technique to obtain a parallax radiograph with unimpeded image of the mesiobuccal root was 21.06 ± 4.34°.

Discussion

In a recent survey conducted in the UK, 85.1 % of general dental practitioners and 94.8 % of endodontists have experienced fracture of endodontic instruments [20]. Instrument fracture often occurs in narrow and curved canals, such as the mesiobuccal canal of maxillary molars [21, 22]. Removing a fractured instrument from the root canal is a demanding task. Sufficient enlargement of the root canal coronal to the fragment is essential for successful retrieval. Usually a staging platform coronal to the fragment is prepared to allow straight-line access and direct sight of the fragment under the operating microscope. This is followed by the application of ultrasonic tips. If the direct application of ultrasonic energy does not loosen the fragment sufficiently to remove it, then there is a need to grab and retrieved the fragment with some variant of micro-tube [23].

Gao et al. [19] reported that the application framework, based on the freeware MeVisLab, enables the 3D reconstruction and measurements of root canal and teeth scanned by micro-CT. The virtual simulation platform can provide a safe environment for planning for the removal of fractured instruments. Virtual digital radiographs can be generated from the reconstructed micro-CT data. This permits an assessment of remaining dentin wall thickness, as estimated by plain radiographs, with the measurement from 3D analysis serving as the standard for comparison. The software platform in 3 dimensions has facilitated the realistic simulation and evaluation of any changes in dentin thickness that occurs in the roots, if the clinical procedure were to be performed. This platform also allows the comparison of dentin wall thickness obtained from radiographs taken different angles. The technique described in our present study allows each root to serve as its own control and overcomes the problem of sample variation. The virtual simulation platform provides useful and intuitive information in education and research, with potential to extend to the clinical situation.

During the removal of any broken instrument, dentin reduction must be done carefully to avoid root perforation. Hence, treatment planning should include a risk assessment. The clinician has to evaluate the options of either attempting to remove the fragment, bypassing it, or leaving the broken fragment inside the root canal. The decision is often based on information about the root canal wall thickness, especially when root fracture or perforation is to be avoided. The risk of the endodontically treated teeth to fracture increases proportionally to the amount of dentin removed [7]. A direct relationship exists between remain dentin thickness and the strength of the root [2426]. Thus, preservation of sound dentin is very important during removal of broken instrument. In previous studies, teeth were sectioned at one or several selected levels of the root with measurements done in 2D in cross sections [11, 27]. Unavoidably, some parts of the root were destroyed during sectioning and could not be assessed. In the present study, all levels of the root were examined in a virtual platform that also permitted the quantification of the radicular wall thickness if an attempt was made for the broken instrument. The images may be color-coded for easy visualization of the result after these manipulations drilling and troughing were carried out in the tooth.

One may argue that cone beam computed tomography (CBCT) is an accurate and noninvasive technique that may be applied in the clinical situation. However, the cost and radiation dose to the patient must be considered. Periapical radiograph is likely to remain as the most important tool in clinical practice, which is a compromise when dentin thickness information is concerned. Raiden et al. [18] and Souza et al. [28] evaluated the post preparation in premolars using paralleling (bucco-lingual) radiographs, and concluded that periapical radiographs after overestimate the actual root canal wall thickness. Our present study supported the finding that paralleling radiographic technique would overestimate the actual RDT. On the other hand, the parallax technique seems give a closer or more accurate estimation of the actual RDT. As the root may display different appearance in varied projection angle, the projected shape and curvature of the mesiobuccal root could influence the measurement on a periapical radiograph. When the beam crosses the tooth at a certain angle (as in a paralleling technique), the tooth appears blurred in the radiograph. Thus, by the angulating the beam, the shape and concavity of the mesiobuccal root may be better visualized. This is reflected in the results that angled film (parallax technique) produced thickness measurement that is close to, but still slightly greater than the actual 3D-RDT. It might be related to the presence of concavities on the distal (or furcal) surface of the mesiobuccal root of maxillary first molars that were not visible radiographically and thus concealed the true distance between the outer root surface and the root canal wall. Simply put, plain radiographs provide an over-optimistic estimation of the dentin root canal wall thickness on the furcal aspect of the mesiobuccal root. Using a parallax technique would help to reduce the discrepancy in the thickness estimation for risk assessment.

For the actual RDT, the coefficient of variation was 0.034 and 0.049 in the two fragment-location groups (3 and 5 mm). When this coefficient was small, that ICC value would not be high [29]. The ICC values of RDT measurement between parallax radiograph and 3D analysis were close to 0.75 in the present study, suggesting that the parallax technique may provide a better prediction of the true thickness. The thicknesses estimated from these two methods were closer to each other, and were significantly different from that obtained from the paralleling radiographs. Thus, an angled radiograph should be taken when an attempt to remove the broken instrument from the MB canal of maxillary molar is contemplated.

