Skip to main content

Evaluation of rotary file system (Kedo-S-Square) in root canal preparation of primary anterior teeth using cone beam computed tomography (CBCT)-in vitro study

Abstract

Background

In recent years, pediatric endodontics has witnessed various advances including use of rotary files in pulpectomy. This study aimed to comparatively evaluate taper, amount of dentin removal and instrumentation time of the pediatric rotary Kedo-S Square file, hand K-files and H-files in primary canines using cone beam computed tomography (CBCT).

Methods

60 primary canines were randomly assigned into three groups; A1 Kedo-S-Square rotary file (group I), hand stainless steel K file (group II) and hand stainless steel H file (group III). Teeth were mounted in vinyl poly siloxane impression material templates to be scanned before and after instrumentation by CBCT scans using Ondemand 3D software. Shaping ability of the files were evaluated in terms of taper of the canal and amount of dentin remaining of each group. Instrumentation time was recorded using a digital stopwatch.

Results

Kedo-S Square removed a significantly less amount of dentin in both apical (P < 0.002) and coronal thirds (P < 0.014). Taper of the preparations showed significant differences as Kedo-S Square file showed good taper in maximum number of root canals, while maual K- and H-files showed poor taper in maximum number of root canals (P < 0.0001). Rotary Kedo-S Square files required less instrumentation time (P < 0.0001).

Conclusion

The use of rotary Kedo-S Square files resulted in better conservation of tooth structure, superior tapering ability and least instrumentation time compared to hand K- and H-files.

Peer Review reports

Background

Endodontic root canal preparation in primary teeth is considered to be a challenging procedure because of the perplexing anatomy, tortuous course of the canals, dynamic alteration at the root apex, close proximity to the succedaneous tooth bud as well as the perceived difficulties in behavioral management [1]. Pulpectomy is considered the treatment of choice for pulpally involved primary teeth in which the pulpal tissue is infected due to caries or trauma [2].

Biomechanical preparation is one of the most crucial phases of pulpectomy in primary teeth, which are targeted primarily during debridement of the canals [3]. The standardized method for cleaning and shaping of primary teeth was employed using hand files. Despite being commonly used as the most standard and widely accepted method for biomechanical preparation in primary teeth, certain limitations were associated with hand files as being time-consuming and the occurrence of iatrogenic errors such as lateral perforations, zipping, apical blockage, and canal transportation [4].

To overcome these limitations, Ni–Ti rotary files were first introduced in pediatric endodontics by Barr et al. in 2000 through use of Profile 0.04 taper rotary instruments in pulpectomy of primary teeth. It was found to be an efficient technique to debride the uneven walls of primary root canals and produce a uniform root canal shape that ended with a predictable obturation [5]. Crespo et al. concluded that usage of rotary files in deciduous teeth were more efficient in both root canal shaping and preparation time, facilitating higher quality of obturation of the root canal [6].

Rotary instrumentation performed in primary teeth was through use of rotary files designed specifically for permanent teeth until 2016. The taper and length were limitations in using existing rotary systems for permanent teeth when used in primary teeth [7]. This led to the occurrence of lateral perforations in the root surface especially in primary curved rooted canals [8]. This resulted in a great need for the design of an exclusive pediatric rotary file system that could be used in primary teeth [9].

The launch of new exclusive pediatric rotary files into the field of pediatric dentistry, has dramatically transformed the pediatric endodontic field [10]. Kedo files are rotary endodontic files, which are indigenously manufactured and designed for primary teeth in 2016. Kedo Dental is the name of the manufacturer, and the files were produced in Chennai, Tamil Nadu, India. Kedo rotary files include five generations of products, which were launched and are known respectively as [11]: Kedo-S rotary file, Kedo-SG, Kedo-SG blue [12], Kedo-S Square and Kedo-S Plus [13].

Kedo-S Square rotary file has revolutionized the arena of pediatric endodontics as being the first exclusive single pediatric rotary file system. It is the fourth generation of rotary Kedo-S files, which were introduced in 2019. It consists of two files, one file to be used for anterior primary teeth (A1) and one file to be used for posterior primary teeth (P1). It has a dual core made of NiTi heat-treated alloy and coated with titanium—oxide. The A1 Kedo-S Square file is used for preparation of primary incisors and canines. Kedo-S Square rotary files have a unique feature that includes a variably variable taper design that provides the flexibility and efficiency to facilitate consistently successful cleaning and shaping [10].

The two primary reasons of failure of endodontic rotary instrument, as proven by Sattapan et al. [14], are an excessive torsional and/or flexural load that generates stresses that exceed the elastic deformation capacity of the instrument, causing it to first deform plastically and then fracture. When the tip of the instrument binds in the root canal while the shank continues to rotate, torsion fatigue results [15]. Many variables impact the resistance of rotary instruments to torsional loads, including those linked to clinical use and those connected to the manufacturing process, in addition to the influence of flexural stresses [16]. Clinical use of files include the technique of instrumentation, type of motion used and extension of the access cavity5.features of the files itself are related to the manufacturing process such as type of alloy, heat treatment, surface treatment, cross sectional design, shaft length, tip size, pitch and taper [17,18,19,20].

Numerous methods have been used by researchers to assess the shaping ability of endodontic instruments including radiography, histological sectioning, electron microscopy, stereomicroscopy, computed tomography (CT), cone-beam CT (CBCT) and micro CT. CBCT is a novel noninvasive 3D digital imaging approach, which was used in this study to avoid the reported shortcomings associated with sectioning techniques and two-dimensional radiography [21].

