Establishment, FEM analysis and experimental validation of tooth movement prediction model of orthodontic archwire T-loop

Abstract

Background

The T-loop has been used clinically to close gap between teeth. And it is a typical orthodontic archwire bending method. However, the design of the T-loop parameters for different patients is based on the clinical experience of the dentists. The variation in dentists' clinical experience is the main reason for inadequate orthodontic treatment, even high incidence of postoperative complications.

Methods

Firstly, the tooth movement prediction model is established based on the analysis of the T-loop structure and the waxy model dynamic resistance. As well as the reverse reconstruction of the complete maxillary 3D model based on the patient CBCT images, the oral biomechanical FEM analysis is completed. A maxillary waxy dental model is manufactured to realize the water-bath measurement experiment in vitro mimicking the oral bio-environment. Thus, the calculated, simulation and experimental data are obtained, as well as obtaining a cloud of total deformation from the simulation analysis.

Results

The growth trend of the 11 sets of simulation data is the same as that of the experimental data. And all of them show that the tooth displacement is positively correlated with the cross-sectional size of the archwire, and the clearance distance. As well as the higher Young's modulus of the archwire material, the greater the tooth displacement. And the effect of archwire parameters on tooth displacement derived from simulation and experimental data is consistent with the prediction model. The experimental and calculated data are also compared and analyzed, and the two kinds of data are basically consistent in terms of growth trends and fluctuations, with deviation rates ranging from 2.17  to  10.00%.

Conclusions

This study shows that the accuracy and reliability of the tooth movement prediction model can be verified through the comparative analysis and deviation calculation of the obtained calculated, simulation and experimental data, which can assist dentists to safely and efficiently perform orthodontic treatment on patients. And the FEM analysis can achieve predictability of orthodontic treatment results.

Peer Review reports

Background

In recent years, oral malocclusion has shown a high prevalence and is one of the three major oral diseases [1]. It affects oral function, craniofacial development, appearance and interpersonal relationships, and even causes psychological disorders in minors [2, 3, 4]. Orthodontic techniques can effectively treat malocclusion. During orthodontic treatment, due to the phenomenon of orthodontic crowding, some teeth are selectively extracted and a corresponding extraction gap is formed. For this reason, the closure of the extraction gap is a very important aspect [5], which is directly related to the smooth implementation of the entire orthodontic plan [6, 7, 8].

T-loop is widely used to close gap between teeth due to the structural characteristics that can generate horizontal, vertical and torsional force [9, 10, 11, 12, 13]. During the process of closing gap, the teeth are subjected to both the orthodontic force generated by the T-loop and the biological resistance of the periodontal tissues [14, 15, 16]. In turn, the orthodontic force generated by the archwire are inextricably linked to the clearance distance, cross-sectional size and material properties of the T-loop [17, 18].

In traditional orthodontic diagnosis, depending on the treatment stage and specific orthodontic purpose, dentists select archwire parameters empirically [19, 20, 21, 22]. This leads to unpredictable tooth movement, and can easily cause irreparable damage to the patients and reduce treatment efficiency [13]. During the treatment, if the tooth movement is too small, the orthodontic effect is not obvious, and if the tooth movement is too large, it can increase the patient's dental pain, leading to periodontal tissue damage, tooth loosening, and even serious root and alveolar bone resorption problems [23, 24, 25]. Therefore, dentists will find the optimal position by repeatedly adjusting the parameters of the orthodontic archwire. However, repeated adjustments can reduce the mechanical properties of the orthodontic archwire. And it also increases the clinical treatment time and causes inconvenience to both the dentist and the patient. Therefore, by revealing the relationship between archwire parameters, orthodontic force and tooth movement, it enables the dentist to develop an individualized orthodontic treatment plan by taking into account the patient's malocclusion, the mechanical behavior of archwire and the tooth movement pattern. This further improves the efficiency and safety of fixed orthodontic treatment and reduces the patient's pain.

In this paper, based on the dynamic resistance model of the waxy model and the dynamic orthodontic force model of the T-loop, a tooth movement prediction model is established to realize the tooth movement prediction analysis. The T-loop parameters and tooth movement distance are quantified. And FEM analysis and experimental validation are both conducted. Experimental data are collected using the designed tooth movement measurement method. And the accuracy of the tooth movement prediction model is demonstrated by data comparison and deviation analysis.

Therefore, the tooth movement prediction model established in this paper can assist dentists in selecting the appropriate T-loop parameters for the movement distance and angle of the tooth. Thus, it provides a theoretical basis for the development of individualized orthodontic treatment plans for patients. At the same time, it reduces the clinical treatment time of patients and dentists, improves orthodontic efficiency, as well as achieves predictability of orthodontic treatment effect.

Methods

Dynamic resistance analysis of waxy model

In order to restore the relative tooth movement under realistic conditions, a non-rigid waxy model is chosen to simulate the biological properties of the periodontal environment. Non-rigid waxy models are widely used in dental clinical experiments and training because the viscous fluid properties vary with temperature, such as the Typodon orthodontic training model [26, 27]. As well as Liu et al. experimentally verified the feasibility of the waxy model for simulating tooth movement at a certain temperature [28]. Meanwhile, according to the theory of viscous fluid dynamics, during orthodontic treatment, the impedance force of tooth in waxy model is composed of resistance and inertia force [29]. Through experimental verification, the optimal water-bath temperature for tooth movement in the waxy model is determined to be 75 °C [30, 31]. At the same time, an expression for the variation of the waxy dental density with time is established. According to the expression, the resistance equation and the inertia force equation, the dynamic resistance model of the waxy dental model in the process of simulated tooth movement is established [32, 33], as shown in Fig. 1.

Fig. 1
figure 1

Waxy dynamic resistance model during tooth movement

Modeling of dynamic orthodontic force in T-loop

During orthodontic treatment, the tooth movement is influenced by a combination of the periodontal tissue's biological resistance and the orthodontic force generated by the archwire. Besides, orthodontic force changes dynamically as treatment progresses [32]. Therefore, before establishing a tooth movement prediction model, a dynamic orthodontic force model needs to be established.