Changing the angulation of the radiation source may help in determining the presence of root or strip perforation [30], additional roots, the localization of periradicular pathosis, and other anatomic structures. The parallax radiographs can avoid the problem of overlapping structures to some extent. For instance, the best angle would show the MB root clearly, separate from the distobuccal and palatal root. In the present study, this horizontal offset angle was about 21°. This may be a guide to the radiologist or clinicians when faced with a broken instrument in such a situation. Morphologically, the anatomy of the MB root of maxillary first molar was complex with a high incidence of MB2 canals, isthmuses, accessory canal, apical delta and loop [31]. Root canal curvatures are most pronounced in the MB canal, in which most cases of instrument fracture occur. In the coronal part, the furcal [i.e. distal] wall of the MB root is rather thin and, often, is much thinner than the mesial wall at similar level [32]. Realizing that intraoral radiographs will overestimate the RDT would be helpful for clinicians to make decisions during clinical procedures; the parallax technique is more accurate than paralleling technique in this regard.

Conclusions

In conclusion, based on virtual simulation platform, the minimal remaining dentin thickness after attempt to remove a fracture instrument was affected by the projection angle, the position of the fractured instrument. There was a high risk of perforation in the middle third of the mesiobuccal canal in the maxillary first molar. Although the results from virtual simulation models cannot always completely extrapolate to the in vivo/patient situation, they can provide valuable insight into the benefit/risk analysis before removal of a separated instrument. To evaluate the RDT during remove broken instrument in maxillary first molars, parallel radiographs overestimate actual remain dentin thickness and angulated technique were significantly more accurate than parallel technique when the angle was 21°. It provides reference information for endodontists and radiologists.

Abbreviations

RDT:

Remain dentin thickness

MB:

Mesiobuccal

3D:

3-dimensional

ICC:

Intra-class correlation coefficient

NiTi:

Nickel-titanium

Micro-CT:

Micro-computed tomography

Pa-RDT:

Remain dentin thickness obtained from parallel technique

An-RDT:

Remain dentin thickness obtained from angulated technique

CBCT:

Cone beam computed tomography

References

  1. Schafer E, Schulzbongert U, Tulus G. Comparison of hand stainless steel and nickel-titanium rotary instrumentation: a clinical study. J Endod. 2004;30:432–5.

    Article  PubMed  Google Scholar 

  2. Cheung GS, Liu CS. A retrospective study of endodontic treatment outcome between Nickel-Titanium rotary and stainless steel hand filing techniques. J Endod. 2009;35:938–43.

    Article  PubMed  Google Scholar 

  3. Parashos P, Gordon I, Messer H. Factors influencing defects of rotary Nickel-Titanium endodontic instruments after clinical use. J Endod. 2004;30:722–5.

    Article  PubMed  Google Scholar 

  4. Iqbal MK, Kohli MR, Kim JS. A retrospective clinical study of incidence of root canal instrument separation in an endodontics graduate program: a PennEndo database study. J Endod. 2006;32:1048–52.

    Article  PubMed  Google Scholar 

  5. Spili P, Parashos P, Messer HH. The impact of instrument fracture on outcome of endodontic treatment. J Endod. 2005;31:845–50.

    Article  PubMed  Google Scholar 

  6. Shemesh H, Roeleveld AC, Wesselink PR, Wu MK. Damage to root dentin during retreatment procedures. J Endod. 2011;37:63–6.

    Article  PubMed  Google Scholar 

  7. Pilo R, Corcino G, Tamse A. Residual dentin thickness in mandibular premolars prepared with hand and rotatory instruments. J Endod. 1998;24:401–4.

    Article  PubMed  Google Scholar 

  8. Lim SS, Stock CJ. The risk of perforation in the curved canal: anticurvature filing compared with the stepback technique. Int Endod J. 1987;20:33–9.

    Article  PubMed  Google Scholar 

  9. Souza EM, do Nascimento LM, Filho EMM, Alves CMC. The impact of post preparation on the residual dentin thickness of maxillary molars. J Prosthet Dent. 2011;106:184–90.

    Article  PubMed  Google Scholar 

  10. Zuckerman O, Katz A, Pilo R, Tamse A, Fuss Z. Residual dentin thickness in mesial roots of mandibular molars prepared with Lightspeed rotary instruments and Gates-Glidden reamers. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2003;96:351–5.

    Article  PubMed  Google Scholar 

  11. Lammertyn PA, Rodrigo SB, Brunotto M, Crosa M. Furcation groove of maxillary first premolar, thickness, and dentin structures. J Endod. 2009;35:814–7.

    Article  PubMed  Google Scholar 

  12. Lyroudia K, Mikrogeorgis G, Bakaloudi P, Kechagias E, Nikolaidis N, Pitas I. Virtual endodontics: three-dimensional tooth volume representations and their pulp cavity access. J Endod. 2002;28:599–602.

    Article  PubMed  Google Scholar 

  13. Gao Y, Haapasalo M, Shen Y, Wu H, Jiang H, Zhou X. Development of virtual simulation platform for investigation of the radiographic features of periapical bone lesion. J Endod. 2010;36:1404–9.

    Article  PubMed  Google Scholar 

  14. Li K-Z, Gao Y, Zhang R, Hu T, Guo B. The effect of a manual instrumentation technique on five types of premolar root canal geometry assessed by microcomputed tomography and three-dimensional reconstruction. BMC Med Imaging. 2011;11:11–4.