No published scientific studies have evaluated the shaping effectiveness of the recently introduced Kedo-S Square rotary file. Therefore, the aim of the present study was to assess the shaping ability of the Kedo-S Square file in root canal preparation of primary canines in comparison to conventional hand K- and H-files through evaluation of the taper of the canals, residual dentin thickness and assessment of instrumentation time using CBCT.

Material and methods

This in vitro study was conducted in the faculty of Dentistry, Alexandria University, Pediatric Department of Alexandria University and in a Dental Imaging Center, Alexandria. Ethical approval for the study was obtained from the Dental Research Ethics Committee, Faculty of Dentistry, Alexandria University, before the start of the study (International Number IORG 0008839, and Ethics Committee Number 0073-09/2019).

Selection and storage of teeth

Sixty primary canines that were serially extracted or retained beyond the age of exfoliation were enrolled in this study. Length of the roots of the canines ranged from 7 to 10 mm or at least two-thirds of the roots were present [22]. Teeth, which had internal or extensive pathological root resorption or had undergone pulpectomy were excluded from the study. The selected teeth were washed and cleaned under running water to remove soft tissue debris. They were stored in sterile distilled water at room temperature until experiments were conducted.

Sample size calculation and randomization

Sample size was estimated based on the following assumptions: confidence level = 95% and study power = 80%. The mean root canal taper difference of the middle third before and after root canal preparation using Kedo-S Square file = 0.1418 mm, while it was 0.0338 mm in the hand K-files group, with pooled standard deviation (SD) = 0.11113 [22]. H-files were assumed to have a similar effect to the K-files but different from the rotary systems used in pediatric endodontics [23]. Sample size was based on the difference between the Kedo-S-Square rotary file system and Hand K-files using the highest SD to account the variability. The minimum sample size was calculated to be 18 teeth per group, and this was increased to 20 to make up for laboratory processing errors.

Randomization was done using Random Allocation Software. Sixty teeth were randomized with equal allocation ratio of 1:1:1 and block size of six. A trial independent individual prepared a computer-generated randomization list, that was kept in an opaque sealed envelope, to allocate teeth that comply with the inclusion criteria to one of three arms.

Grouping

Teeth were allocated to one of the three groups as follows: Group 1 (Rotary A1 Kedo-S Square), Group 2 (hand K-file) and Group 3 (hand H-file).

Preparation of study specimens

The samples in all the groups were mounted in vinyl-polysiloxane impression material (Express™ XT Putty Quick, 3 M/ ESPE, Germany) in 12 acrylic templates. The custom-made acrylic templates were constructed with dimensions less than the field of view (FOV) of the CBCT machine. In order to maintain uniformity in all samples the teeth were placed in the labio-lingual direction where the mesial surface faced the template [24]. Pre-operative images of all the included primary canines were taken using CBCT. The type of CBCT was Sordex Scanora 3DX, made in Finland with 5 × 5 field of view. The software used was OnDemand 3D software (Seoul, Korea). It has the following features: version 1.0, build 1.0.10.7510, × 64 Edition, copyright (c) 2004–2017 Cybermed, and license key 1135113166 [25]. The exposure time was 6 s with an exposure dose 90 kV and 10 mA. The mode of measurements of the cervical, middle and apical thirds were standardized for all teeth specimens [22]. The standardizations were as follows: apical third of the canal was measured at 3 mm from the apex, middle third of the canal was measured at 6 mm from the apex and coronal third of the root canal was measured at 9 mm from the apex.

All the procedures for the three groups were done by a single calibrated operator. Intra-examiner reliability was determined for the six samples used for the pilot study where ICC values for the dentin thickness showed excellent agreement (ICC = 0.948). The mesio-distal tapering had ICC values of 0.780, which indicates good reliability.

All the steps needed to overcome any sort of bias were taken into consideration to standardize the parameters between the three groups. A No. 4 round carbide bur (Komet, Germany) was used on a high-speed hand piece under water cooling to remove the enamel and dentin layer or superficial caries if present. The endodontic access opening was prepared using No.330 pear shaped bur (Komet, Germany). Then No.10 size K file was used to determine the patency of the canals. The working length was kept 1 mm short of the apical foramen.

Group 1: The root canals were instrumented with the Rotary A1 Kedo-S Square file system (Reeganz Dental Care Pvt. Ltd. India) till the entire working length was covered in a lateral brushing motion 1–2 times in each tooth with X-Smart endodontic motor in a clockwise rotation motion (Dentsply, Wave one, Germany) at 300 rpm and 2.2 N cm torque. The A1 file is color coded with green and black bands on the handle with a tip diameter of 0.38 mm [10].

The rotary instrument was preceded by hand instrument K-file size No 25 and no pre-flaring was required. In order to maintain uniformity during canal instrumentation each Kedo-S Square file was used on up to 5 teeth, although it could be used on up to 12 teeth (nearly 36 canals) as per the manufacturer’s recommendation [26].

Group 2: The root canals were manually prepared with 21 mm stainless steel K-files 0.02 taper from size #15 and the final size was #40 (Dentsply Maillefer, Ballaigues, Switzerland) using the quarter turn and pull technique.

Group 3: The root canals were manually prepared with 21 mm Stainless steel H-files from size #15 and the final size was #40 (Dentsply Maillefer, Ballaigues, Switzerland) using retraction motion (push and pull) technique.