Analysis of T-loop working as follows: the dentist pulls the horizontal arm of T-loop to create a clearance, causes elastic deformation of the vertical arm and the arc portion, and then fixes the horizontal arm on the bracket. The tooth is pulled to a predetermined position using the restoring force of the T-loop itself, thus completing the closure of the gap between teeth [19, 20]. At the same time, T-loop with symmetrical structure is used, that is, the Alpha/Beta structure on both sides of T-loop is equal, so that the orthodontic force released by the horizontal arm can be equal and opposite [34]. Therefore, only one side of T-loop needs to be analyzed. The T-loop deformation analysis is shown in Fig. 2.

Fig. 2
figure 2

T-loop deformation and vertical arm force analysis

The orthodontic force generated by the T-loop is composed of the vertical arm and the arc portion of the deformation superimposed. So the vertical arm and the arc portion are modeled mechanically separately. And then the total orthodontic force of the T-loop is calculated by superposition. Firstly, the vertical arm is subjected to force analysis and mechanical modeling. As shown in Fig. 2, the bending radius of the arc portion is R, the total height is h, the length of the vertical arm is y. By pulling the horizontal arm of the T-loop creates a clearance distance b. And the component of the force applied to the horizontal arm that deforms the vertical arm is p.

The approximate differential equation for the vertical arm deflection curve is as follows:

$$\frac{{{\text{d}}^{2} v}}{{{\text{d}}x^{2} }} = \frac{M(x)}{{EI_{z} }}$$
(1)

where E is the elastic modulus of material, M(x) is the bending moment of the vertical arm at x distance. Iz is the rotational inertia of the archwire z-axis. The rotational inertia of a round archwire is Iz = πD4/64, and D is the diameter of the round archwire. For a rectangular archwire Iz = c1c23/12. The c1 is length of the side perpendicular to the z-axis on the rectangular archwire cross-section. The rotation angle equation θ(x) and the deflection equation ν(x) for the vertical arm can be obtained by integrating Eq. (1) once and twice, respectively.

$$\left\{ \begin{gathered} \theta (x) = \frac{{{\text{d}}v(x)}}{{{\text{d}}x}} = \int {\frac{M(x)}{{EI_{{\text{z}}} }}{\text{d}}x + C_{0} } \hfill \\ v(x) = \int {\int {\frac{M(x)}{{EI_{{\text{z}}} }}{\text{d}}x{\text{d}}x + C_{0} x + D_{0} } } \hfill \\ \end{gathered} \right.$$
(2)

where C0 and D0 are integration constants that can be determined by the boundary conditions at special points. The expression for the bending moment of the vertical arm is:

$$M(x) = - P(y - x)$$
(3)

Substituting Eqs. (1) and (3) into Eq. (2) for integration, obtaining:

$$\left\{ \begin{gathered} \theta (x) = \int {\frac{P}{{EI_{z} }}(x - y){\text{d}}x = } \frac{P}{{EI_{z} }}(\frac{{x^{2} }}{2} + yx) + C_{0} \hfill \\ v(x) = \int {\int {\frac{P}{{EI_{z} }}(x - y){\text{d}}x{\text{d}}x = } \frac{P}{{EI_{z} }}(\frac{{x^{3} }}{6} + \frac{{yx^{2} }}{2}) + C_{0} x + D_{0} } \hfill \\ \end{gathered} \right.$$
(4)

Using the special points with known deflection and rotation angle, the integration constants in Eq. (4) can be determined. Since the longitudinal symmetry plane exists at the intersection of horizontal arm of the arc portion and vertical arm, and the symmetry plane is subject to external force, the axis of the deformed curved beam is still located within the longitudinal symmetry plane. The intersection point deformation belongs to the plane bending deformation of the curved beam. Therefore, the arc at the intersection can be equated to a curved beam with radius, curvature and section diameter. To take the radius micro-element dα cross section, as shown in Fig. 3.

Fig. 3
figure 3

Deformation analysis of nodes and horizontal arm of the arc portion

After deformation, the differential equation of the deflection curve at the intersection of horizontal arm of the arc portion and vertical arm is as follows:

$$\frac{{{\text{d}}^{2} u}}{{{\text{d}}s^{2} }} + \frac{u}{{R^{2} }} = - \frac{{M_{0} }}{{EI_{\omega } }}$$
(5)

where u is the displacement of the curved beam in the x-direction intersection cross section. The bending moment condition at the intersection is known to be \(M_{0} = \left. M \right|_{x = 0} = - Py\). \(I_{\omega }\) is the rotational inertia of the curved beam's cross section on the ω axis. The vertical arm is consistent with the bending form of the curved beam at the intersection, so \(I_{\omega } = I_{z}\). Also it is defined the arc length equation ds = Rdα, and obtained the differential equation of the deflection curve at the intersection point after substitution, as shown in Eq. (6):

$$\frac{{{\text{d}}^{2} u}}{{{\text{d}}\alpha^{2} }} + u = - \frac{{M_{0} R^{2} }}{{EI_{\omega } }}$$
(6)

The non-associative differential equation with constant coefficients for the deflection curve after deformation of the curved beam at the intersection point is:

$$u(\alpha ) = A_{0} \cos \alpha + B_{0} \sin \alpha - \frac{{M_{0} R^{2} }}{{EI_{\omega } }}$$
(7)

The boundary condition at the intersection is \(u{|}_{{\alpha { = }\pi /2}} = 0\), \(\left. {\frac{{{\text{d}}u}}{{{\text{d}}\alpha }}} \right|_{\alpha = \pi /2} = 0\). Therefore, it can be determined that A0 = 0, \(B_{0} { = }\frac{{M_{0} R^{2} }}{{EI_{\omega } }}\), and bring them into Eq. (7) to obtain Eq. (8):

$$u(\alpha ) = \frac{{M_{0} R^{2} }}{{EI_{\omega } }}\sin \alpha - \frac{{M_{0} R^{2} }}{{EI_{\omega } }}$$
(8)

Also, the corner equation of the curved beam can be obtained as:

$$\beta (\alpha ) = \frac{{{\text{d}}u}}{{{\text{d}}s}} = \frac{{M_{0} R\cos \alpha }}{{EI_{\omega } }}$$
(9)

By introducing of boundary conditions \(\left. v \right|_{x = 0} = \left. u \right|_{\alpha = 0} = - \frac{{M_{0} R^{2} }}{{EI_{\omega } }}\), \(\left. \theta \right|_{x = 0} = \left. \beta \right|_{\alpha = 0} = \frac{{M_{0} R^{{}} }}{{EI_{\omega } }}\), to obtain \(C_{0} = \frac{{M_{0} R^{{}} }}{{EI_{\omega } }}\), \(D_{0} = - \frac{{M_{0} R^{2} }}{{EI_{\omega } }}\).

