Skip to main content

The effect of scanning pathways on trueness and precision in full-arch optical impression

Abstract

Background

In this study, we investigated the effects of differences in scanning pathways during optical impression on the trueness and precision of full-arch impressions.

Methods

Reference data were obtained using a laboratory scanner. All optical impressions were measured across the dental arch using TRIOSĀ® 3 in four different pathways. The reference and optical impression data were superimposed using the best-fit method. The criteria for superimposition were based on the starting side of the dental arch (partial arch best-fit method, PB) and based on the full arch (full arch best-fit method, FB). The data were compared between the left and right molars (starting and ending sides). The scan deviations for trueness (nā€‰=ā€‰5) and precision (nā€‰=ā€‰10) were obtained for each group by calculating the root mean square (RMS) of the deviation at each measurement point. Visual observations using superimposed color map images revealed variations in trueness.

Results

There were no significant differences in scanning time or amount of scan data between the four scanning pathways. Trueness did not differ significantly among the four pathways with respect to the starting and ending sides, regardless of the superimposition criteria. Precision with PB was significantly different between scanning pathways A and B, and pathways B and C for the starting sides, and between scanning pathways A and B, and pathways A and D for the ending sides. In contrast, there was no significant difference between the starting and ending side in pathways for FB. Regarding PB, color map images showed a large error range in the direction toward the molar radius for the occlusal surface and cervical regions on the ending sides.

Conclusion

Differences in the scanning pathways did not affect trueness, regardless of the superimposition criteria. On the other hand, differences in the scanning pathways affected the precision of the starting and ending sides with PB. Scanning pathways B and D were more precise on the starting and ending sides, respectively.

Peer Review reports

Background

In recent years, advances in digital technology have led to the digitization of prosthetic devices in the dental industry, centered on computer-aided design (CAD)/computer-aided manufacturing (CAM) systems. The production process consists of four main steps. The first step is to obtain an impression of the abutment tooth and dental arch; the second step is to digitize the model; the third step is to design a prosthetic device using CAD software; and the fourth step is to fabricate the prosthetic device using CAM, which is a method to indirectly digitize information in the oral cavity [1, 2]. Optical impression technology, which uses intraoral scanners (IOS) to directly digitize information in the oral cavity, has recently attracted attention [3,4,5]. An IOS can quickly build a three-dimensional model by capturing still images or videos of hard and soft tissues. The optical impression method is characterized by a shortened chair time that is more comfortable for patients because of less gagging with limited vomiting reflexes and oral opening function, prevention of infection and reduction in the use of materials, elimination of the need for storage space owing to the digitalization of impressions, and easy communication with the technical laboratory personnel.

Many studies on optical impression methods applied in crown prosthesis have focused on the compatibility of single crowns or short-span bridges with approximately four units [6,7,8]. With single-tooth optical impressions, the precision reported for IOS is comparable to that of conventional methods using silicone impression materials [9]. For short-span scans and implant-based prosthetic treatments, the risk of error with digitization is reportedly low [10, 11]. In recent years, there has been an increase in the precision of full-arch procedures requiring long-span reconstruction. Such cases are common in the clinical setting. However, an increase in measurement errors has been reported with an increase in the length of the measured teeth [2, 12]. An invitro study showed that the full-arch optical impression method had the same precision as that of conventional impression methods [13], although others have concluded that its precision is lower than that of conventional methods [6, 14, 15].

Factors contributing to scanning data error with IOS include differences in the scanning approach [16,17,18], IOS image type (photo or video), presence or absence of powder [19, 20], size of the scanner head [21], hand abrasions during scanning, and patient movement. These factors influence the scanning pathway for the full-arch. Many IOS from various manufacturers have suggested full-arch scanning pathways. However, several aspects of its applicability remain unclear. Therefore, the effect of differences between scan pathways on the accuracy of full-arch and tooth-level measurements has not been sufficiently investigated.

In this study, we investigated the effects of differences in scanning pathways during optical impressions on the trueness and precision of full-arch impressions.

Methods

Reference model

This study considered teeth located in the lower jaw, and a mandibular model (D-18-500H (GUB) -MF: NISSIN, Kyoto, Japan) was used as the reference model. Reference data were acquired by scanning the reference model with a dental scanner (D2000: 3 Shape, Copenhagen, Denmark).

Measurement method

IOS

In this study, TRIOSĀ® 3 (3 Shape, Copenhagen, Denmark) was used as the IOS, with the confocal method as the scanning principle. Scanning was performed according to the manufacturerā€™s instructions without any powder. Prior to scanning, the scanner tip was calibrated and preheated as instructed by the manufacturer.

Scan environment

The reference model assumed real clinical situations and mimicked patients placed in a dental unit (SIMPLE MANIKIN: NISSIN, Kyoto, Japan) (Fig. 1). The height of the unit was set to 50 cm from the floor so that the occlusal plane was horizontal and the back plate was inclined at 30Ā°.

Fig. 1
figure 1

Scan environment. The reference model was set in a sitting position so that the occlusal plane was horizontal with the floor

Scanning pathways and the time/amount of data

Optical impressions involved the operator being positioned in front of the patient (8 o'clock position). The entire dental arch was measured five times each in four different scanning pathways (A, B, C, and D) from the left mandibular second molar (starting side) to the right mandibular second molar (ending side) (Fig. 2).

