Skip to main content

Micro-computed tomography analysis of calcium hydroxide delivery efficacy in C-shaped canal system of mandibular second molars

Abstract

Background

Calcium hydroxide [Ca(OH)2] is widely accepted as a biocompatible interappointment intracanal medicament. This study aimed to analyze the efficacy of Ca(OH)2 placement into the C-shaped canal system of mandibular second molars using the syringe method with and without lentulo spiral utilizing micro-computed tomography (micro-CT).

Methods

Twenty-four extracted mandibular second molars were instrumented and classified into C-shaped floors (n = 12) and non-C-shaped floors (n = 12). Both groups were placed with Ca(OH)2 using the syringe system, then all teeth were scanned and cleaned, and placed with Ca(OH)2 again but with the syringe system followed by lentulo spiral and rescanned. The specimens were scanned using micro-CT to analyze the volume, volume percentage, uncontacted surface area, and uncontacted surface area percentage of Ca(OH)2 with the two delivery methods in the entire canal and at the apical 4 mm of the canal. Mann-Whitney test and Wilcoxon signed-rank test were used to determine the statistical differences among the groups.

Results

Syringe administration used in conjunction with lentulo spiral presented lower uncontacted surface area, a lower percentage of uncontacted surface area, larger volume, and a higher percentage of volume than syringe without lentulo spiral (P < 0.05). There was no significant difference between the C-shaped floor group and the non-C-shaped floor group (P > 0.05) in the Ca(OH)2 uncontacted surface area, volume, and percentages at different regions of canals and among different delivery techniques groups.

Conclusions

The lentulo spiral and syringe technique combination can increase the volume and contacted surface area of Ca(OH)2 in the C-shaped canal system of mandibular second molars.

Peer Review reports

Background

Elimination of microorganisms and their by-products from an infected root canal system is crucial for successful endodontic treatment. However, it has been reported that some microorganisms may remain lodged in the dentinal tubules even after careful chemo-mechanical preparation [1, 2]. Thus, intracanal medication between sessions can be essential for disinfecting the root canal system, minimizing the risk of reinfection, and favoring periapical tissue repair [3, 4].

Calcium hydroxide is highly recommended and widely accepted as a biocompatible interappointment intracanal medicament [5, 6]. Rajasekharan et al. reported that changes in pH, short-term calcium ion release, and maximum release rate were dependent on the exposed surface area, while maximum calcium ion release was dependent on the volume [7]. Therefore, to maximize the penetration and disinfection properties, Ca(OH)2 should ideally be placed deep and in close contact with the canal surface along the working length.

However, the quality of Ca(OH)2 placement may depend on canal morphology, instruments, materials, and the delivery technique [8, 9]. Various techniques for intracanal placement of Ca(OH)2 have been advocated before [8, 10,11,12,13,14,15]. It is considered that syringe techniques are easier to use in clinical settings [12], and the lentulo spiral was reported to produce higher filling quality in minimally instrumented canals [10].

The morphology and complexities of the canal system can also influence the effectiveness of intracanal medicament placement [9]. Mandibular second molars with C-shaped canal configurations are especially commonly found in east Asia [16,17,18]. The main anatomic feature of the C-shaped canal system is the presence of a fin or web connecting the individual root canals, which can harbor many microorganisms even after shaping [19]. Thus, application of intracanal medicament is strongly recommended in these cases.

Traditional methods to verify the quality of Ca(OH)2 placement into complex canals are using radiographic images, clearing process and splitting teeth samples [12, 15, 20]. However, these techniques may exhibit subjectivity, lack quantifiability, and possess low resolution. Furthermore, studies using traditional methods reported controversial results of different delivery techniques, including K-type ultrasonic file, Gutta-Condensor, Pastinject, Lentulo spiral, injection system, et al. [13, 21]. Evaluation was done through scoring by examiners [15, 22], calculation of the density of the intracanal medicament and observation of porosities [8, 10, 13, 14, 23], and weight calculation [21]. No previous studies have investigated the percentage of the contacted and uncontacted canal surface area by Ca(OH)2, which may more clearly show the contact condition between the intracanal medicament and canal surface.

Micro-computed tomography (micro-CT) has been used in endodontic studies to analyze changes in canal volume, surface area, and uninstrumented surface area after canal preparation [24,25,26]. To our knowledge, there have been no studies using micro-CT to evaluate the placement efficacy of Ca(OH)2. In addition, it is unclear whether lentulo spiral has a significant auxiliary effect on increasing the contact area during placement of intracanal medicament by syringes.