Bringing \(C_{0}\) and \(D_{0}\) into Eqs. (4) and (10), obtaining:

$$\left\{ \begin{gathered} \theta (x) = \frac{P}{{EI_{z} }}(\frac{{x^{2} }}{2} + yx) + \frac{{M_{0} R}}{{EI_{w} }} \hfill \\ v(x) = \frac{P}{{EI_{z} }}(\frac{{x^{3} }}{6} + \frac{{yx^{2} }}{2}) + \frac{{M_{0} R}}{{EI_{w} }}x + \frac{{M_{0} R}}{{EI_{w} }} \hfill \\ \end{gathered} \right.$$
(10)

According to the established deflection differential equation, the corresponding boundary conditions are replaced: the maximum deflection value m, and the maximum rotation angle at x = y. The external force that deforms the vertical arm is then obtained as:

$$p = - \frac{{3[mEI_{z} + M_{0} R(y - R)]}}{{y^{3} }}$$
(11)

Further according to the principle of action and reaction force, the force P that deforms the vertical arm is equal to the counter force of the orthodontic force F1 applied to the tooth during the orthodontic procedure. Thus, it can be obtained that:

$$F_{1} = - p = \frac{{3[mEI_{z} + M_{0} R(y - R)]}}{{y^{3} }}$$
(12)

As mentioned earlier, the arc portion and the deformation of the vertical arm together constitute the orthodontic force generated by the T-loop during correction. After the analysis of the vertical arm, a mechanical modeling.

analysis of the arc portion is performed. Similar to the analysis of the vertical arm, the horizontal arm of the arc portion as the main deformation part, need to establish the corresponding deformation equation, as shown in Fig. 3.

During the deformation of the T-loop, the position of the connection between the horizontal arm of the arc portion and the vertical arm is constantly changing. It is not easy to measure the distance that the horizontal arm of the arc portion moves. Therefore, it is necessary to simplify the movement of the intersection symmetry center during the T-loop deformation. The symmetry center of the intersection before deformation is overlapped, and the difference between the theoretical length and the initial length of the vertical arm after deformation is calculated. This difference is the bending deformation s of the horizontal arm of the arc portion, which can be obtained from the following equation:

$$s = \sqrt {m^{2} + y^{2} } - y$$
(13)

where y is the length of the vertical arm in the natural state and also the bending deflection of the vertical arm. Similar to Eq. (1), the deflection curve differential equation for the horizontal arm of the arc portion is:

$$\frac{{{\text{d}}^{2} v}}{{{\text{d}}l^{2} }}{ = }\frac{M(l)}{{EI_{z} }}$$
(14)

The corner Eq. (15) and the deflection Eq. (16) for the horizontal arm of the arc portion can be determined by integrating Eq. (14) once and twice, respectively:

$$\theta (l) = \frac{{{\text{d}}v(l)}}{{{\text{d}}l}} = \int {\frac{M(l)}{{EI_{{\text{z}}} }}{\text{d}}l + C_{1} }$$
(15)
$$v(l) = \frac{{{\text{d}}^{2} v(l)}}{{{\text{d}}l^{2} }}{ = }\int {\int {\frac{M(l)}{{EI_{{\text{z}}} }}{\text{d}}l{\text{d}}l + C_{1} } } l + D_{1}$$
(16)

where C1 and D1 are integration constants, and the bending moment expression for the horizontal arm of the arc portion is:

$$M(l) = - G(w - R - l)$$
(17)

where G is the component that deforms the horizontal arm of the arc portion, w is the total length of the horizontal arm of the arc section, and R is the bending radius of the arc portion. Substituting Eqs. (14) and (17) into Eqs. (15) and (16) for integration, the following equation is obtained:

$$\theta (l) = \int {\frac{G}{{EI_{z} }}(l + R - w)dl = } \frac{G}{{EI_{z} }}(\frac{{l^{2} }}{2} + Rl - wl) + C_{1}$$
(18)
$$\begin{gathered} v(l) = \int {\int {\frac{G}{{EI_{z} }}(l + R - w){\text{d}}l{\text{d}}l} } \hfill \\ { = }\frac{G}{{EI_{z} }}(\frac{{l^{3} }}{6} + \frac{{Rl^{2} - wl^{2} }}{2}) + C_{1} l + D_{1} \hfill \\ \end{gathered}$$
(19)

The lateral arc on one side can be equated to a curved beam of radian π/4, and the radian dβ is taken to be infinitesimal. This is the same process as solving for the vertical arm boundary condition, so the boundary condition can be given as:

$$u(\beta ) = A_{1} \cos \beta + B_{1} \sin \beta - \frac{{M_{0} R^{2} }}{{EI_{\omega } }}$$
(20)

The boundary conditions of the arc portion are \(\left. u \right|_{\beta = \pi } = 0\), \(\left. {\frac{{{\text{d}}u}}{{{\text{d}}\beta }}} \right|_{\beta = \pi } = 0\), and the general solutions obtained are \(A_{1} = \frac{{M_{0} R^{2} }}{{EI_{\omega } }}\), \(B_{1} = 0\). Then the deflection equation of the arc portion is:

$$u(\beta ) = \frac{{M_{0} R^{2} }}{{EI_{\omega } }}\cos \beta - \frac{{M_{0} R^{2} }}{{EI_{\omega } }}$$
(21)

The corner equation of the arc portion is:

$$\varepsilon (\beta ) = \frac{{{\text{d}}u}}{{{\text{d}}s}} = - \frac{{M_{0} R\sin \beta }}{{EI_{\omega } }}$$
(22)