Fig. 2
figure 2

Four scanning pathways. Pathway A: Scan in the order of occlusal surface, buccal, and lingual sides. Pathway B: Scan in the order of occlusal surface, lingual side, and buccal side. Pathway C: Scan in a single sextant unit. Pathway D: Scan in an S-shape for each tooth. ā“ˆ mark is the starting point (left second molar), and ā’ŗ mark is the end point (right second molar)

In pathway A, scanning was performed in the order of occlusal, buccal, and lingual surfaces. In pathway B, scanning was performed in the order of occlusal, lingual, and buccal surfaces. In pathway C, scanning was performed in the same order as that of pathway B for a single sextant up to the left mandibular first molar, and a series of scans were performed for a single sextant unit for the front and right mandibular molars. In pathway D, scanning was performed in an S-shape across all the teeth in single-tooth order on the lingual side, occlusal surface, and buccal side. The time required for scanning and amount of data acquired were recorded for each scan. The scans were performed sequentially without repeatedly stopping or resuming. All scans were performed by a dentist who was adequately experienced in scanning. After scanning, the images were confirmed to be unbroken and smooth digital images and were considered scans of acceptable quality for inclusion in the study.

Image analysis and data evaluation

All scan data were input into a CAD software (Dental System: 3 Shape, Copenhagen, Denmark) and converted to stereolithography (STL) data. Subsequently, the data were imported using 3D measurement software (Dmat3DE: DIGITAL PROCESS LTD., Kanagawa, Japan). After trimming excess soft tissue areas, such as gingiva, the data were superimposed using the best-fit method (vote-based pose estimation). Vote-based pose estimation is an algorithm that is used for 3D data superimposition [22]. In this method, the polygons of the entire dataset with minimal deviations are used for superimposition. The criteria for superimposition were set for two patterns, based on either the starting side of the dental arch (partial-arch best-fit method (PB)) or the full arch (full-arch best-fit method (FB)). The trueness of the starting- and ending-side molars was determined by superimposing the scan data of each scanning pathway with the reference scan data (nā€‰=ā€‰5).

The precision was superimposed between the scan data for each scanning pathway (nā€‰=ā€‰10). The precision was compared by combining two of the five measured data points. Therefore, the number of data points per scan pathway was 10.

Additionally, the color map image after superimposition for trueness was used to visually observe the deviation trend and determine theā€‰Ā±ā€‰deviation between the two datasets. The deviation ranges of the starting and ending molars were visually observed, and the area of the greatest deviation in the color map of single-tooth units was selected as the representative value. Deviations included positive and negative values, with positive values shown as warm-colored, and reference data shown as convex (enlarged). In contrast, the negative values are cold-colored and the reference data are shown as pits (minimized). The minimum range of deviation (green area) was set toā€‰Ā±ā€‰50 Āµm and the maximum deviation value was set toā€‰Ā±ā€‰500 Āµm.

Statistical analysis

Statistical analyses were performed using the Mannā€“Whitney U test and Kruskalā€“Wallis test to examine the effect of each scanning pathway on the trueness and precision of FB and PB with a significance level of 5%.

Results

Scanning time and amount of scan data

The results are shown in Table 1. The mean scanning time was 78.4ā€‰Ā±ā€‰4.5 s for scanning pathway A, 87.6ā€‰Ā±ā€‰4.3 s for scanning pathway B, 76.2ā€‰Ā±ā€‰1.0 s for scanning pathway C, and 83.2ā€‰Ā±ā€‰7.1 s for scanning pathway D.

Table 1 Average scanning time and data volume for each scanning pathway

The average scanning time was less than 90 s, the average scanning data amount (slices) was approximately 1100 slices in all scan pathways, and there was no significant difference between the scan pathways.

The mean amount of scan data was 1,065.2ā€‰Ā±ā€‰22.6 for scanning pathway A, 1,168.2ā€‰Ā±ā€‰58.8 for scanning pathway B, 1,055.0ā€‰Ā±ā€‰44.0 for scanning pathway C, and 1,108.8ā€‰Ā±ā€‰51.3 for scanning pathway D.

Scan deviation due to different scanning pathways

The results of the scanning deviations for each group are shown as box plots in Figs. 3, 4, 5 and 6. The box plot contains 25 percentile and 75 percentile values of the scan deviation (median line, median), and the vertical lines represent the minimum and maximum values.