Each hand file was used on up to five teeth and then changed in order to maintain uniformity during root canal instrumentation [27]. Copious irrigation solution was used in order to totally eliminate necrotic pulpal tissue. This irrigation was standardized to 10 ml of 1% sodium hypochlorite, followed by saline in all groups after each file use during the entire cleaning and shaping procedure. The files were lubricated with Ethylenediaminetetraacetic acid (EDTA gel)(RC-Prep, Premier Dental Products, USA) every time during in biomechanical preparation to avoid instrument fracture and separator deformation [28]. Instrumentation time was recorded in (minutes-seconds) by a trained dental assistant using a digital stopwatch. Instrumentation time is the amount of time needed negotiate and shape the canals after access and determination of working length were done [29].

Scanning procedure

The samples in all the groups were mounted again in the templates in a similar manner and were subjected to CBCT scanning as done preoperatively [27]. Post instrumentation (CBCT) scans were conducted to analyze the internal three-dimensional root canal shapes in the three groups. OnDemand 3D software was used to get sagittal and axial cuts for all the imaged teeth. Standardized measurements were taken to measure the coronal, middle and apical thirds.

Assessment of shaping ability

Shaping ability of the files was evaluated by measurements of the residual dentin thickness from the axial cut of the CBCT in mesial, distal, labial and lingual directions at three different levels, coronal third, middle third, and apical third. Taper of the canal was measured from the sagittal cut of the CBCT in the three predefined positions in the mesio-distal direction [22, 30].

According to Gambill JM et al. [31], the percentage of dentin removed was calculated as (X1 − X2) or (Y1 − Y2), multiplied by 100% and divided by X1 or Y1, depending on the side (X or Y), where X1 is the shortest distance from the outside of the root to the periphery of the non-instrumented canal; X2 is a corresponding similar distance in the respective instrumented root canal; Y1 is the shortest distance from the inside of the root to the periphery of the non-instrumented canal; and Y2 is a corresponding similar distance in the respective instrumented root canal.

Taper of the canals, in the mesio-distal direction, was measured in the three defined levels using the OnDemand software [22, 32].

  1. (i)

    Good taper was identified when there was a progressive reduction from coronal, middle to apical third of the root canal [33, 34].

  2. (ii)

    Poor taper was identified when either there was same or increased readings from coronal, middle to apical third of the root canal [33, 34].

Statistical analysis

Normality was checked using descriptive statistics, plots, and normality tests (Shapiro Wilk test). Means and standard deviations (SD) were calculated for normally distributed variables (Dentin thickness, Mesio-Distal taper and instrumentation duration), in addition to median and interquartile range (IQR) for not normally distributed variables (Percent change).

Taper ability was presented as frequency and percentage as it was dichotomized as: good tapered preparation where the taper of the canal after instrumentation showed a progressive reduction from coronal, middle to apical third of the root canal, and poor tapered preparation where there were either similar or increase in the readings from coronal, middle to apical third of the root canal after instrumentation [32].

Percent change for all variables was calculated according to the following formula: [(values after instrumentation—values before instrumentation)/values before instrumentation) × 100]. Significance level was set at p value < 0.05. Data were analyzed using SPSS for Windows version 25.0.

Results

Regarding the tapering ability, the canal tapers prepared with rotary Kedo-S Square file were more conical compared to the H-and K-files and were significantly different (P < 0.0001) as demonstrated in Fig. 1. The shaping ability was not significantly different amongst the hand files. Taper of the canal preparation was significantly better using the Kedo-S Square group file, with a larger number of good tapered preparation 15 (75%) compared with both H-files 5 (25%) and K-files groups 3 (15%), respectively as shown in Fig. 2.

Fig. 1
figure 1

Tapering ability of Kedo-S Square file, K- and H-files

Fig. 2
figure 2

Pictorial representation showing sagittal cut of CBCT: a Pre- and Post-preparation CBCT scan images showing good taper with Kedo-S Square rotary file. b Pre- and Post-preparation CBCT scan images showing poor taper with manual K and H files

The dentin thickness before and after instrumentation is presented in Fig. 3. Comparison of the dentin thickness before and after instrumentation showed significant reduction at all three levels in all groups (P < 0.0001). However, no statistically significant difference in dentin thickness was found between the three groups after instrumentation (P > 0.05).

Fig. 3
figure 3

Mean residual dentin thickness (mm) following use of Kedo-S Square file, K- and H-files before and after instrumentation at different levels

Regarding the median amount of dentin removed, a significant difference was found between the Kedo-S Square file and H- and K-files at the apical level (P = 0.002), and between Kedo file and H-file at the coronal third (P = 0.014). The Kedo-S Square file removed the least amount of dentin (14.02%, 12.75%, 10.84% at the apical, middle, and coronal third, respectively) followed by the K-file group (19.77%, 15.71%, and 13.85%, respectively) and it was the highest in H-file group (21.51%, 16.34%, and 16.90%, respectively) as shown in Table 1/Fig. 4.

Table 1 Comparison of percent reduction in Dentin thickness among three files at different levels
Fig. 4
figure 4

Pictorial representation of axial cut of CBCT for Kedo-S Square, K- and H-file groups: a Pre-operative CBCT image of amount of dentin thickness at apical, middle and coronal thirds, b Post-operative CBCT image of amount of dentin thickness

Instrumentation time elicited with Group 3 H-file (7.67 (2.14) min) was significantly longer than Group 2 K file (5.81 (3.30) min) and was least in Group 1 rotary Kedo-S Square file (2.12 (0.82) min) with (P < 0.0001).