Because the boundary conditions are \(\left. v \right|_{{l{ = 0}}} = \left. u \right|_{\beta = 0} = 0\) and \(\left. \theta \right|_{l = 0} = \left. \varepsilon \right|_{\beta = 0} = 0\), it is able to obtain C1 = 0 and D1 = 0. Substituting C1 = 0 and D1 = 0 into Eqs. (18) and (19) obtains Eqs. (23) and (24):

$$\theta (l) = \frac{G}{{EI_{z} }}(\frac{{l^{2} }}{2} + Rl - wl)$$
(23)
$$v(l) = \frac{G}{{EI_{z} }}(\frac{{l^{3} }}{6} + \frac{{Rl^{2} - wl^{2} }}{2})$$
(24)

The corresponding boundary conditions are substituted as follows: when l = w-R, the horizontal arm of the arc portion reaches the maximum deflection at its end, which is v = s, approximated by the same Eq. (13). Further can get the bending force of the horizontal arm of the arc portion, as follows:

$$G = - \frac{{3sE_{z} }}{{(R - w)^{3} }}$$
(25)

From further mechanical analysis, it is obtained that the component force along the horizontal arm should be equal to the orthodontic force F2 released by the arc portion. The following equation is obtained:

$$F_{2} = - G \times \sin \theta = \frac{{3mEI_{z} (\sqrt {y^{2} + m^{2} } - y)}}{{(w - R)^{3} \sqrt {y^{2} + m^{2} } }}$$
(26)

From the mechanical analysis, the restoring force from the deformation of the vertical arm and the arc portion together constitute the orthodontic force F0 released by the horizontal arm. That is, the following equation:

$$\begin{gathered} F_{0} = F_{1} { + }F_{2} \hfill \\ { = }\frac{{3[mEI_{Z} + M_{0} R(y - R)]}}{{(y - R)^{3} }} + \frac{{3mEI_{z} (\sqrt {y^{2} + m^{2} } - y)}}{{(w - R)^{3} \sqrt {y^{2} + m^{2} } }} \hfill \\ \end{gathered}$$
(27)

Establishment of tooth movement prediction model

After the previous calculations, the dynamic resistance model for the tooth movement simulated in the waxy model can be expressed by Eq. (28):

$$f = f_{D} + f_{L} = \frac{1}{2}C_{D} \rho (t)Av_{0}^{2} + C_{M} M_{0} \frac{dv}{{dt}}$$
(28)

where f is the dynamic resistance to tooth movement in the waxy model. Bringing in the orthodontic force F0 released by the T-loop, it is obtained that:

$$\begin{gathered} F{ = }F_{0} - f{ = }F_{0} - f_{D} - f_{L} \hfill \\ { = }F_{0} - \frac{1}{2}C_{D} \rho (t)Av_{0}^{2} - C_{M} M_{0} \frac{{{\text{d}}v}}{{{\text{d}}t}} \hfill \\ \end{gathered}$$
(29)

In physics, the relationship between the displacement r and the velocity vector v, Eq. (30), can be determined by integrating:

$$\left\{ \begin{gathered} r = \, r_{0} + \int {vdt} \hfill \\ v = \, v_{0} + \int {a{}_{0}dt} \hfill \\ \end{gathered} \right.$$
(30)

In Newton's Second Law, the relationship between the acceleration a0, the mass m0 and the force F can be expressed by Eq. (32):

$$F{ = }m_{0} a_{0}$$
(31)

The acceleration a0 of the tooth moving in the waxy model, subject to orthodontic force F0, inertial force fL and resistance fD, can be expressed by Eq. (32):

$$a_{0} = \frac{{F_{0} - \frac{1}{2}C_{D} \rho (t)Av_{0}^{2} - C_{M} M_{0} \frac{dv}{{dt}}}}{{m_{0} }}$$
(32)

By substituting Eq. (33) into (31), the tooth movement prediction model can be obtained. The following equation can be obtained:

$$S_{m} = v_{0} t_{1} + \frac{{F_{0} - \frac{1}{2}C_{D} \rho (t)Av_{0}^{2} - C_{M} M_{0} \frac{dv}{{dt}}}}{{2m_{0} }}t_{1}^{2}$$
(33)

where Sm is the amount of tooth movement under the action of the T-loop in the waxy model, m0 is the mass of the tooth, and t1 is the time of tooth movement.

Tooth movement FEM analysis

In this study, a 3D model of the complete maxillary bone, dental row and periodontal ligament is reconstructed in reverse by using CBCT images (EWOO-VATECH Co., Ltd., Korea, scan thickness 0.5 mm, 301 scanned images) based on the patient's skull. And according to the clinical orthodontic treatment process, a 3D model with brackets and T-loop is installed on the reconstructed dental. At last, the orthodontic biomechanical FEM analysis is performed for the complete assembly model. The flowchart of the reverse 3D reconstruction model is shown in Fig. 4. And the simulation cloud is shown in Fig. 5. In the simulation process, the archwire is adopted of stainless steel archwire and Australian archwire, which are commonly used in clinical orthodontics. In addition, the material properties of the brackets and maxillary components are shown in Table 1 [34, 35, 36].

Fig. 4
figure 4

Flowchart of reverse 3D reconstruction of maxilla and dentition. (a) CBCT images; (b) one and three dimensional point cloud images in Mimics; (c) point cloud model surfacing and model optimization in Geomagic; (d) assembly of reconstructed models of the maxillary parts in SolidWorks

Fig. 5
figure 5

T-loop based maxillary biomechanical FEM analysis of the deformation cloud

Table 1 Properties of the materials used in the FEM analysis

The simulation parameters shown in Fig. 5 are: (1) The archwire is a 0.014-inch round Australian archwire. (2) The material of the bracket is stainless steel. (3) The top of the maxilla is fixedly constrained. (4) The contact between the archwire and the brackets, between the brackets and the teeth is bound. (5) The archwire is meshed with 0.1 mm size and the others are meshed with 1.0 mm, so that the deformation of the archwire can be calculated more accurately. And the total number of nodes and cells of the mesh is 235,827 and 138,031 respectively. In addition, the displacement load is defined as follows: set 10 analysis steps so that the clearance distance grows linearly with 0.1 of the step length, and take the clearance distance as 0.3–1.2 mm for FEM analysis. And the maximum displacement of NO. 13 tooth is 1.4575 mm at the cusp and the minimum displacement is 0.2512 mm at the root, which meets the clinical orthodontic requirements [37, 38].