Fig. 3
figure 3

Scan deviation with PB for each scanning pathway. (Ī±) starting side, (Ī²) ending side. The box plots represent the scan deviation among data from the five test scans of the four scan pathways and the reference scan data (trueness)

Fig. 4
figure 4

Scan deviation with FB for each scanning pathway. (Ī±) starting side, (Ī²) ending side. The box plots represent the scan deviation among data from the five test scans of the four scan pathways and the reference scan data (trueness)

Fig. 5
figure 5

Scan deviation with PB for each scanning pathway. (Ī±) starting side, (Ī²) ending side. The box plots represent the scan deviation between each combination of data from the five test scans of the four scan pathways (precision)

Fig. 6
figure 6

Scan deviation with FB for each scanning pathway. (Ī±) starting side, (Ī²) ending side. The box plots represent the scan deviation between each combination of data from the five test scans of the four scan pathways (precision)

Trueness

For PB, the median starting side trueness was 98.0 Āµm (interquartile rangeā€‰=ā€‰26.0) for scanning pathway A, 89.0 Āµm (interquartile rangeā€‰=ā€‰24.5) for scanning pathway B, 106.0 Āµm (interquartile rangeā€‰=ā€‰9.5) for scanning pathway C, and 105.0 Āµm (interquartile rangeā€‰=ā€‰14.0) for scanning pathway D. The median ending side trueness was 190.0 Āµm (interquartile rangeā€‰=ā€‰46.0) for scanning pathway A, 196.0 Āµm (interquartile rangeā€‰=ā€‰52.0) for scanning pathway B, 222.0 Āµm (interquartile rangeā€‰=ā€‰53.0) for scanning pathway C, and 183.0 Āµm (interquartile rangeā€‰=ā€‰57.0) for scanning pathway D. The median starting side trueness was approximately 100 Āµm (interquartile rangeā€‰=ā€‰9.5ā€“26.0) across all the scanning pathways. In contrast, the median ending- side trueness was approximately 200 Āµm (interquartile rangeā€‰=ā€‰46.0ā€“57.0) across all scanning pathways, and the deviation was greater than that of the starting side trueness. In addition, there was no significant difference in trueness between the starting and ending sides for any scanning pathway (Fig. 3).

For FB, the median starting side trueness was 105.0 Āµm (interquartile rangeā€‰=ā€‰27.0) for scanning pathway A, 99.0 Āµm (interquartile rangeā€‰=ā€‰32.5) for scanning pathway B, 110.0 Āµm (interquartile rangeā€‰=ā€‰8.0) for scanning pathway C, and 112.0 Āµm (interquartile rangeā€‰=ā€‰14.0) for scanning pathway D. The median ending side trueness was 95.0 Āµm (interquartile rangeā€‰=ā€‰44.5) for scanning pathway A, 114.0 Āµm (interquartile rangeā€‰=ā€‰44.5) for scanning pathway B, 82.0 Āµm (interquartile rangeā€‰=ā€‰20.0) for scanning pathway C, and 117.0 Āµm (interquartile rangeā€‰=ā€‰37.0) for scanning pathway D. The median starting-side trueness was approximately 100 Āµm (interquartile rangeā€‰=ā€‰8.0ā€“32.5) across all the scanning pathways. In contrast, the median ending side trueness was approximately 100 Āµm (interquartile rangeā€‰=ā€‰20.0ā€“44.5) across all the scan pathways, and although the interquartile range was large, it was similar in size to the starting side trueness. In addition, there was no significant difference in trueness between the starting and ending sides for any of the scanning pathways (Fig. 4).

Precision

For PB, the starting side precision had median values of 38.5 Āµm (interquartile rangeā€‰=ā€‰7.0) for scanning pathway A, 28.0 Āµm (interquartile rangeā€‰=ā€‰6.0) for scanning pathway B, 44.5 Āµm (interquartile rangeā€‰=ā€‰22.0) for scanning pathway C, and 34.5 Āµm (interquartile rangeā€‰=ā€‰15.0) for scanning pathway D. Significant differences were observed between scanning pathways A and B, and between pathways B and C. For PB, the ending side precision had median values of 134.0 Āµm (interquartile rangeā€‰=ā€‰79.0) for scanning pathway A, 83.5 Āµm (interquartile rangeā€‰=ā€‰51.0) for scanning pathway B, 104.5 Āµm (interquartile rangeā€‰=ā€‰36.0) for scanning pathway C, and 89.0 Āµm (interquartile rangeā€‰=ā€‰28.0) for scanning pathway D. The median starting side precision was approximately 35 Āµm (interquartile rangeā€‰=ā€‰6.0ā€“22.0) across all the scanning pathways. However, the median ending side precision was approximately 103 Āµm (interquartile rangeā€‰=ā€‰28.0ā€“79.0) across all the scanning pathways. Significant differences were observed between scanning pathways A and B, and between pathways A and D (Fig. 5).

For FB, the starting side precision had a median value of 52.0 Āµm (interquartile rangeā€‰=ā€‰29.0) for scanning pathway A, 41.0 Āµm (interquartile rangeā€‰=ā€‰19.0) for scanning pathway B, 51.0 Āµm (interquartile rangeā€‰=ā€‰29.0) for scanning pathway C, and 41.5 Āµm (interquartile rangeā€‰=ā€‰12.0) for scanning pathway D. The ending side precision had a median value of 54.0 Āµm (interquartile rangeā€‰=ā€‰20.0) for scanning pathway A, 52.5 Āµm (interquartile rangeā€‰=ā€‰34.0) for scanning pathway B, 48.5 Āµm (interquartile rangeā€‰=ā€‰14.0) for scanning pathway C, and 51.5 Āµm (interquartile rangeā€‰=ā€‰14.0) for scanning pathway D. The median starting side precision was approximately 46 Āµm (interquartile rangeā€‰=ā€‰12.0ā€“29.0) across all the scanning pathways. In contrast, the median ending side precision was approximately 50 Āµm (interquartile rangeā€‰=ā€‰14.0ā€“34.0) across all the scanning pathways; although the interquartile range was large, it was similar in size to the starting side precision. In contrast to the PB, there was no significant difference between the starting and ending sides for any of the scanning pathways (Fig. 6).