Discussion

Mechanical cleaning of root canals can be done using endodontic broaches, hand files, reamers and nickel‑titanium (Ni–Ti) rotary files. In the field of pediatric endodontics, conventional hand instrumentation has been utilized for decades and is regarded as the gold standard method. Because manual techniques are time-consuming, they frequently cause fatigue in both the operator and the child, which has a significant impact on the aspect of behaviour management in pediatric dentistry. Usage of hand files in preparation of curved canals frequently causes undesirable aberrations such as elbows, zips and danger zones because of their inherent stiffness [35]. Consequently, usage of stainless‑steel files in narrow curved canals is considered to be difficult as apical enlargement is limited, hindering good quality obturation [36].

From the merits of rotary instrumentation are having greater apical enlargement capacity, reducing apical transportation and improving root canal shape over conventional hand files [8]. In deciduous teeth, a larger amount of instrument separation was seen while using permanent rotary systems [34]. In 2017, a survey showed that 66% of dentists needed an exclusive pediatric rotary file for faster preparation and better accessibility [7]. Thus, as recommended by Kuo et al. [37] to modify these files and to design new NiTi rotary files exclusively for primary teeth to accommodate the ribbon shaped canals of primary teeth [4].

The hand 2% tapered files mean that every 1 mm of the file, the taper increases by 0.02 mm. Consequently, the file with a 4% taper will result in better preparation than that of a 2% tapered file. This indicates that the entire length of the file will engage the whole root canal wall, requiring several numbers of files to complete the preparation [38, 39]. The concept of variable tapering root canal preparation was established at Buchanan in 2000, in which the root canal width gradually increases towards the coronal third [40]. Variable-tapered files have different tapers of increasing and decreasing angles along that portion of the file. The variable-tapered file was better at preserving tooth structure than fixed-tapered endodontic files in the mid-root curvature [41].

Regarding tapering ability, this study showed that there was a significant difference in taper of root canal preparation between the three groups as 75% of the Kedo-S Square file preparation, 5% of H-file preparation and 3% of the K-file preparations were identified as good tapered preparations. This can be attributed to the design of the Kedo-S Square files as it has dual cross section and a variable taper corresponding to the anatomy of root canal of primary teeth when compared to the fixed narrow taper hand files. The taper of A1 is 6 to 8%, as the first 5 mm of the file is of 6% taper followed by increase in taper by 7 and 8%. This results in higher cervical enlargement and restricted apical preparation that prevents extrusion of the obturating material [42, 43].

Moreover, its well-designed working length (17 mm length of the file and 13 mm length of the cutting edge) and tip diameter 0.38 mm, avoids the occurrence of lateral perforation at the apical region. The hand K- and H files lack the above-mentioned properties necessary for efficient preparation of canals, which results in reduced number of good taper preparations using the conventional hand files [44].

The dual cross section of Kedo-S Square means that the apical 5 mm of the file has a triangular cross section whereas the rest of the file at the coronal region has a tear drop cross section. This feature enhances tapering toward the apex of the canal. This will create less apical preparation that prevents lateral strip perforation of the canals and more coronal preparation of the root canals, which will permit easy flow of the obturating material into the canals of primary teeth. The tear drop cross section can also be seen in the cross section of hand H-file, which allows for easier pulling capacity motion of the pulp from the canals during instrumentation [9]. H-files have a tear drop shaped cross section and 2% taper that does not provide more conical enlargement [45]. It was also noticed that the hand K- and H-files created irregular non-uniform poorly prepared canals and have limited coronal preparation, which hinders optimal flow of the obturation material [1].

These results resemble the findings of Srinivas et al. [22] who concluded that Kedo-S rotary files creates more conical and good tapered canal preparation when compared to hand K-files. Nahid Razani [33] reported that CBCT assessments showed that better tapered preparations were obtained using M-two rotary files than the hand K-files. No significant difference was found in taper in a study done by Seema et al. [30] wherein they compared hand K files, rotary Prosper files, and rotary Kedo-S files using CBCT. However, 85.7% of rotary ProTaper and 80.95% of Kedo-S preparations showed better taper, but only 71.4% of hand preparations were good preparations.

Sufficient residual dentin thickness is essential to provide enough resistance to lateral and occlusal forces for an endodontically treated tooth. The aggressiveness of the root canal instrument and dentin removal are positively correlated [46]. In this study, Kedo-S Square file seemed to result in more conservative and meticulous removal of dentin. This is desirable to preserve the integrity of thin-walled primary root canals. The percentage of dentin removal was significantly highest with H-file and least in Kedo-S Square file in both apical and coronal thirds.

In the middle third, no significant difference was found between the three groups although hand files had also removed more dentin than the rotary Kedo-S Square. This could be attributed to the increased straightening of the canal by less flexible hand K and H files when compared to more flexible M-wire technology of Kedo S Square files which is in accordance with the findings of Radhika et al. [47] M-wire alloys are produced by a series of heat treatment and annealing cycles which provides them superior strength [48]. In case of having 2 files with same cross section, M-wire alloy resists fracture better than conventional alloy [49]. The benefit of the M wire technology is that these instruments exhibit greater resistance to cyclic fatigue and render the instrument more super elastic than conventional NiTi instrument [50].

The increased flexibility of the Kedo S Square file as a result of being heat treated helps in adaptation of the file to the primary canal curvature, unlike K-files that lead to more transportation and zipping [1, 10]. Heat treatment of Nickel Titanium files enables the files to attain higher torsional resistance when compared to conventional files [51]. According to Tabassum et al., the extreme ductility offered by various heat treatments may explain the superior flexibility and hence increased resistance to failure of these instruments [52].