Thus, the purpose of this micro-CT study was to analyze the effectiveness of intracanal placement of Ca(OH)2 in C-shaped canals of mandibular second molars using the syringe method with and without lentulo spiral.

Methods

The manuscript of this laboratory study has been written according to Preferred Reporting Items for Laboratory studies in Endodontology (PRILE) 2021 guidelines (Fig. 1) [27].

Fig. 1
figure 1

PRILE 2021 flowchart of Ca(OH)2 placement efficacy in C-shaped canal system

Specimen preparation

80 mandibular second molars from native Chinese patients with fused roots, radicular grooves, and no macroscopically visible external defects were extracted because of severe periodontitis, and were then collected and ultrasonically cleaned. The age and sex were unknown. The study was approved by the university clinical research ethics board (WCHS-IRB-ST-2017-224). The teeth were scanned by micro-CT (µCT-50; Scanco Medical, Brttisellen, Switzerland) at an isotropic voxel size of 30 μm at 90 kVp and 200 mA. All data were exported in DICOM format. The teeth were then three-dimensionally reconstructed using VGStudio MAX 2.0 (Volume Graphics, Heidelberg, Germany) software, and the pulp chamber floor (PCF) was investigated. These teeth were divided into two groups according to a classification based on the shape of the PCF by Min et al. as follows [28]:

C-shaped PCF and orifice: a peninsula-like floor with a continuous or discontinuous C-shaped orifice, which encompasses Types I, II, and III of Min’s classification;

Non-C-shaped PCF and orifice: without peninsula-like floors and with separated mesial and distal canal orifices, similar to Type IV of Min’s classification.

The sample size was calculated based on the data of our pilot study, and the calculation method in a previous study [29]. The analysis was performed using two independent means from the T-­test family in G*Power 3.1 software (Henrick Heine-Universität) with α = 0.05 and 95% power inputs. 10 was considered the minimum sample size to observe significant difference between groups. Considering a low incidence of non-C-shaped PCF canal in fused roots, a final of 24 teeth (12 per group) in the C-shaped PCF and non-C-shaped PCF groups were selected for the study.

Standard access cavities were prepared for all the selected teeth. A size 10 K-type file was introduced into each canal until the tip of the instrument was visualized at the apical foramen when observed under a dental operating microscope (DOM) (Pico; Carl Zeiss, Jena, Germany). Working length (WL) determination was accomplished by subtracting the file 0.5 mm from the total canal length. Root canal preparation was performed using a ProGlider™ Rotary Glide Path File sized 16/0.02 up to Waveone Gold 25/0.07 (Dentsply Maillefer, Ballaigues, Switzerland) mounted on a reciprocating X-Smart Plus motor (Dentsply Maillefer). During mechanical preparation, irrigation was carried out copiously between files with 2 mL of 1% NaOCl. After completion of instrumentation, each canal was irrigated with ultrasonic flush for 30 s using Irrisafe tip (Acteon, Merignac, France), which was inserted to 1 mm short of the WL and activated at 20% power as without cutting power. Each canal was subsequently irrigated with 5 mL 1% NaOCl for 1 min and then dried with paper points.

Intracanal medicament placement

All roots were embedded with 3 M impression material putty (Express XT, 3 M ESPE, St. Paul, MN, USA) to seal the root structure until the cemento enamel junction (CEJ). UltraCal XS Ca(OH)2 paste (Ultradent Products, South Jordan, UT, USA) was applied using the following techniques:

  • Group 1: Syringe system with NaviTip needle.

    The 29-G NaviTip needle (Ultradent Products) was attached to the UltraCal syringe and introduced into the canal 2 mm short of the predetermined canal length. The syringe was then gently pressed and withdrawn from the canal until paste reflow was observed and extrusion was evident at the orifices under DOM. Subsequently, a cotton pellet was applied into the canal orifice with Caviton (GC Corporation, Tokyo, Japan) as the temporary filling material. The teeth were stored at 37 °C and 100% humidity for two weeks. Two weeks after the placement of Ca(OH)2 paste, the impression material was removed. A second micro-CT scan was carried out for further 3D measurement and analysis.