Color map images and deviation distribution

Figures 7 and 8 show the color maps generated by superimposing the trueness values. Tables 2, 3, 4 and 5 show the largest ranges of the color map trueness values using single-tooth units as representative values.

Fig. 7
figure 7

Representative example of color-coded deviation maps (trueness) between the reference and digital models for PB. (Ī±) starting side: The deviation showed a range ofā€‰Ā±ā€‰50 Ī¼m among all the scanning pathways, (Ī²) ending side: The deviation range was -150 to -450 Ī¼m on the occlusal and buccal cervical regions

Fig. 8
figure 8

Representative examples of color-coded deviation maps (trueness) between the reference and digital models for FB. (Ī±) starting side: The deviation mostly showed a range ofā€‰+ā€‰50 toā€‰+ā€‰150 Ī¼m for all the scanning pathways, (Ī²) ending side: The deviation showed a scattered range ofā€‰Ā±ā€‰50 toā€‰Ā±ā€‰250 Ī¼m for all the scanning pathways

Table 2 Deviation distribution by tooth for PB starting side (trueness)
Table 3 Deviation distribution by tooth for the PB ending side (trueness)
Table 4 Deviation distribution by tooth for the FB starting side (trueness)
Table 5 Deviation distribution by tooth for the FB ending side (trueness)

With PB, the starting side trueness mostly showed a range ofā€‰Ā±ā€‰50 Āµm for all the scanning pathways (Table 2). For the ending side, the deviation primarily ranged from -150 to -450 Āµm on the occlusal surface and buccal cervical regions (Table 3). This negative trend was particularly strong toward the molar distal region (Fig. 7).

With FB, the starting side trueness mostly showed a range ofā€‰+ā€‰50 toā€‰+ā€‰150 Āµm for all the scanning pathways (Table 4). The ending side trueness showed a scattered range ofā€‰Ā±ā€‰50 toā€‰Ā±ā€‰250 Āµm for all the scanning pathways (Fig. 8) (Table 5).

Discussion

Setting scanning pathway

In this study, we investigated the effect of scanning pathway on the trueness and precision of full-arch optical impressions, assuming long-span reconstruction. Past studies on optical impressions have been based on metal models made of Co-Cr alloys and Ti to minimize the deformation of focal dental models [1, 13, 23]. However, metallic reference models produce strong reflections on the surface of the models during scanning, which can result in a loss of data and scan failure. Therefore, an epoxy resin model with minimal reflection and high dimensional stability was used as the reference model [24]. Optical impressions were obtained using reference models attached to mannequins placed in the dental unit to mimic standard patient conditions [25]. To suppress the reflection of the model surface as much as possible during the scan, non-shadow lamps were avoided in favor of natural lighting according to the manufacturerā€™s instructions.

In this study, four pathways were chosen to scan the optical impressions. In all the pathways, scanning was performed from the left mandibular second molar occlusal surface [26] to facilitate stitching during scanning. Scanning pathways A and B were initially common only to the occlusal surface, but we also scanned the opposite molar regions. When using optical impression for prosthetics, it is recommended that the scanning range should not exceed a single sextant [2, 27, 28]. Accordingly, pathway C was scanned as a single sextant unit. Finally, pathway D was scanned in single-tooth units, either in an S-shaped or zigzag pattern [23, 24], primarily to allow for effective scanning of the anterior teeth. We did not perform a single broad scan for pathways C or D. Instead, we scanned a single sextant or tooth-by-tooth. Thus, the four scanning pathways can be separated into two large scanning ranges that operate simultaneously. Therefore, this study allowed us to consider how differences in the scanning range (distance) affect the trueness and precision of three-dimensional data.

Best-fit method

Post-scan three-dimensional data were superimposed on reference data or acquired data using three-dimensional measurement software after conversion to STL data. The D2000Ā® dental laboratory scanner (3 Shape, Copenhagen, Denmark) used to scan the reference model adopted a multiline scanning method using blue light-emitting diode (LED) light with a scanning precision ofā€‰Ā±ā€‰5 Āµm. Unlike IOSs, dental laboratory scanners can measure a wide range of angles using high-performance cameras while shielding from natural light. Thus, this technology allows us to obtain high-precision data and has been used in several studies to obtain reference data [12].

Several studies have reported the trueness and precision of optical impression superimposition, citing three-dimensional data obtained using best-fit methods [2, 4, 15, 23, 28,29,30,31]. The characteristics of this method include visual representation of the entire three-dimensional model depression, making it possible to assess displacement by color mapping [1, 10, 14, 32].