Tooth movement experimental measurement method

In this study, the waxy model is used to simulate the periodontal tissue structure. Firstly, alginate is used as the impression material, and the separated teeth are placed into the alginate negative mold, then the molten waxy base is poured, left to cool and removed. Thus, the preparation of waxy dental model for experimental use is completed. Due to the viscoelastic properties at the corresponding temperature, the waxy model under the action of external force will produce a corresponding elastic deformation [28]. Finally, the teeth on the waxy model will complete the simulation of the orthodontic process with the change of time. The experimental system composition and the waxy dental model are shown in Fig. 6. Also detailed waxy model preparation process and modeling methods have been described in the study of Huang et al. [32].

Fig. 6
figure 6

Installed waxy dental model with T-loop and tooth movement experiment system

The position of each maxillary teeth is marked using the FDI (Fédération Dentaire Internationale) marking method, and maxillary teeth No. 13 and No. 15 are selected as the teeth for the experimental study. Before clinical orthodontic treatment, a total of four teeth in the maxilla and mandible are usually extracted to allow enough space for remaining teeth to move. In the experiment, tooth No.14 is extracted and the two horizontal arms of the T-loop are ligated into the brackets of teeth No. 13 and No. 15. The highest points of the marginal crests of the two teeth are marked, as shown in Fig. 6. The distance between the two marker points is measured before the water-bath experiment, and then the waxy model is immersed in a constant temperature water-bath at 75 °C for 2 min. After taking out, the distance between the two marker points is measured again with a vernier caliper [32]. The difference of the distance between the two marker points before and after the water-bath is sought as the experimental value of the tooth movement distance under the action of T-loop.

Results

In clinical treatment, the magnitude of orthodontic force is changed by adjusting the characteristic parameters of the T-loop. And the magnitude of orthodontic force has an important influence on the tooth movement, the periodontium disease, tooth root resorption, and the alveolar bone reconstruction [39]. Therefore, in this study, the accuracy and reliability of the tooth movement prediction model is verified by comparing and analyzing the calculated, simulation and experimental data. In the FEM analysis, 11 kinds of T-loop 3D models with different parameters are established based on clinical orthodontic treatment. The loading process of the FEM analysis is the same as described before, with the aim of investigating the effects of different clearance distances, cross-sectional and materials on tooth movement. To be easily represented, the orthodontic archwires are codenamed as follows: I-S1616, II-S1622, III-S1625, IV-S0014, V-S0016, VI-S0018, VII-S0020, VIII-A0014, IX-A0016, X-A0018, XI-A0020. Where S is stainless steel archwire, A is Australian archwire, 1616 indicates 0.016 × 0.016 inch rectangular archwire, and 0014 indicates 0.014 inch round archwire. Similarly, the 11 kinds of T-loop bending parameters used in the experimental are the same as those of the 3D model, and 10 measurement points are set at 0.1 mm intervals to collect data during the loading measurement stage of the experiment. The calculated, simulation and experimental data are shown in Table 2. As well, the total strain clouds for the biomechanical FEM analysis of tooth movement under the action of 11 kinds of T-loop are shown in Fig. 7.

Table 2 Summary of calculated, simulation and experimental data
Fig. 7
figure 7

Total strain clouds for biomechanical FEM analysis of tooth movement based on T-loop

In this paper, the simulation data and experimental data are compared and analyzed, so that the accuracy and reliability of simulation analysis and experimental measurement can be verified with each other.

Figure 8 shows the effect of rectangular archwire with different cross-sectional widths (Codenamed as I, II, and III) on the variation of tooth displacement with T-loop clearance distance. Both simulation and experimental results shows that the tooth displacement is positively correlated with the cross-sectional width for the same clearance distance. Similarly, the tooth displacement is positively correlated with the clearance distance for the same cross-sectional width. In addition, the effect of cross-sectional width on tooth displacement increases as the clearance distance increases.

Fig. 8
figure 8

Tooth displacement produced by rectangular stainless steel archwire with different cross-sectional widths and clearance distances

Comparing different round cross-sectional diameter (Codenamed as IV, V, VI, and VII), the effect of tooth displacement with the variation of T-loop clearance distance is shown in Fig. 9. Both simulation and experimental results show that the tooth displacement is positively correlated with the cross-sectional diameter of the T-loop for the same clearance distance, which is similar to the conclusion for rectangular archwire. From the simulation and experimental results, although the cross-sectional diameter of the archwire affects the tooth displacement, its effect is weaker than that of the clearance distance of the T-loop.

Fig. 9
figure 9

Tooth displacement produced by round stainless steel archwire with different cross-sectional diameters and clearance distances

In clinical orthodontic treatment, stainless steel archwire and Australian archwire are mainly used. Therefore, two sets of results based on material are divided. The data of four identical archwire types in the two sets are compared to investigate the effect of different archwire materials on tooth displacement [5, 32]. The stainless steel archwires are codenamed as IV, V, VI, and VII, and the Australian archwires are codenamed as VIII, IX, X, and XI. As shown in Fig. 10, both the simulation and experimental data show that the effect of tooth displacement with the same cross-sectional dimensions is more pronounced with increasing clearance distance using stainless steel archwire than Australian archwire. In addition, this conclusion became more evident as the diameter of the archwire increased.

Fig. 10
figure 10

Comparison of tooth displacement with different archwire materials

While mutually verifying the accuracy and reliability of the simulation analysis and experimental measurements, this paper analyses the calculated and experimental data, and performs deviation calculations to verify the accuracy and validity of the tooth movement prediction model. The calculated data is shown in Table 2. And in Figs. 11, 12, 13, the experimental and calculated data, and deviation rates are shown by solid, dashed and dotted lines, respectively.