    Subsequently, the impression material was removed to ensure that the apical foramen was unobstructed, as opposed to being in a sealed state as observed clinically. The Ca(OH)2 pastes in all of the teeth were removed using Irrisafe or ET-20 ultrasonic tips powered by a piezoelectric unit (Acteon, Merignac, France). The remaining pastes were further removed using air-scaler-attached EDDY sonic tips (VDW, Munich, Germany), NaOCl, and through a gentle up-and-down motion to ensure free movement of the tips. Then, a final flush was set in an ultrasonic bath (Fisher Scientific Company, Ottawa, Canada). During pilot experiments, these procedures led to nearly complete removal of Ca(OH)2, which was also confirmed by micro-CT inspection; the teeth were then reused in group 2.

  • Group 2: Syringe system with NaviTip needle followed by lentulo spiral.

    Compared with group 1, after injection of Ca(OH)2 paste, a size 25 lentulo spiral (Dentsply Maillefer) attached to a slow-speed handpiece was inserted 1 mm from working length passively in a clockwise direction at 300 rpm for 10 s. The lentulo spiral was removed, and the UltraCal syringe needle was reinserted into the canal. Ca(OH)2 paste was reinjected until paste reflow was observed and extrusion was evident at the orifices under DOM. A cotton pellet was then applied into the canal orifice with Caviton as the temporary filling material. Teeth were stored at 37 °C and 100% humidity for two weeks, and a third micro-CT scan was taken to compare the placement efficacy of different techniques.

Micro-CT image measurement and analysis

The measurement methodology is based on a previously published technique by our research team [30]. The DICOM files obtained from the scanned batches were subjected to 3D co-registration using the Elastix rigid image registration module, integrated into the 3D Slicer software (v4.1.1) (Harvard SPL, Boston, MA, USA). Subsequently, the registered data were imported into VGStudio MAX 2.0 for further processing. A semi-automatic threshold-based segmentation technique was employed to create a 3D model of the canal and Ca(OH)2, allowing for precise measurements (Fig. 2AI, II, III, 2BI, II, III). The region of interest (ROI) for the Ca(OH)2 paste was defined from the canal orifices to 0.5 mm short of the apex (covering the entire canal) and from the canal orifices to the apical 4 mm of the canal.

Fig. 2
figure 2

Micro-CT three-dimensional reconstructions of Ca(OH)2 placement in C-shaped or non-C-shaped PCF mandibular second molars. (A-B) I. Red parts in the models represent the initial post-preparation canal surface area in non-C-shaped PCF and C-shaped PCF, respectively. II-III. grey parts represent Ca(OH)2 that was placed into the canal using different delivery techniques. IV-V. green and red parts represent the surface area of the Ca(OH)2 that was and was not in contact with the initial canal surface, respectively. II, IV. Ca(OH)2 placed with syringes alone. III, V. Ca(OH)2 placed with syringes and lentulo spirals. (C-D) cross-sections views of the coronal, middle and apical thirds of roots

The volume, uncontacted surface area, and their respective proportions relative to the entire canal and the apical 4 mm region were measured. The VGStudio MAX software was employed for the precise measurement of intracanal Ca(OH)2 volume, considering various delivery methods. The determination of the uncontacted surface area of Ca(OH)2 was carried out through the following steps: Initially, the region of interest (ROI), comprising both the canal walls and the surface of intracanal Ca(OH)2, was digitally reconstructed and exported to 3D STL format using VGStudio MAX software. Subsequently, the surface area of the canal wall that came into contact with Ca(OH)2 was computed. This process involved the calculation of the canal surface area and a Boolean intersection using Geomagic Studio 2012 software (Raindrop Geomagic, Morrisville, NC, USA), where each voxel represented 30 μm. In such cases, the Boolean intersection of the canal surface and the contacted surface area of Ca(OH)2 equaled zero:

\({\rm{Ca}}{\left( {{\rm{OH}}} \right)_{\rm{2}}}\,{\rm{uncontacted}}\,{\rm{surface}}\,{\rm{area}}\,\left( {\rm{\% }} \right)\,{\rm{ = }}\)\(=\frac{{\text{C}\text{a}\left(\text{O}\text{H}\right)}_{2}\text{u}\text{n}\text{c}\text{o}\text{n}\text{t}\text{a}\text{c}\text{t}\text{e}\text{d} \text{s}\text{u}\text{r}\text{f}\text{a}\text{c}\text{e} \text{a}\text{r}\text{e}\text{a} \left(\text{i}\text{n} \text{t}\text{h}\text{e} \text{e}\text{n}\text{t}\text{i}\text{r}\text{e} \text{c}\text{a}\text{n}\text{a}\text{l} \text{o}\text{r} \text{a}\text{p}\text{i}\text{c}\text{a}\text{l} 4 \text{m}\text{m}\right)}{ \text{T}\text{o}\text{t}\text{a}\text{l} \text{c}\text{a}\text{n}\text{a}\text{l} \text{s}\text{u}\text{r}\text{f}\text{a}\text{c}\text{e} \text{a}\text{r}\text{e}\text{a} \left(\text{t}\text{h}\text{e} \text{e}\text{n}\text{t}\text{i}\text{r}\text{e} \text{c}\text{a}\text{n}\text{a}\text{l} \text{o}\text{r} \text{a}\text{p}\text{i}\text{c}\text{a}\text{l} 4 \text{m}\text{m}\right)}\)

Statistical analysis

Mann–Whitney test was used to determine the difference between C-shaped and non-C-shaped groups in the volume and the uncontacted surface area of Ca(OH)2 in the entire canal and at the apical 4 mm, and Wilcoxon signed-rank test was used to determine statistical differences between the two different delivery techniques. All statistical tests were performed using SPSS software (SPSS 20.0 for Windows, SPSS, Chicago, IL, USA). A value of p < 0.05 was considered statistically significant.

Results

The delivery technique using syringes followed by lentulo spiral showed significantly higher efficacy of Ca(OH)2 delivery, regarding volume, uncontacted surface area, and their percentages, in both C-shaped and non-C-shaped PCF groups compared with the delivery with syringes alone (Fig. 2). The median (interquartile range) of the uncontacted surface area of Ca(OH)2 after placement with the two techniques in both C-shaped and non-C-shaped PCF groups are shown in Fig. 3. There were statistically significant differences among the two types of delivery techniques in both the C-shaped and non-C-shaped PCF groups (P < 0.001). Specifically, syringe followed with lentulo spiral presented lower uncontacted surface area and a lower percentage of uncontacted surface area than syringe without lentulo spiral, regardless of whether the region of interest encompassed the entire canal (Fig. 3A-B) or the apical 4 mm of the canal (Fig. 3C-D) (P < 0.05).

Fig. 3
figure 3

The uncontacted surface area of Ca(OH)2 with and without using lentulo spiral. (A-B) Uncontacted surface area (mm2) and Uncontacted surface area (%) of the entire canal with C-shaped or non-C-shaped PCF. (C-D) Uncontacted surface area (mm2) and Uncontacted surface area (%) of the apical region with C-shaped or non-C-shaped PCF. *P < 0.05, **P < 0.01, ***P < 0.001

median (interquartile range) of the volume of Ca(OH)2 in the entire canal and apical 4 mm placed with the two techniques in both C-shaped and non-C-shaped PCF groups are shown in Fig. 4. Statistically significant differences were found between the two placement techniques in both C-shaped and non-C-shaped groups, both in the entire canal (Fig. 4A-B) and in the apical 4 mm (Fig. 4C-D) (P < 0.05). Specifically, syringe followed with lentulo spiral showed a larger volume of Ca(OH)2 in the entire canal and at the apical 4 mm.

Fig. 4
figure 4

Ca(OH)2 volume (mm3) and the percentage of volume (%) with and without using lentulo spiral. (A-B) Volume (mm3) and the percentage of volume (%) of Ca(OH)2 in the entire canal with C-shaped or non-C-shaped PCF. (C-D) Volume (mm3) and the percentage of volume (%) of Ca(OH)2 in the apical region with C-shaped or non-C-shaped PCF. *P < 0.05, **P < 0.01, ***P < 0.001

Between the C-shaped and the non-C-shaped PCF groups, there were no statistically significant differences in the mean volume, uncontacted surface area and the percentages for the two delivery techniques, both in the entire canal and at the apical 4 mm (P > 0.05).