Hence, a greater amount of dentin was removed by hand files than by rotary Kedo S Square file,which could be attributed to the non-cutting safety tip of the Kedo S Square files and to the indiscriminate and aggressive cutting action of stainless-steel files [36]. H type instrument has better cutting efficiency than K type instruments because H file has a positive rake angle where its blade cuts rather than scarps dentin unlike the K file having a negative rake angle [53].

The variable taper of the rotary Kedo-S Square file creates conservative coronal shape, which preserves dentin with deep apical shaping enabling better access for irrigation and cleaning resulting in three-dimensional obturation [26]. The principle behind varying taper is that each successive file is only engages a minimal aspect of the canal wall [54].

This is in accordance with the results of Seema et al. [30] wherein no significant difference between hand K and rotary Kedo-S files with respect to the amount of dentin removed at the middle and apical thirds; however, at the coronal third, the hand K removed significantly more dentin than the Kedo-S file in the axial cut of CBCT. Musale et al. [46] conducted a comparative assessment of dentin removal and showed that at all three levels, the K-file removed more dentin than Hero Shaper Classic with a taper of 0.04 mm, and the rotary files removed 18% less dentin in second primary molars and 17% less in first primary molars. Barasuol et al. [55] K file led to more dentin removal in the apical third than ProDesign Logic and Reciproc files as assessed using micro computed tomography.

On the contrary, other studies have reported that rotary files removed greater amount of dentin than hand files as a result of using larger tapered rotary files, which removed more dentin than the constant 2% hand files [56, 57]. Canoglu et al. [58] concluded that there were no significant differences with regards to dentin removal between the three preparation techniques (Profile 0.04 ISO), ultrasonic (K-Type/Satelec), and stainless-steel hand file K-file.

Reduced instrumentation time is highly critical in influencing the behavior of children and their co-operation in the dental chair, therefore reducing the operator’s and child’s fatigue[32]. In the current study, a significantly decreased instrumentation time was recorded with Kedo-S Square rotary file ( 2.12 min) when compared to the K-file (5.81 min) and H file (7.67 min), which is in accordance with randomized controlled study done by Lakshmanan et al. [59], where they compared Kedo-S Square rotary file to hand K and H hand files and found that Kedo-S Square rotary file had the least instrumentation time (73.4 s) when compared to the K-file (105.6 s) and highest in H file (126.8 s). Panchal et al., reported reduced instrumentation time and better obturation quality with rotary Kedo-S system than the hand K and H files groups that positively affects the cooperation of the children [28].

It must be kept in mind that the present study was conducted using only single rooted primary canines with straight roots and no apical resorption. These results were obtained in a laboratory setting and results could be different in a clinical setting. Hence, use of pediatric rotary files is recommended over hand files in order to attain successful pulpectomy technique in a simple and quick manner with proper debridement of root canals of primary teeth [27, 43].

There are some factors that enabled a reduced instrumentation time with Kedo-S-Square compared to hand K and H files. Firstly, lesser number of files in the case of Kedo-S Square (i.e., 1 single file) are used in each canal for efficient cleaning and shaping compared to the use of size No. 15 to No. 40 hand K and H files (i.e., six) for effective canal preparation. Hand files have constant taper resulting in the need for use of more files to complete the preparation [60]. Secondly, the dual cross section of the Kedo-S Square file (tear drop cross section), which is similar to H file, results in easier and complete extirpation of pulpal tissue, as opposed to the need to sequentially use of increased sizes of hand K and H-files to accomplish this task.

However, contrary to our results, Madan et al. [61] and Katge et al. [62] concluded that there was an increase in root canal instrumentation time with the use of the rotary file system in primary teeth, which may be related to the operator’s knowledge level, skill level, and experience with rotary endodontics [27].

In this study, Kedo-S Square pediatric rotary file was evaluated to understand if the newly designed exclusive rotary files for primary teeth, with a modified variable taper and shorter length, could be an alternative to the existing manual files. Further studies to evaluate patients’ acceptance of the Kedo-S Square and Kedo-S Plus rotary files are needed. Moreover, long-term clinical and radiographic success rates should be performed to reach a precise conclusion.

Conclusion

Within the experimental conditions of the present study, the following conclusions can be drawn:

  • Use of rotary Kedo-S Square resulted in good taper in maximum number of root canals unlike hand K and H files, which gave rise to maximum number of poor tapered preparations.

  • Use of Kedo-S Square files resulted in significantly greater conservation of tooth structure compared to hand K and H files at all levels except at the middle third, where there were no significant differences between the three groups.

  • Kedo-S Square file system required significantly less instrumentation time than the hand K and H file systems.

Availability of data and materials

The data that support the findings of this study are available from the corresponding author upon reasonable request.

Abbreviations

CBCT:

Cone beam computed tomography

References

  1. Ochoa-Romero T, Mendez-Gonzalez V, Flores-Reyes H, Pozos-Guillen A. Comparison between rotary and manual techniques on duration of instrumentation and obturation times in primary teeth. J Clin Pediatr Dent. 2011;35:359–64.

    Article  PubMed  Google Scholar 

  2. American, Academy, of, Pediatric, Dentistry. Guideline on pulp therapy for primary and young permanent teeth. Pediatric Dentistry. 2004;26:115–9.

  3. Coll J, Sadrian R. Predicting pulpectomy success and its relationship to exfoliation and succedaneous dentition. Pediatr Dent. 1996;18:57–63.

    PubMed  Google Scholar 

  4. Silva LA, Nelson-Filho P, Leonardo MR, Tanomaru JM. Comparison of rotary and manual instrumentation techniques on cleaning capacity and instrumentation time in deciduous molars. J Dent Child (Chic). 2004;71:45–7.