However, this method is not suitable for evaluating errors at particular points (such as the distances between the centers of multiple ball abutments). Therefore, a best-fit algorithm has not been used in implantology research. Rather, these studies were evaluated by determining the central coordinates of two ball abutments and calculating the distance between them [12, 29]. A disadvantage of this method is that the variation within the entire model cannot be evaluated stereoscopically because the error is evaluated as the distance between the central coordinates at arbitrary points. This method may also lack reproducibility and incorporate measurement bias [29, 31]. In this study, data superimpositions were performed using the aforementioned best-fit algorithm, which allowed the assessment of dentition for studying optical impression methods in a fixed prosthodontic region.

Selecting best-fit method criteria

Most studies using the best-fit algorithm overlapped with the full arch using the least-squares method [14, 33]. When using the least squares method for superimposition, the software adjusts the parameters such that there are no significant deviations or variations in the data as a whole. Therefore, this method is suitable for assessing whether the target and reference objects are similar in shape. In this study, we used vote-based pose estimation, which is a best-fit algorithm. In this method, polygons of the entire dataset with minimal errors were used for superimposition. In this case, polygons with large errors were not used for superimposition, resulting in small areas with small deviations and large areas with large deviations.

Therefore, this method is suitable for measuring the deviations between datasets. The algorithm most likely attempted to register the surfaces such that the overall mean deviation between the surfaces was minimized, which may conceal an increase in deviation between the surfaces and make the interpretation of the deviation difficult. A best-fit algorithm based only on areas where the scan started may show an increase in deviation [16]. In this study, a scan with the left molar region as the starting side and a full-arch scan were performed to create two reference superimpositions.

Effects on scanning time and data amount

The scanning time was shorter than that of conventional methods using silicone impression materials for all the scanning pathways [25]. In addition, the amount of scanned data did not exceed the upper limit (2000 slices) for optimal post-scan data transmission, and the scan path settings used in this study were considered appropriate for standard clinical applications.

Effects on scanning pathway trueness

The IOS accuracy was assessed primarily using two measures: ā€œtruenessā€ and ā€œprecisionā€ (ISO 5725ā€“1) [34]. Trueness is defined as the deviation from reference data values [13, 34,35,36].

There was no significant difference between the starting and ending sides for either PB or FB for any of the scanning pathways. Depending on the digital system, there have been reports [30] that show no effect of the different scanning pathways on trueness. Another report [24] suggests that the trueness and precision of TRIOSĀ®, OmnicamĀ®, and 3 Mā„¢ True Definition Scanner are unaffected by the differences in scanning method when recording impressions over long spans. These results are consistent with the findings of this study. Therefore, in this study, the degree of authenticity was not affected by differences in scanning pathways. Many previous studies used the second-generation TRIOSĀ® Pod or TRIOSĀ® Color [2,3,4,5,6, 9, 12]. In this study, the third-generation TRIOSĀ® 3 was used. Although there were differences in scan speed and system version, TRIOSĀ® 3 had the common scanning principle and was powderless.

PB and FB trueness showed similar values for the starting side; however, for PB, the trueness of the ending side was lower than that of FB.

Effects on scanning pathway precision

Precision may refer to reproducibility and is defined as a measure of how close similar values are to each other, independent of the reference data [13, 34,35,36]. There was no significant difference in precision between the starting and ending sides of PB for any scanning pathway. In addition, there was no significant difference in precision between the starting sides and ending sides of FB for any scanning pathway.

The scan deviation at the starting side of PB showed the highest precision with scanning pathway B. Significant differences were observed in precision between scanning pathways A and B, and between pathways B and C. MĆ¼ller et al. investigated the effect of three scanning pathways on optical impression trueness and precision using TriosĀ® Scanner with a maxillary full-arch model [23]. In their study, after scanning the occlusal and palatal sides, the scan pathway on the buccal side showed the highest precision, which is consistent with the results of our study. Scanning pathways in the order of the occlusal surface, palatal side, and buccal side have been reported to eliminate the risk of increasing errors when using linear data acquisition over a longer distance. Therefore, regarding the precision of the starting side, it is believed that scanning pathway B displays similarly high precision as scanning pathway A, which first scans a wide range. The scan deviation of the ending side of PB showed the highest precision for scanning pathway D. Significant differences were observed in precision between scanning pathways A and B, and between pathways A and D. Factors influencing deviation among the molars of the ending side included increased scan distance and scanning of the anterior teeth. Large deviations at the radial end of the scan data have been reported because of the accumulation of overlapping deviations in the anterior dental region [10]. The fact that anterior teeth are structurally simple makes accurate stitching of data particularly difficult [6, 14]. It was suggested that reducing the scan range, such as for scanning pathways C and D, may reduce the deviation in the anterior region compared with a wider scan. Finally, pathway D, which involved wide scanning, showed higher precision than pathway A.

For FB, the precision on the starting side was approximately the same as that on the ending side, and no significant difference was observed.

In addition, similar precision was observed for PB and FB on the starting side, as was the case with trueness. However, in the case of PB, the precision on the ending side was lower than that of FB.

Trueness color map image deviation trends

Superimposed trueness data are displayed in a color map format. As the starting side was considered as standard for the superimposition of PB trueness, the starting side trueness frequently showed a range ofā€‰Ā±ā€‰50 Āµm for all the scanning pathways. For the ending side, the deviation mainly ranged from -150 to -450 Āµm on the occlusal surface and buccal cervical regions.