Discussion

Ca(OH)2 is the most commonly used intracanal medicament for eliminating residual microorganisms after chemo-mechanical preparation [3, 31]. To obtain the maximum therapeutic benefit of Ca(OH)2, the paste must be in direct contact with the root canal walls to allow penetration of the OH ion and the Ca2+ ion [22]. Therefore, in the assessment of Ca(OH)2 placement, uncontacted surface area and volume of Ca(OH)2 should be essential parameters.

Previous methods used to assess the efficacy of different Ca(OH)2 delivery techniques include scoring by an examiner [15, 22], calculation of the density of Ca(OH)2 and the porosities [8, 10, 13, 14, 23], and weight calculation [21]. However, scoring by different examiners can result in inaccurate results as it is largely subjective. Simcock et al. reported a strong correlation between the radiographic appearance and the weight after Ca(OH)2 delivery into the canal [21]. Calculation of Ca(OH)2 density is unable to show the area where the drug is in effect as it does not show where Ca(OH)2 is directly in contact with the canal surface. Weight calculation before and after delivery of Ca(OH)2 also has a disadvantage that it cannot separately measure the amount of Ca(OH)2 in each portion of the canal, for instance, the apical portion. By using the amount of uncontacted surface area as a parameter, the quality of the application of the medicament on the root canal surface can be represented, especially at the apical portion.

For two decades, micro-CT has widely been used in endodontic research. Imaging software allows researchers to calculate and analyze canal surface area before and after instrumentation. No previous study has used micro-CT for assessing the uncontacted or contacted surface area and volume of Ca(OH)2 medicament in root canals. In the present study, the surface area of Ca(OH)2 was regarded as the pre-preparation area, and the canal surface area was regarded as the post-preparation area. We applied micro-CT scanning to reconstruct a 3D model, which enabled us to calculate and analyze the contacted surface area of the Ca(OH)2 in a more standardized and precise manner.

Ca(OH)2 paste requires effective delivery into the canal to achieve total antibacterial activity. Several techniques are used for Ca(OH)2 placement, among which syringe and lentulo spiral are commonly advocated clinically [23]. Staehle et al. stated that the syringe system provided superior filling quality with Ca(OH)2 in straight or lightly curved root canals; the addition of the lentulo spiral was reportedly more effective in filling curved canals [12]. Similar results were also reported in other studies [8, 31, 32].

UltraCal XS Ca(OH)2 paste is a commonly used commercial paste with a syringe system. NaviTip syringe TM is relatively small and can be inserted into the apex of root canals. Thus, two delivery techniques were utilized in the present study, namely NaviTip syringe and NaviTip syringe used in conjunction with lentulo spirals. The results of our study indicated that using lentulo spirals can help to reduce the uncontacted surface area of Ca(OH)2 in root canals. This is in agreement with Torre et al.’s study, which compared Ultradent tips, Ultradent tips used in conjunction with lentulo spiral, and lentulo spiral used alone [14]. Their results showed that Ultradent tips used in conjunction with lentulo spiral and lentulo spiral alone were significantly more effective than Ultradent tips alone in the apical 3 mm and 1 mm. Similarly, the syringe-lentulo spiral group in the study by Tan et al. showed a greater mean radiodensity than the syringe-#25 finger spreader group at all levels [23]. As expected in our study, differences in delivery techniques resulted in variations in the uncontacted surface area of Ca(OH)2 in both the C-shaped canal systems with C-shaped PCF and non-C-shaped PCF. The group in which NaviTip syringe was used in conjunction with lentulo spiral showed a significantly lower uncontacted surface area. This could be due to the rotation of the lentulo spiral, which may help to remove small, entrapped air bubbles within the canal and spread the Ca(OH)2 into the irregular isthmuses and fins in C-shaped canals, thus allowing better distribution and contact of Ca(OH)2 with the canal surfaces.

Apart from delivery techniques, the placement quality of Ca(OH)2 also depends on the canal morphology. C-shaped canal systems that usually consists of 2 or 3 “main” canals interconnected with fins and isthmuses in the form of a C-configuration in cross section of the root have been reported to have large amounts of debris and uninstrumented areas after preparation [19, 33,34,35]. Studies have shown that the use of rotary instruments does not improve the situation and no preparation was evident at the interconnecting fins or isthmuses which especially highlights the importance of intracanal medication [36]. Furthermore, the continuously aging of the east Asia population would further complicate this question that not only endodontists but also general dentists may face more and more root canal therapy (RCT) cases related to C-shaped canals owing to extensive caries or abrasion.