    Google Scholar 

  5. Barr ES, Kleier DJ, Barr NV. Use of nickel-titanium rotary files for root canal preparation in primary teeth. Pediatr Dent. 2000;22:77–8.

    PubMed  Google Scholar 

  6. Makarem A, Ravandeh N, Ebrahimi M. Radiographic assessment and chair time of rotary instruments in the pulpectomy of primary second molar teeth: a randomized controlled clinical trial. J Dent Res Dent Clin Dent Prospects. 2014;8:84.

    PubMed  PubMed Central  Google Scholar 

  7. Govindaraju L, Jeevanandan G, Subramanian E. Knowledge and practice of rotary instrumentation in primary teeth among Indian dentists: a questionnaire survey. Int J Oral Health Dent. 2017;9:45.

    Google Scholar 

  8. Crespo S, Cortes O, Garcia C, Perez L. Comparison between rotary and manual instrumentation in primary teeth. J Clin Pediatr Dent. 2008;32:295–8.

    Article  PubMed  Google Scholar 

  9. Finn SB. Morphology of the primary teeth. Clin Pedodontics. 1973;4:59–70.

    Google Scholar 

  10. Jeevanandan G, Ganesh S. Kedo file system for root canal preparation in primary teeth. Indian J Dent Res. 2019;30:622.

    Article  PubMed  Google Scholar 

  11. Nair M, Jeevanandan G, Vignesh R, Subramanian E. Comparative evaluation of post-operative pain after pulpectomy with k-files, kedo-s files and mtwo files in deciduous molars-a randomized clinical trial. Braz Dent Sci. 2018;21:411–7.

    Article  Google Scholar 

  12. Thakkar TK. Advances in rotary endodontics in pediatric dentistry. EC Dent Sci. 2019;18:1320–30.

    Google Scholar 

  13. Sankar P, Jeevanandan G. Microbiological evaluation of root canals after biomechanical preparation with manual and rotary file system—randomised clinical trial. Int J Dent Oral Sci. 2021;8:2841–4.

    Article  Google Scholar 

  14. Sattapan B, Nervo GJ, Palamara JE, Messer HH. Defects in rotary nickel-titanium files after clinical use. J Endod. 2000;26:161–5.

    Article  PubMed  Google Scholar 

  15. Zanza A, Seracchiani M, Di Nardo D, Reda R, Gambarini G, Testarelli L. A paradigm shift for torsional stiffness of nickel-titanium rotary instruments: a finite element analysis. J Endod. 2021;47:1149–56.

    Article  PubMed  Google Scholar 

  16. Seracchiani M, Miccoli G, Di Nardo D, Zanza A, Cantore M, Gambarini G, et al. Effect of flexural stress on torsional resistance of NiTi instruments. J Endod. 2021;47:472–6.

    Article  PubMed  Google Scholar 

  17. Parashos P, Messer HH. Rotary NiTi instrument fracture and its consequences. J Endod. 2006;32:1031–43.

    Article  PubMed  Google Scholar 

  18. Gambarini G, Cicconetti A, Di Nardo D, Miccoli G, Zanza A, Testarelli L, et al. Influence of different heat treatments on torsional and cyclic fatigue resistance of nickel–titanium rotary files: a comparative study. Appl Sci. 2020;10:5604.

    Article  Google Scholar 

  19. Baek SH, Lee CJ, Versluis A, Kim BM, Lee W, Kim HC. Comparison of torsional stiffness of nickel-titanium rotary files with different geometric characteristics. J Endod. 2011;37:1283–6.

    Article  PubMed  Google Scholar 

  20. Seracchiani M, Miccoli G, Reda R, Zanza A, Obino FV, Bhandi S, et al. A comprehensive in vitro comparison of mechanical properties of two rotary endodontic instruments. World J Dent. 2020;11:186.

    Google Scholar 

  21. Shah DY, Wadekar SI, Dadpe AM, Jadhav GR, Choudhary LJ, Kalra DD. Canal transportation and centering ability of protaper and self-adjusting file system in long oval canals: an ex-vivo cone-beam computed tomography analysis. J Conserv Dent. 2017;20:105.

    Article  PubMed  PubMed Central  Google Scholar 

  22. Srinivas A, Jeevanandan L, Govindaraju L, Subramanian EMG. Comparative evaluation of the efficacy of rotary file system (kedo-S) vs hand K-files in root canal preparation of primary teeth using cone beam computed tomography (CBCT)-an in vitro study. Braz Dent Sci. 2019;22:197–202.

    Article  Google Scholar 

  23. Katge F, Ghadge S, Poojari M, Jain K, Patil D. Comparative evaluation of cleaning efficacy of prime pedo™ and dxl-pro™ pedo rotary files with conventional h files in root canals of primary teeth: an in vitro study. J Clin Diagn Res. 2019;13:6–9.

    Google Scholar 

  24. Jeevanandan G, Thomas E. Volumetric analysis of hand, reciprocating and rotary instrumentation techniques in primary molars using spiral computed tomography: an in vitro comparative study. Eur J Dent. 2018;12:21–6.

    Article  PubMed  PubMed Central  Google Scholar 

  25. OnDemand3Dâ„¢. https://www.ondemand3d.com/pages/ondemand3d/what-is-ondemand3d.

  26. Priyadarshini P, Jeevanandan G, Govindaraju L, Subramanian E. Clinical evaluation of instrumentation time and quality of obturation using paediatric hand and rotary file systems with conventional hand K-files for pulpectomy in primary mandibular molars: a double-blinded randomized controlled trial. Eur Arch Paediatr Dent. 2020;21:693–701.