Fig. 11
figure 11

Comparison of experimental and calculated data with different cross-sectional widths, and deviation rate

Fig. 12
figure 12

Comparison of experimental and calculated data of stainless steel archwire at different clearance distances, and deviation rate

Fig. 13
figure 13

Comparison of experimental and calculated data of Australian archwire at different clearance distances, and deviation rate

A comparison of experimental and calculated data of tooth displacement versus clearance distance for rectangular stainless steel archwire of different cross-sectional widths (Codenamed as I, II and III) is shown in Fig. 11. The obtained calculated and experimental data have the same trend and the deviation varies from 2.17  to  8.86%. When other conditions are the same, the trend of the curves shows that the calculated data of tooth displacement are positively correlated with the cross-sectional width, and the effect of the cross-sectional width on tooth displacement increases with the increase of the clearance distance.

For the round archwire, the comparison of experimental and calculated data of tooth displacement for different cross-sectional sizes of stainless steel archwire (Codenmed as IV, V, VI, VII) and Australian archwire (codenamed as VIII, IX, X, XI) at different clearance distances, and deviation rates are shown in Figs. 12 and 13. The trends of the calculated and experimental data are consistent in different archwire materials. The deviation rate of calculated and experimental data for stainless steel archwire ranges from 2.36  to  10.00%, while the deviation rate of Australian archwire ranges from 2.47  to  9.38%. For the two kinds of orthodontic archwire with different materials, the larger the cross-sectional size of the archwire, the greater the tooth displacement effect produces when the clearance distance is the same. When the cross-sectional size are all the same, the tooth displacement effect produced by the round orthodontic archwire is positively correlated with the clearance distance.

Discussion

In order to reveal the tooth movement characteristics under different force during clinical orthodontic procedure, researchers have studied it through experimental measurements, FEM analysis and theoretical derivation. For example, researchers have established FEMs of tooth movement under different orthodontic force [40, 41, 42, 43]. During the simulation, the magnitude and direction of the orthodontic force is artificially set without reference, which is not consistent with the clinical reality. In addition, periodontal tissues cannot be effectively differentiated by materials, so corresponding experimental validation should be performed. However, experimental materials are mostly rigid models, such as plaster models or metal models [44], which lack biological properties. In addition, the orthodontic process is a dynamic one, and the orthodontic force will become weaker with the reduction of archwire deformation. Therefore, the real orthodontic effect cannot be effectively reproduced and the prediction function is not yet perfect. In contrast, the T-loop is a common orthodontic arch for clinical treatment of such oral malocclusion as closing the gap between teeth. Although the relationship between archwire shape and orthodontic force for T-loop has been studied to some extent [45, 46, 47, 48], but the archwire bending parameter and orthodontic force relationship, orthodontic force and tooth movement relationship have not been established. Therefore, the current studies still cannot assist dentists to effectively develop individualized T-loop parameter designs for different patients, as well as to accurately predict orthodontic treatment effect.

Thus, this paper firstly establishes a tooth movement prediction model based on the T-loop analysis and the waxy model dynamic resistance. Subsequently, to verify the accuracy of the prediction model, a reverse reconstruction model of the maxillary and dentition based on the patient's CBCT images is used to achieve a biomechanical FEM analysis of the tooth movement. Finally, a waxy dental model is established, and a water-bath measurement experiment mimicking the biological environment of the oral cavity is realized. Simulation analysis and experimental measurements are compared to verify each other's accuracy and reliability. And as shown in Figs. 8 and 9, the conclusion about the influence of different archwire parameters on tooth movement derived from the simulation analysis and experimental measurements is consistent with the established tooth movement prediction model. This further illustrates the accuracy of the simulation analysis and experimental measurements.

Afterwards, the prediction model and experimental measurements are compared and analyzed, and the deviation is calculated, and the total deviation range between the calculated and experimental data is obtained: 2.17  ~ 10.00%, which is within the acceptable range and is approved by the dentists of Peking University School of Dentistry. In addition, it can be determined from the trends shown in Figs. 11, 12 and 13 that the movement of the target tooth is positively correlated with both square and round archwire in terms of clearance distance and cross-sectional parameters. And the tooth displacement in the stainless steel archwire move faster than those in the Australian archwire as the clearance distance increases. The tooth displacement of the Australian archwire is milder for the same T-loop parameters. These trends and correlations are corrected with the existing academic studies in this field.

Conclusions

In this paper, based on the analysis of the T-loop structure and the waxy model dynamic resistance, a tooth movement prediction model is established. The relationship between T-loop parameters, orthodontic force and tooth movement are revealed and quantified. The validity and reliability of the simulation analysis and experimental measurements, as well as the accuracy of the tooth movement prediction model, are verified by comparing and analyzing the simulation analysis and experimental measurements with each other, as well as calculating and analyzing the deviation of the experimental and calculated data.

Therefore, it can be affirmed that the established tooth movement prediction model has a high degree of confidence and can assist dentists in selecting the appropriate archwire parameters when bending T-loop to obtain the desired tooth movement distance. At the same time, the tooth movement prediction model provides dentists with an effective theoretical guide to avoid inefficient bending of archwire and improve the treatment effect of malocclusion. Moreover, the process and results of the FEM analysis enable predictive orthodontic treatment effects, thus laying the foundation for the realization of digital orthodontic treatment.

In future work, other detailed factors that may affect tooth movement during orthodontic treatment will be further explored. Such as the relative static friction and relative sliding friction between the orthodontic archwire and brackets, and how to choose the right archwire parameters to achieve the best orthodontic effects and speed up the treatment process.

Availability of data and materials

All relevant data are within the present paper; however, the ethics committee strictly forbids sharing the CBCT files of patients and control subjects that they contain some identifying information, according to its regulations on the data access. Therefore, CBCT data of the samples will not be shared. Also the reverse reconstructed 3D models in this paper are belong to the authors and are therefore available only upon request, after approval by all the authors. And if required, please contact the corresponding author of this paper (Correspondence: jiangjingang@hrbust.edu.cn).