Most of the previous studies that focused on intracanal medication delivery techniques were related to the placement of Ca(OH)2 into straight and large canals or artificial curved canals(21, 23, 37). No comparable data were reported in C-shaped canals. Therefore, in the present study, mandibular second molars with C-shaped canal system were used to assess the effect of complex canal anatomy on the placement quality of Ca(OH)2. Based on our pilot study, most of the Ca(OH)2 was removed from the canals after cleaning protocol abovementioned, and the canal space showed no statistical differences to the primary volume, therefore, in the current study, the samples were reused in the lentulo spiral groups to minimize the differences caused by the complex C-shaped canal morphology. There may be potential differences in the pre-medicament baseline in the two techniques, nevertheless, any discrepancies arising from the minute remaining paste were considerably smaller than using an entirely different tooth for comparison. In addition, owing to the C-shaped canal serving as a perfect and well-known ‘complex model’, research methods reported on C-shaped canal systems in this study can also be easily adapted to other studies about other complex human hard tissue anatomy or benchmark quests from the industrial community about related clinical procedures, such as ultrasonic activation/irrigation benchmark test described in this study [38].

The findings of our study indicated that under the investigated conditions, the uncontacted surface area was not influenced by the shape of the PCF in the group filled with the NaviTip syringe system and NaviTip syringe used in conjunction with lentulo spirals. This finding broadly supports the work of Rahde et al., who reported that the curvature did not influence the filling quality of Ca(OH)2 into extracted human teeth [20]. However, conflicting results were reported by Sharifi et al., who found that the curvature affected the density of Ca(OH)2 [9]. An explanation for this disparity could be the differences in experimental specimens. Sharifi et al. used simulated canals in resin block to assess the effect of the canal curvature while Rahde used extracted human first molars and single-rooted teeth [9, 20].

Contrary to expectations, this study did not find a significant difference in the uncontacted surface area of Ca(OH)2 between C-shaped and non-C-shaped PCF groups. Such results may be attributed to the complexity of the root canal systems, as numerous ramifications and isthmuses can exist in C-shaped canal systems with C-shaped and non-C-shaped PCF. Development of novel delivery techniques is needed to improve the application of intracanal medicament in C-shaped canals.

This study showed that an appropriate delivery technique is essential for the clinical application of Ca(OH)2 for canal disinfection, especially in complex canal anatomies. The limitation of the study is the small sample size and only one kind of Ca(OH)2 pastes, and another limitation is that we used only C-shaped canal system and it may take caution to extrapolate the results to other canals.

Conclusions

Although complete contact between Ca(OH)2 and the canal surface is not yet possible, the combination technique of lentulo spiral and syringe can significantly increase the contacted surface of the root canal wall by Ca(OH)2 in C-shaped canal system of mandibular second molars.

Data availability

The datasets used and/or analysed during the current study are available from the corresponding author [Jingzhi Ma and Yuan Gao] on reasonable request.

References

  1. Gazzaneo I, Vieira GCS, Pérez AR, Alves FRF, Gonçalves LS, Mdala I, et al. Root canal disinfection by single- and multiple-instrument systems: effects of sodium hypochlorite volume, concentration, and retention time. J Endod. 2019;45:736–41.

    Article  PubMed  Google Scholar 

  2. Zandi H, Rodrigues RCV, Kristoffersen AK, Enersen M, Mdala I, Ørstavik D, et al. Antibacterial effectiveness of 2 root canal irrigants in root-filled teeth with infection: a randomized clinical trial. J Endod. 2016;42:1307–13.

    Article  PubMed  Google Scholar 

  3. Bystrom A, Claesson R, Sundqvist G. The antibacterial effect of camphorated paramonochlorophenol, camphorated phenol and calcium hydroxide in the treatment of infected root canals. Endod Dent Traumatol. 1985;1:170–5.

    Article  PubMed  Google Scholar 

  4. Leonardo MR, da Silva LAB, Utrilla LS, de Toledo Leonardo R, Consolaro A. Effect of intracanal dressings on repair and apical bridging of teeth with incomplete root formation. Endod Dent Traumatol. 1993;9:25–30.