    Article  PubMed  Google Scholar 

  27. Jeevanandan G, Govindaraju L. Clinical comparison of Kedo-S paediatric rotary files vs manual instrumentation for root canal preparation in primary molars: a double blinded randomised clinical trial. Eur Arch Paediatr Dent. 2018;19:273–8.

    Article  PubMed  Google Scholar 

  28. Panchal V, Jeevanandan G, Subramanian E. Comparison of instrumentation time and obturation quality between hand K-file, H-files, and rotary Kedo-S in root canal treatment of primary teeth: a randomized controlled trial. J Indian Soc Pedod Prev Dent. 2019;37:75–9.

    Article  PubMed  Google Scholar 

  29. Babu KG, Kavyashree GH. Evaluation of the clinical efficiency of rotary and manual files for root canal instrumentation in primary teeth pulpectomies: a comparative randomized clinical trial. 2021.

  30. Seema T, Ahammed H, Parul S, Cheranjeevi J. Comparative evaluation of dentin removal and taper of root canal preparation of hand K file, ProTaper rotary file, and kedo s rotary file in primary molars using cone-beam computed tomography. Int J Clin Pediatr Dent. 2020;13:332–6.

    Article  PubMed  PubMed Central  Google Scholar 

  31. Gambill JM, Alder M, del Rio CE. Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography. J Endod. 1996;22:369–75.

    Article  PubMed  Google Scholar 

  32. Musale PK, Mujawar SA. Evaluation of the efficacy of rotary vs. hand files in root canal preparation of primary teeth in vitro using CBCT. Eur Arch Paediatr Dent. 2014;15:113–20.

    Article  PubMed  Google Scholar 

  33. Ramazani N, Mohammadi A, Amirabadi F, Ramazani M, Ehsani F. In vitro investigation of the cleaning efficacy, shaping ability, preparation time and file deformation of continuous rotary, reciprocating rotary and manual instrumentations in primary molars. J Dent Res Dent Clin Dent Prospects. 2016;10:49.

    Article  PubMed  PubMed Central  Google Scholar 

  34. Nagaratna PJ, Shashikiran ND, Subbareddy VV. In vitro comparison of NiTi rotary instruments and stainless steel hand instruments in root canal preparations of primary and permanent molar. J Indian Soc Pedod Prev Dent. 2006;24:186–91.

    Article  PubMed  Google Scholar 

  35. Azar MR, Mokhtare M. Rotary Mtwo system versus manual K-file instruments: efficacy in preparing primary and permanent molar root canals. Indian J Dent Res. 2011;22:363.

    Article  PubMed  Google Scholar 

  36. Shah HS, Patil VM, Kamath AP, Mathur AA. Comparative evaluation of instrumentation time, obturation time, and radiographic quality of obturation using two rotary systems and manual technique for primary molar pulpectomies–in vivo study. Contemp Clin Dent. 2021;12:55.

    Article  PubMed  PubMed Central  Google Scholar 

  37. Kuo CI, Wang YL, Chang HH, Huang GF, Lin CP, Li UM, et al. Application of Ni-Ti rotary files for pulpectomy in primary molars. J Dent Sci. 2006;1:10–5.

    Google Scholar 

  38. Mandel E, Adib-Yazdi M, Benhamou LM, Lachkar T, Mesgouez C, Sobel M. Rotary Ni-Ti profile systems for preparing curved canals in resin blocks: influence of operator on instrument breakage. Int Endod J. 1999;32:436–43.

    Article  PubMed  Google Scholar 

  39. Bergmans L, Van Cleynenbreugel J, Beullens M, Wevers M, Van Meerbeek B, Lambrechts P. Progressive versus constant tapered shaft design using NiTi rotary instruments. Int Endod J. 2003;36:288–95.

    Article  PubMed  Google Scholar 

  40. Hassan A, Munshi I, Tootla S. Comparison of the effect of fixed and variable taper on the volume of obturation material. S Afr Dent J. 2019;74:8–12.

    Article  Google Scholar 

  41. Yang GB, Zhou XD, Zhang H, Wu HK. Shaping ability of progressive versus constant taper instruments in simulated root canals. Int Endod J. 2006;39:791–9.

    Article  PubMed  Google Scholar 

  42. Juliet S, Jeevanandan G, Govindaraju L, Ravindran V, Subramanian EM. Comparison between three rotary files on quality of obturation and instrumentation time in primary teeth—a double blinded randomized controlled trial. J Orofac Sci. 2020;12:30–4.

    Article  Google Scholar 

  43. JeevananDan G. Kedo-S paediatric rotary files for root canal preparation in primary teeth–Case report. J Clin Diagn Res. 2017;11:ZR03-5.

    PubMed  PubMed Central  Google Scholar 

  44. Yadav A, Burman A, Dighraskar C, Surana P, Dumne SL, Prem M. Pediatric rotary files: the new era of pediatric dentistry. Int J Dent Sci Res. 2021;3:54–7.

    Google Scholar 

  45. Tepel J, Schäfer E, Hoppe H. Properties of endodontic hand instruments used in rotary motion. Part 1. Cutting efficiency. J Endod. 1995;21:418–21.

    Article  PubMed  Google Scholar 

  46. Musale PK, Jain KR, Kothare SS. Comparative assessment of dentin removal following hand and rotary instrumentation in primary molars using cone-beam computed tomography. J Indian Soc Pedod Prev Dent. 2019;37:80.