Abbreviations

FEM:

Finite element method

3D:

Three dimensional

FDI:

Fédération dentaire internationale

References

  1. Jiang JG, Huang ZY, Qian W, et al. Registration technology of augmented reality in oral medicine: a review. IEEE Access. 2019;7:53566–84.

    Article  Google Scholar 

  2. He L, Zhang JT. Progress in research on opening and closing malformation. Electr J Gen Stomatol. 2019;6(27):11–2.

    Google Scholar 

  3. Yao H, Zhao EY, Qin JY. Research progress on the prevalence of malocclusion. China Primary Health Care. 2003;17(10):74.

    Google Scholar 

  4. Zeng J, Zheng DH, Wang XH, et al. Effects of malocclusion on the psychological status of adults. J Shandong Univ. 2014;52(6):94–7.

    Google Scholar 

  5. Jiang JG, Ma XF, Zhang YD, et al. Prediction model and examination of open vertical loop orthodontic force. Arab J Sci Eng. 2019;44(2):1489–99.

    Article  Google Scholar 

  6. Liu CJ, You WJ, Chen QF. Comparison of the effects of two different ligation methods on the anterior and posterior arch planes when the T-loop is closed in the active wing treatment technique. Prim Med Forum. 2017;28:3877–8.

    Google Scholar 

  7. Wang S, Qin K. Comparison of two methods of closing the extraction space using straight wire appliance. Chin J Pract Stomatol. 2011;4(6):359–61.

    Google Scholar 

  8. Wu HP. Clinical study on technical activities wing correction closing tooth extraction gap of. Chin J Aesthet Med. 2015;24(17):42–5.

    Google Scholar 

  9. Chen YM, Li YR, Zhang C. Comparison the torque of upper incisors using two closing loops in the treatment of classII division 1 malocclusion. Hebei Medicine. 2007;13(6):655–7.

    Google Scholar 

  10. Huang CY. Treatment of 21 cases of adult An’s II~1 malocclusion with high and low T-loop. Guangxi Med. 2010;32(3):293–4.

    Google Scholar 

  11. Zhang YL. Observation of clinic effect of t-bending on the correction of incisors cross-bite during mixed dentition period. J Kunming Med Univ. 2008;30(2):206–7.

    Google Scholar 

  12. Jiang JG, Ma XF, Zuo SH, et al. Digital expression and interactive adjustment method of personalized orthodontic archwire for robotic bending. J Adv Mech Design Syst Manuf. 2019;13(2):18–59.

    Google Scholar 

  13. Deng H, Xia ZY, Weng SK, et al. Motion planning and control of a robotic system for orthodontic archwire bending. IEEE/RSJ Int Conf Intell Robots Syst. 2015;2015:3729–34.

    Google Scholar 

  14. Teruko TY, Kiyo S, Goudarzi F, et al. Synergistic acceleration of experimental tooth movement by supplementary high-frequency vibration applied with a static force in rats. Sci Rep. 2017;7(1):13969.

    Article  Google Scholar 

  15. Tochigi K, Oda S, Arai K. Influences of archwire size and ligation method on the force magnitude delivered by nickel-titanium alloy archwires in a simulation of mandibular right lateral incisor linguoversion. Dent Mater J. 2015;34(3):388–93.

    Article  PubMed  Google Scholar 

  16. Ayumi SM, Takehito O, Mikihito H, et al. Osteocyte regulation of orthodontic force-mediated tooth movement via RANKL expression. Sci Rep. 2017;7(1):8753.

    Article  Google Scholar 

  17. Pascal G, Laurence J. Stiffness in bending of a superelastic Ni-Ti orthodontic wire as a function of cross-sectional dimension. Angle Orthod. 2004;74(5):691–6.

    Google Scholar 

  18. Cai YQ. Finite element analysis of archwire parameters and activation forces on the M/F ratio of vertical, L- and T-loops. BMC Oral Health. 2020;20(1):70.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Arora V, Sharma R, Chowdhary S. Comparative evaluation of treatment effects between two fixed functional appliances for correction of Class II malocclusion: a single-center, randomized controlled trial. Angle Orthod. 2018;88(3):259–66.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Zhang JY. Orthodontic treatment of dentition sparse and repair of small teeth in 8 cases. Guangxi Med. 2009;31(2):291–2.

    Google Scholar 

  21. Jiang JG, Ma XF, Zhang YD, et al. Study on three-dimensional digital expression and robot bending method of orthodontic archwire. Appl Bion Biomech. 2018;2018:1–10.

    Google Scholar 

  22. Duan YF, Xiong L, Feng L, et al. Retrospective study of 100 recurrent patients after orthodontics. Stomatology. 2005;25(3):156–7.

    Google Scholar 

  23. Li XG, Liu SC, Xiao YY, et al. Different orthodontic forces on the root development of rat molars. Chin J Conserv Dent. 2018;28(8):450–4.

    Google Scholar 

  24. Ya M, Eri K, Justin F, et al. Excessive orthodontic force induces odontoclastogenesis in root cementum as evidenced by the expression of RANK/RANK. Int J Oral-Med Sci. 2011;8(1):38–46.

    Google Scholar 

  25. Wu JL, Liu YF, Wei P, et al. A biomechanical case study on the optimal orthodontic force on the maxillary canine tooth based on finite element analysis. J Zhejiang Univ Sci B. 2018;19(7):535–46.

    Article  PubMed  PubMed Central  Google Scholar 

  26. Gu M, Li JZ, Liang R, et al. The Typodont investigation of the effect on orthodontic intrusion of upper anterior teeth. J Clin Stomatol. 2004;20:435–7.

    Google Scholar 

  27. Nunez DW, Taleghani M, Wathen WF, et al. Typodont versus live patient: predicting dental students’ clinical performance. J Dent Educ. 2012;76:407–13.

    Article  PubMed  Google Scholar 

  28. Liu YF, Zhang Q, Zhou D, et al. Mechanical properties and resistance characteristic of orthodontic wax models. J Funct Mater Dev. 2015;21(6):181–7.

    Google Scholar 

  29. Zheng M, Du W. Phase behavior, conformations, thermodynamic properties, and molecular motion of multicomponent paraffin waxes: a Raman spectroscopy study. Vib Spectrosc. 2006;40(2):219–24.