Previous studies have reported that TRIOSĀ® shows the largest deviation in the molar region and tends to marginally underestimate the reference file [35]. This finding is consistent with the results of the present study.

The trueness of FB was in the range ofā€‰+ā€‰50 toā€‰+ā€‰150 Āµm, with the majority of the deviation on the starting side. On the ending side, the deviation ranged fromā€‰Ā±ā€‰50 toā€‰Ā±ā€‰250 Āµm. In addition, the degree of deviation was strong enough to tend toward the molar distal regions. Many studies using superimposed full-arch color map images have reported large displacements in both the vertical and horizontal directions in the radial molar region of the ending side [4, 10, 14, 23, 29, 37]. It has also been reported that deviation from the occlusal surface increases owing to the strong effect of factors such as image overlap and still image skill [26]. Similarly, in this study, we believe that the deviation range of the ending side showed a strong tendency toward vertical or horizontal displacement of the occlusal surface and the cervical region, tending toward the distal region.

Clinical significance

In this study, the trueness and precision of the full arch could be evaluated on the ending side when the two datasets were superimposed. On the ending side, the trueness of PB was 183.0ā€‰~ā€‰222.0 Āµm, and that of FB was 82.0ā€‰~ā€‰117.0 Āµm. The precision of PB was 83.5ā€‰~ā€‰134.0 Āµm, and that of FB was 48.5ā€‰~ā€‰54.0 Āµm. The accuracy of optical impressions for full-arch teeth has been reported to be within an acceptable range of 250 Āµm or less [26]. Thus, it was suggested that there is no issue with the reproducibility for jaws with teeth.

In contrast, the trueness and precision of the partial arch can be evaluated on the starting side, where the two datasets are superimposed. For the starting side, the trueness of PB was 89.0ā€‰~ā€‰106.0 Āµm and that of FB was 99.0ā€‰~ā€‰112.0 Āµm. The precision of PB was 28.0ā€‰~ā€‰44.5 Āµm, and that of FB was 41.0ā€‰~ā€‰52.0 Āµm, indicating a higher precision than that for full arch. This suggests that the partial-arch prosthesis range is more accurate than the full-arch range. If the final prosthetic device is within the range of one sextant, it is ideal to perform a scan.

Visual observation of color map images for trueness indicated that the starting side trueness for PB ranged betweenā€‰Ā±ā€‰50 Āµm and the starting side trueness for FB ranged fromā€‰+ā€‰50 toā€‰+ā€‰150 Āµm. From these results, it can be inferred that in the case of FB, the abutment teeth were expressed to a slightly greater extent.

In contrast, the trueness of ending side of PB ranged from -150 to -450 Āµm, and the trueness of ending side of FB ranged fromā€‰Ā±ā€‰50 to 250 Āµm. From these results, it can be inferred that a one-sided prosthesis with better trueness may be superimposed by PB. Furthermore, FB is preferred if a bilateral prosthesis is present. Because the color map was visually observed from only one direction (the buccal side), the actual displacement of the lingual-side data was unclear. Therefore, in future studies it is necessary to observe from other directions.

In addition, the scan deviation results and color map image observations did not necessarily match. The scan deviations are expressed as absolute deviations. However, the color map image is in single-tooth units, with the largest color map trueness range as a representative value. Therefore, we need to evaluate the results of both scanning pathways for trueness impact.

In this study, the abutment teeth were not prepared in the model because natural dentition was assumed. It has been reported that the shape of the prepared abutment teeth surface may affect the accuracy of the optical impression [33], and that scanning of the mucosal and subgingival areas is difficult [3, 21]. It is important to investigate the shape and margin of the abutment teeth and mucosal deficiencies.

A limitation of this study was that all scans were performed by a single dentist. Although the dentist was well-trained before scanning the models, operator bias during scanning cannot be excluded. Five scans were performed for each scan pathway, which may not be statistically significant in case of relatively large differences between the compared groups. This needs to be tested because increasing the number of scans may increase the detection power. Furthermore, this study was conducted in vitro, and factors that could affect the scans, such as saliva or moving soft tissues present in the actual oral cavity, were absent. Therefore, these factors were not considered in this study. In a study analyzing the in vivo trueness and precision of the maxillary dental arch, the authors reported that when the entire arch was superimposed, there was no specific error pattern in color-mapped images with TRIOSĀ® 3 precision, and the errors could not be localized to a specific area or side of the dental arch [38]. Therefore, clinical conditions may show error patterns different from those obtained in this experiment, and the effects of different scan pathways need to be tested in vivo.

Conclusions

In this study, two superimposition criteria for PB and FB were used for 3D optical impression data using four scan pathways. The trueness and precision of the starting and ending sides of the molar were evaluated. The experiments produced the following results:

  1. 1.

    The scans using the four scan pathways in this study were within the clinically acceptable range in terms of scanning time and amount of scan data.

  2. 2.

    The scanning pathways did not affect the trueness of the starting and ending sides both for PB and FB.

  3. 3.