    Article  PubMed  Google Scholar 

  47. Radhika E, Reddy ER, Rani ST, Kumar LV, Manjula M, Mohan TA. Cone beam computed tomography evaluation of hand nickel-titanium K-files and rotary system in primary teeth. Pediatr Dent. 2017;39:319–23.

    PubMed  Google Scholar 

  48. Zhou H, Peng B, Zheng YF. An overview of the mechanical properties of nickel–titanium endodontic instruments. Endod Topics. 2013;29:42–54.

    Article  Google Scholar 

  49. Park SY, Cheung GS, Yum J, Hur B, Park JK, Kim HC. Dynamic torsional resistance of nickel-titanium rotary instruments. J Endod. 2010;36:1200–4.

    Article  PubMed  Google Scholar 

  50. Johnson E, Lloyd A, Kuttler S, Namerow K. Comparison between a novel nickel-titanium alloy and 508 nitinol on the cyclic fatigue life of ProFile 25/.04 rotary instruments. J Endod. 2008;34:1406–9.

    Article  PubMed  Google Scholar 

  51. Bhandi S, Seracchiani M, Donfrancesco O, Reda R, Mazzoni A, Nottola S, et al. Nickel-titanium rotary instruments: an in vitro comparison (torsional resistance of two heat-treated reciprocating files). J Contemp Dent Pract. 2021;22:361–4.

    Article  PubMed  Google Scholar 

  52. Tabassum S, Zafar K, Umer F. Nickel-titanium rotary file systems: what’s new? Eur Endod J. 2019;4:111–7.

    PubMed  PubMed Central  Google Scholar 

  53. Hargreaves KM, Cohen S, Berman LH. Instruments, materials, and devices. In: Metzger Z, Basrani B, Goodis HE, editors. Cohen’s pathways of the pulp. 10th ed. St. Louis: Elsevier; 2011. p. 230–53.

    Google Scholar 

  54. Sanghvi Z, Mistry K. Design features of rotary instruments in endodontics. J Ahmedabad Dent Coll Hosp. 2011;2:6–11.

    Google Scholar 

  55. Barasuol J, Alcalde M, Bortoluzzi E, Duarte M, Cardoso M, Bolan M. Shaping ability of hand, rotary and reciprocating files in primary teeth: a micro-CT study in vitro. Eur Arch Paediatr Dent. 2021;22:195–201.

    Article  PubMed  Google Scholar 

  56. Selvakumar H, Kavitha S, Thomas E, Anadhan V, Vijayakumar R. Computed tomographic evaluation of K3 rotary and stainless steel K file instrumentation in primary teeth. J Clin Diagn Res. 2016;10:ZC05.

    PubMed  PubMed Central  Google Scholar 

  57. Poornima P, Disha P, Nagaveni NB, Roopa KB, Bharath KP, Neena IE. ‘Volumetric analysis of hand and rotary root canal instrumentation and filling in primary teeth using Spiral Computed Tomography’—an invitro study. Int J Paediatr Dent. 2016;26:193–8.

    Article  PubMed  Google Scholar 

  58. Canoglu H, Tekcicek MU, Cehreli ZC. Comparison of conventional, rotary, and ultrasonic preparation, different final irrigation regimens, and 2 sealers in primary molar root canal therapy. Pediatr Dent. 2006;28:518–23.

    PubMed  Google Scholar 

  59. Lakshmanan L, Jeevanandan G. Evaluation of quality of obturation and instrumentation time using Kedo-S Square file, H File and K file in primary molars—a randomized controlled trial. Int J Pharm Sci Res. 2020:3507–14.

  60. da Frota MF, Bonetti Filho I, Berbert FLCV, Sponchiado EC Jr, Marques AAF, Garcia LdFR. Cleaning capacity promoted by motor-driven or manual instrumentation using ProTaper universal system: histological analysis. J Conserv Dent. 2013;16:79–82.

    Article  PubMed  PubMed Central  Google Scholar 

  61. Madan N, Rathnam A, Shigli A, Indushekar K. K-file vs ProFiles in cleaning capacity and instrumentation time in primary molar root canals: an in vitro study. J Indian Soc Pedod Prev Dent. 2011;29:2–6.

    Article  PubMed  Google Scholar 

  62. Katge F, Patil D, Poojari M, Pimpale J, Shitoot A, Rusawat B. Comparison of instrumentation time and cleaning efficacy of manual instrumentation, rotary systems and reciprocating systems in primary teeth: an in vitro study. J Indian Soc Pedod Prev Dent. 2014;32:311–6.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

The authors thank Dr. Hams, H, Abdelrahman, Assistant Lecturer of Dental Public Health, Faculty of Dentistry, Alexandria university, Egypt for help with the statistical analyses.

Funding

The authors did not receive any funding from any organizations.

Author information

Authors and Affiliations

Authors

Contributions

AM.A and AA.S conceived the ideas; R.H.M. collected the data; and A.M.A., A.A.S. and R.H.M. led the writing and revision of the manuscript.

Corresponding author

Correspondence to Rasha H. Mohamed.

Ethics declarations

Ethics approval

The Scientific Research Ethics Committee of Alexandria Dental University approved this study.

Consent for publication

Not applicable.

Competing interests

The authors declare no conflict of interest with respect to the authorship and/or publication of this article.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Mohamed, R.H., Abdelrahman, A.M. & Sharaf, A.A. Evaluation of rotary file system (Kedo-S-Square) in root canal preparation of primary anterior teeth using cone beam computed tomography (CBCT)-in vitro study. BMC Oral Health 22, 13 (2022). https://doi.org/10.1186/s12903-021-02021-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12903-021-02021-0

Keywords