    Article  Google Scholar 

  30. Higa RH, Henriques JFC, Janson G, et al. Force level of small diameter nickel-titanium orthodontic wires ligated with different methods. Prog Orthod. 2017;18(1):21–4.

    Article  PubMed  PubMed Central  Google Scholar 

  31. Lin XP. Basic biomechanical principles of orthodontic treatment. Anal Biomech Clin Orthodontics. 2012;5(1):8–9.

    Google Scholar 

  32. Jiang JG, Huang ZY, Ma XF, et al. Establishment and experiment of utility archwire dynamic orthodontic moment prediction model. IEEE Trans Biomed Eng. 2019;67(7):58–68.

    Google Scholar 

  33. Jiang JG, Chen HJ, Huang ZY, et al. Orthodontic force prediction model of T-loop closing spring based on dynamic resistance model. Proc Inst Mech Eng [H]. 2020;234(7):095441192094343.

    Google Scholar 

  34. Laviana A. The effect of different α and β gable on stainless steel and TMA segmental T-loop on the resulting force – an in vitro study. IOP Conf Series: Mater Sci Eng. 2019;550: 012039.

    Article  Google Scholar 

  35. Spyridon NP, Ludger K, Istabrak H, et al. Effect of material variation on the biomechanical behaviour of orthodontic fixed appliances: a finite element analysis. The Eur J Orthodontics. 2015;38(3):300–7.

    Google Scholar 

  36. Zhang XF, Wang C, Xia X, et al. Three-dimensional finite element biomechanical analysis of lingual inward maxillary anterior teeth with the fine wire arch technique. West China J Stomatol. 2015;33(3):291–5.

    Google Scholar 

  37. Ren Y, Maltha JC, Hof MAV, et al. Optimum force magnitude for orthodontic tooth movement: a mathematic model. Am J Orthod Dentofac Orthop. 2004;125(1):71–7.

    Article  Google Scholar 

  38. Guan LY, Wu LP. Photoelastic study and clinical application of orthodontic force and tooth movement. J Jilin Univ Technol. 1997;27(2):5.

    Google Scholar 

  39. Yao S, Zhang LJ, Wang GP, et al. Comparison of mechanical properties of different orthodontic wires and their clinical significance. J Mod Denty. 2000;14(2):92–3.

    Google Scholar 

  40. Li QH, Wang YR, Xiong GP. Construction of 3D finite element model using the customized lingual bracket system during retracting maxillary anterior teeth. J Clin Stomatol. 2016;32(8):462–4.

    Google Scholar 

  41. Wu J, Liu Y, Wei P, et al. Initial orthodontic force analysis of shape memory polymer archwire based on finite element simulation. Chin J Biomed Eng. 2016;35(2):202–10.

    Google Scholar 

  42. Cai Y, Yang X, He B, et al. Finite element method analysis of the periodontal ligament in mandibular canine movement with transparent tooth correction treatment. BMC Oral Health. 2015;15(1):106–17.

    Article  PubMed  PubMed Central  Google Scholar 

  43. Viecilli RF, Budiman A, Burstone CJ. Axes of resistance for tooth movement: does the center of resistance exist in 3-dimensional space. Am J Orthod Dentofac Orthop. 2013;43(2):163–72.

    Article  Google Scholar 

  44. Fuck LM, Drescher D. Force systems in the initial phase of orthodontic treatment-a comparison of different leveling arch wires. J Orofac Orthop-Fortschritte Der Kieferorthop. 2006;67(1):6–18.

    Article  Google Scholar 

  45. Jiang JG, Ma XF, Han YS, et al. Experimentation and simulation of second sequential loop orthodontic moment prediction modeling. IEEE Access. 2018;6:56258–68.

    Article  Google Scholar 

  46. Ding R, Man YN, Wu PL, et al. Establishment of a three-dimensional finite element model of transmission straight wire appliance. Chin J Tissue Eng Res. 2013;17(33):5942–8.

    Google Scholar 

  47. Kinzinger G, Syrée C, Fritz U. Molar distalization with different pendulum appliances: in vitro registration of orthodontic forces and moments in the initial phase. J Orofac Orthop. 2004;65(5):389–409.

    Article  PubMed  Google Scholar 

  48. Lapatki BG, Bartholomeyczik J, Ruther P, et al. Smart bracket for multi-dimensional force and moment measurement. J Dental Res. 2007;86(1):73–8.

    Article  Google Scholar 

Download references

Acknowledgements

This study was supported by Heilongjiang Provincial Natural Science Foundation of China (Grant No. LH2021E081), the Fundamental Research Foundation for Universities of Heilongjiang Province (Grant No. LGYC2018JQ016).

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Contributions

All authors made substantial contributions to the present study. JGJ, LY, XFM and YFG contributed to conception and design, acquisition of data, analysis and interpretation of data; they were, moreover, involved in writing and editing the manuscript. In details, LY reconstructed a 3D model of the maxilla and dental row by reverse CBCT images, and performed simulation analysis of the FEM; XFM realized the measurement experiment of tooth movement by a waxy model in a water-bath environment; YFG analyzed and interpreted all data: together, they were the major contributors in preparing and writing the manuscript. JGJ, YDZ and YL contributed to the conception of the study and revised the manuscript. All authors have read and approved the manuscript.

Corresponding author

Correspondence to Jingang Jiang.

Ethics declarations

Ethics approval and consent to participate

The study design was approved by the Medical Ethics Committee of the 2nd Affiliated Hospital of Harbin Medical University. And all methods and procedures in this paper were conducted in accordance with relevant guidelines and regulations, as well as the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. Furthermore, this paper does not contain any studies performed by any of the authors on animals. It is noteworthy that according to the ethical standards and the approval of the Medical Ethics Committee of the 2nd Affiliated Hospital of Harbin Medical University, all participants provided verbal informed consent.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jiang, J., Yao, L., Zhang, Y. et al. Establishment, FEM analysis and experimental validation of tooth movement prediction model of orthodontic archwire T-loop. BMC Oral Health 22, 406 (2022). https://doi.org/10.1186/s12903-022-02430-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12903-022-02430-9

Keywords