    The scanning pathways affected the precision of the starting and ending sides for PB. Scanning pathways B and D were more precise on the starting and ending sides, respectively. For FB, the scanning pathway did not affect the precision of both the starting sides and ending sides.

Availability of data and materials

Data are available from the corresponding author after approval by all authors.

Abbreviations

PB:

Partial-arch best-fit method

FB:

Full-arch best fit method

RMS:

Root mean square

CAD:

Computer-aided design

CAM:

Computer-aided manufacturing

IOS:

Intraoral scanners

STL:

Stereolithography

References

  1. GĆ¼th JF, Keul C, Stimmelmayr M, Beuer F, Edelhoff D. Accuracy of digital models obtained by direct and indirect data capturing. Clin Oral Invest. 2013;17(4):1201ā€“8.

    ArticleĀ  Google ScholarĀ 

  2. Su TS, Sun J. Comparison of repeatability between intraoral scanner and extraoral digital scanner: an invitro study. J Prosthodont Res. 2015;59(4):236ā€“42.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  3. Kim JE, Amelya A, Shin Y, Shim JS. Accuracy of intraoral digital impressions using an artificial landmark. J Prosthet Dent. 2017;117(6):755ā€“61.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  4. Ender A, Zimmermann M, Attin T, Mehl A. In vivo precision of conventional and digital methods for obtaining quadrant dental impressions. Clin Oral Invest. 2015;20(7):1495ā€“504.

    ArticleĀ  Google ScholarĀ 

  5. Medina-Sotomayor P, Pascual-MoscardĆ³ A, Camps I. Relationship between resolution and accuracy of four intraoral scanners in complete-arch impressions. J Clin Exp Dent. 2018;10(4):e361ā€“6 10.4317.

    PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  6. Ender A, Attin T, Mehl A. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions. J Prosthet Dent. 2016;115(3):313ā€“20.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  7. Ueda K, Beuer F, Stimmelmayr M, Erdelt K, Keul C, GĆ¼th JF. Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions. Clin Oral Invest. 2016;20(2):283ā€“9.

    ArticleĀ  Google ScholarĀ 

  8. Almeida e Sliva J, Erdelt K, Edelhoff D, AraĆŗjo Ɖ, Stimmelmayr M, Vieira LC, et al. Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig. 2014;18(2):515ā€“23.

    ArticleĀ  Google ScholarĀ 

  9. Berrendero S, Salido MP, Valverde A, Ferreiroa A, Pradies G. Influence of conventional and digital intraoral impressions on the fit of CAD/CAM fabricated all ceramic crowns. Clin Oral Invest. 2016;20(9):2403ā€“10.

    ArticleĀ  Google ScholarĀ 

  10. Patzelt SB, Emmanouilidi A, Stampf S, Strub JR, Att W. Accuracy of full-arch scans using intraoral scanners. Clin Oral Invest. 2014;18(6):1687ā€“94.

    ArticleĀ  Google ScholarĀ 

  11. Seelbach S, Brueckel C, Wƶstmann B. Accuracy of digital and conventional impression techniques and workflow. Clin Oral Invest. 2013;17(7):1759ā€“64.

    ArticleĀ  Google ScholarĀ 

  12. Fukazawa S, Odaira C, Kondo H. Investigation of accuracy and reproducibility of abutment position by intraoral scanners. J Prosthodont Res. 2017;61(4):450ā€“9.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  13. Ender A, Mehl A. Full arch scans: conventional versus digital impressions ā€“ an in-vitro study. Int J Comput Dent. 2011;14(1):11ā€“21.

    PubMedĀ  Google ScholarĀ 

  14. Ender A, Mehl A. Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision. J Prosthet Dent. 2013;109(2):121ā€“8.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  15. Atieh MA, Ritter AV, Ko CC, Duqum I. Accuracy evaluation of intraoral optical impressions: a Clinical study using a reference appliance. J Prosthet Dent. 2017;118(3):400ā€“5.

    ArticleĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  16. Van der Meer WJ, Andriessen F, Wismeijer D, Ren Y. Application of intra-oral dental scanners in the digital workflow of implantology. PLoS One. 2012;7(8):e43312 10.137.

    ArticleĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  17. Li H, Lyu P, Wang Y, Sun Y. Influence of object translucency on the scanning accuracy of a powder-free intraoral scanner: A laboratory study. J Prosthet Dent. 2017;117(1):93ā€“101.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  18. Jeon JH, Choi BY, Kim CM, Kim JH, Kim HY, Kim WC. Three-dimensional evaluation of the repeatability of scanned conventional impressions of prepared teeth generated with white- and blue-light scanners. J Prosthet Dent. 2015;114(4):549ā€“53.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  19. Nedelcu RG, Persson AS. Scanning accuracy and precision in 4 intraoral scannersā€Æ: An in vitro comparison based on 3-dimensional analysis. J Prosthet Dent. 2014;112(6):1461ā€“71.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  20. Dehurtevent M, Robberecht L, BĆ©hin P. Influence of dentist experience with scan spray systems used in direct CAD/CAM impressions. J Prosthet Dent. 2015;113(1):17ā€“21.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  21. Hayama H, Fueki K, Wadachi J, Wakabayashi N. Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible. J Prosthodont Res. 2018;62(3):347ā€“52.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  22. Pham M-T, Woodford OJ, Perbet F, Maki A, Gherardi R, Stenger B, Cipolla R. Scale-invariant vote-based 3d recognition and registration from point clouds. Stud Comput Intell. 2013;411:137ā€“62.