    Article  Google Scholar 

  15. Li X, Yang J, Zhu Y. Digitally reconstructed radiograph generation by an adaptive Monte Carlo method. Phys Med Biol. 2006;51:2745–52.

    Article  PubMed  Google Scholar 

  16. Pehlivan B, Pichenot C, Castaing M, Auperin A, Lefkopoulos D, Arriagada R, et al. Interfractional set-up errors evaluation by daily electronic portal imaging of IMRT in head and neck cancer patients. Acta Oncol. 2009;48:440–5.

    Article  PubMed  Google Scholar 

  17. Thompson CM, Hamilton CS, Vaarkamp J. Thorax set-up verification with multiple oblique treatment portal images. B J Radiol. 2009;82:950–5.

    Article  Google Scholar 

  18. Raiden G, Koss S, Costa L, Hernandez JL. Radiographic measurement of residual root thickness in premolars with post preparation. J Endod. 2001;27:296–8.

    Article  PubMed  Google Scholar 

  19. Gao Y, Peters OA, Wu H, Zhou X. An application framework of three-dimensional reconstruction and measurement for endodontic research. J Endod. 2009;35:269–74.

    Article  PubMed  Google Scholar 

  20. Madarati AA, Watts DC, Qualtrough AJE. Opinions and attitudes of endodontists and general dental practitioners in the UK towards the intra-canal fracture of endodontic instruments. Part 2. Int Endod J. 2008;41:1079–87.

    Article  PubMed  Google Scholar 

  21. Shen Y, Peng B. Cheung GS-p. Factors associated with the removal of fractured NiTi instruments from root canal systems. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2004;98:605–10.

    Article  PubMed  Google Scholar 

  22. Tzanetakis GN, Kontakiotis EG, Maurikou DV, Marzelou MP. Prevalence and management of instrument fracture in the postgraduate endodontic program at the Dental School of Athens: a five-year retrospective clinical study. J Endod. 2008;34:675–8.

    Article  PubMed  Google Scholar 

  23. Ruddle C. Nonsurgical retreatment. J Endod. 2004;30:827–45.

    Article  PubMed  Google Scholar 

  24. Gutmann JL. The dentin-root complex: anatomic and biologic considerations in restoring endodontically treated teeth. J Prosthet Dent. 1992;67:458–67.

    Article  PubMed  Google Scholar 

  25. Felton DA, Webb EL, Kanoy BE, Dugoni J. Threaded endodontic dowels: effect of post design on incidence of root fracture. J Prosthet Dent. 1991;65:179–87.

    Article  PubMed  Google Scholar 

  26. Sorensen JA, Martinoff JT. Intracoronal reinforcement and coronal coverage: a study of endodontically treated teeth. J Prosthet Dent. 1984;51:780–4.

    Article  PubMed  Google Scholar 

  27. Katz A, Wasenstein-Kohn S, Tamse A, Zuckerman O. Residual dentin thickness in bifurcated maxillary premolars after root canal and dowel space preparation. J Endod. 2006;32:202–5.

    Article  PubMed  Google Scholar 

  28. Souza EM, Bretas RT, Cenci MS, Maia-Filho EM, Bonetti-Filho I. Periapical radiographs overestimate root canal wall thickness during post space preparation. Int Endod J. 2008;41:658–63.

    Article  PubMed  Google Scholar 

  29. Lee J. Evaluating agreement between two methods for measuring the same quantity: a response. Comput Biol Med. 1992;22:369–71.

    Article  PubMed  Google Scholar 

  30. Shemesh H, Cristescu RC, Wesselink PR, Wu MK. The use of cone-beam computed tomography and digital periapical radiographs to diagnose root perforations. J Endod. 2011;37:513–6.

    Article  PubMed  Google Scholar 

  31. Somma F, Leoni D, Plotino G, Grande NM, Plasschaert A. Root canal morphology of the mesiobuccal root of maxillary first molars: a micro-computed tomographic analysis. Int Endod J. 2009;42:165–74.

    Article  PubMed  Google Scholar 

  32. Degerness RA, Bowles WR. Dimension, anatomy and morphology of the mesiobuccal root canal system in maxillary molars. J Endod. 2010;36:985–9.

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

This study was supported by the National Natural Science Foundation of China (No. 81200781 and No.11272226). The authors deny any conflicts of interest related to this study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yuan Gao.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

QY carried out the studies, performed the statistical analysis and drafted the manuscript. YG conceived of the study, DM and XD participated in its design and coordination. GC and YS provided clinical guidance and helped to draft the manuscript. All authors read and approved the final manuscript.

Rights and permissions

Open Access  This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.

The Creative Commons Public Domain Dedication waiver (https://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yang, Q., Cheung, G.SP., Shen, Y. et al. The remaining dentin thickness investigation of the attempt to remove broken instrument from mesiobuccal canals of maxillary first molars with virtual simulation technique. BMC Oral Health 15, 87 (2015). https://doi.org/10.1186/s12903-015-0075-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12903-015-0075-x

Keywords