    ArticleĀ  Google ScholarĀ 

  23. MĆ¼ller P, Ender A, Joda T, Katsoulis J. Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner. Quintessence Int. 2016;47(4):343ā€“9.

    PubMedĀ  Google ScholarĀ 

  24. Medina-Sotomayor P, Pascual A, Camps I. Accuracy of four digital scanners according to scanning strategy in complete-arch impressions. PLoS One. 2018;13(9):e0202916 10.1371.

    ArticleĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  25. Patzelt SB, Lamprinos C, Stampf S, Att W. The time efficiency of intraoral scannersā€Æ: an in vitro comparative study. J Am Dent Assoc. 2014;145(6):542ā€“51.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  26. Jeong ID, Lee JJ, Jeon JH, Kim JH, Kim HY, Kim WC. Accuracy of complete-arch model using an intraoral video scanner: An in vitro study. J Prosthet Dent. 2016;115(6):755ā€“9.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  27. Wesemann C, Muallah J, Mah J, Bumann A. Accuracy and efficiency of full-arch digitalization and 3D printing: A comparison between desktop model scanners, an intraoralscanner, a CBCT model scan, and stereolithographic 3D printing. Quintessence Int. 2017;48(1):41ā€“50.

    PubMedĀ  Google ScholarĀ 

  28. GĆ¼th JF, Runkel C, Beuer F, Stimmelmayr M, Edelhoff D, Keul C. Accuracy of five intraoral scanners compared to indirect digitalization. Clin Oral Invest. 2017;21(5):1445ā€“55.

    ArticleĀ  Google ScholarĀ 

  29. Kuhr F, Schmidt A, Rehmann P, Wƶstmann B. A new method for assessing the accuracy of full arch impressions in patients. J Dent. 2016;55:68ā€“74 10.1016.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  30. Ender A, Mehl A. Influence of scanning strategies on the accuracy of digital intraoral scanning systems. Int J Comput Dent. 2013;16(1):11ā€“21.

    PubMedĀ  Google ScholarĀ 

  31. Mangano FG, Veronesi G, Hauschild U, Mijiritsky E, Mangano C. Trueness and precision of four intraoral scanners in oral implantology: a comparative in vitro study. PLoS One. 2016;11(9):e0163107 10.1371.

    ArticleĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  32. Nedelcu R, Olssson P, Nystrƶm I, RydĆ©n J, Thor A. Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: a novel in vivo analysis method. J Dent. 2018;69:110ā€“8 10.1016.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  33. Kamimura E, Tanaka S, Takaba M, Tachi K, Baba K. In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques. PLoS One. 2017;12(6):e0179188 10.1371.

    ArticleĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  34. International Organization for Standardization. ISO 5725ā€“1:1994. Accuracy (trueness and precision) of measurement methods and results ā€“ Part 1: general principles and definitions. Geneva: International Organization for Standardization; 1994.

    Google ScholarĀ 

  35. Treesh JC, Liacouras PC, Taft RM, Brooks DI, Raiciulescu S, Ellert DO, et al. Complete-arch accuracy of intraoral scanners. J Prosthet Dent. 2018;120(3):382ā€“8.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  36. Mandelli F, Gherlone E, Gastaldi G, Ferrari M. Evaluation of the accuracy of extraoral laboratory scanners with a single-tooth abutment model: A 3D analysis. J Prosthodont Res. 2017;61(4):363ā€“70.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  37. Vecsei B, JoĆ³s-KovĆ”cs G, BorbĆ©ly J, Hermann P. Comparison of the accuracy of direct and indirect three-dimensional digitizing processes for CAD/CAM systems - An in vitro study. J Prosthodont Res. 2017;61(2):177ā€“84.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  38. Winkler J, Gkantidis N. Trueness and precision of intraoral scanners in the maxillary dental arch: an in vivo analysis. Sci Rep. 2020;10(1):1172.

    ArticleĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

Download references

Acknowledgements

The authors like to thank 3D! company for conducting the image analysis and the support during this study.

Funding

The present in vitro study was not funded or supported by any grants.

Author information

Authors and Affiliations

Authors

Contributions

SK, MY and TS contributed to conception and design, acquisition of data, analysis and interpretation of data; they were, moreover, involved in writing and editing the manuscript. SN statistically analyzed the data and was a major contributor in writing the manuscript. RH and HS revised the manuscript before submission. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Shota Kuroda.

Ethics declarations

Ethics approval and consent to participate

No Ethics Committee approval or consent to participate was requested, as the present was an in vitro study.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisherā€™s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kuroda, S., Yotsuya, M., Sato, T. et al. The effect of scanning pathways on trueness and precision in full-arch optical impression. BMC Oral Health 23, 390 (2023). https://doi.org/10.1186/s12903-023-03101-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12903-023-03101-z

Keywords