    Article  PubMed  Google Scholar 

  5. Chong BS, Pitt Ford TR. The role of intracanal medication in root canal treatment. Int Endod J. 1992;25:97–106.

    Article  PubMed  Google Scholar 

  6. Kawashima N, Wadachi R, Suda H, Yeng T, Parashos P. Root canal medicaments. Int Dent J. 2009;59:5–11.

    PubMed  Google Scholar 

  7. Rajasekharan S, Vercruysse C, Martens L, Verbeeck R. Effect of exposed surface area, volume and environmental pH on the calcium ion release of three commercially available tricalcium silicate based dental cements. Mater (Basel). 2018;11:123.

    Article  Google Scholar 

  8. Peters CI, Koka RS, Highsmith S, Peters OA. Calcium hydroxide dressings using different preparation and application modes: density and dissolution by simulated tissue pressure. Int Endod J. 2005;38:889–95.

    Article  PubMed  Google Scholar 

  9. Sharifi R, Bahrampour E, Janfroozzade P, Safaei M, Mozaffari HR, Soltanimehr E, et al. Comparative evaluation of the efficacy of three methods of delivering calcium hydroxide into the root canal. Dent Med Probl. 2019;56:155–9.

    Article  PubMed  Google Scholar 

  10. Sigurdsson A, Stancill R, Madison S. Intracanal placement of ca(OH)2: a comparison of techniques. J Endod. 1992;18:367–70.

    Article  PubMed  Google Scholar 

  11. Rivera EM, Williams K. Placement of calcium hydroxide in simulated canals: comparison of glycerin versus water. J Endod. 1994;20:445–8.

    Article  PubMed  Google Scholar 

  12. Staehle HJ, Thoma C, Muller HP. Comparative in vitro investigation of different methods for temporary root canal filling with aqueous suspensions of calcium hydroxide. Endod Dent Traumatol. 1997;13:106–12.

    Article  PubMed  Google Scholar 

  13. Deveaux E, Dufour D, Boniface B. Five methods of calcium hydroxide intracanal placement: an in vitro evaluation. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2000;89:349–55.

    Article  PubMed  Google Scholar 

  14. Torres CP, Apicella MJ, Yancich PP, Parker MH. Intracanal placement of calcium hydroxide: a comparison of techniques, revisited. J Endod. 2004;30:225–7.

    Article  PubMed  Google Scholar 

  15. Smutkeeree A, Phajongviriyatorn P, Komoltri C, Jantarat J. Calcium hydroxide medication in primary molars using different preparations and placement techniques: an in vitro study. Eur Arch Paediatr Dent. 2015;16:313–8.

    Article  PubMed  Google Scholar 

  16. Fernandes M, de Ataide I, Wagle R. C-shaped root canal configuration: a review of literature. J Conserv Dent. 2014;17:312–9.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Zheng Q, Zhang L, Zhou X, Wang Q, Wang Y, Tang L, et al. C-shaped root canal system in mandibular second molars in a chinese population evaluated by cone-beam computed tomography. Int Endod J. 2011;44:857–62.

    Article  PubMed  Google Scholar 

  18. Wu YC, Su WS, Mau LP, Cheng WC, Weng PW, Tsai YC, et al. Association between the presence of distolingual root in mandibular first molars and the presence of C-shaped mandibular second molars: a CBCT study in a taiwanese population. Quintessence Int. 2020;51:798–807.

    PubMed  Google Scholar 

  19. Ma JZ, Shen Y, Al-Ashaw AJ, Khaleel HY, Yang Y, Wang ZJ, et al. Micro-computed tomography evaluation of the removal of calcium hydroxide medicament from C-shaped root canals of mandibular second molars. Int Endod J. 2015;48:333–41.

    Article  PubMed  Google Scholar 

  20. Rahde Nde M, Figueiredo JA, Oliveira EP. Influence of calcium hydroxide points on the quality of intracanal dressing filling. J Appl Oral Sci. 2006;14:219–23.

    Article  PubMed  Google Scholar 

  21. Simcock RM, Hicks ML. Delivery of calcium hydroxide: comparison of four filling techniques. J Endod. 2006;32:680–2.

    Article  PubMed  Google Scholar 

  22. Oztan MD, Akman A, Dalat D. Intracanal placement of calcium hydroxide: a comparison of two different mixtures and carriers. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2002;94:93–7.

    Article  PubMed  Google Scholar 

  23. Tan JM, Parolia A, Pau AK. Intracanal placement of calcium hydroxide: a comparison of specially designed paste carrier technique with other techniques. BMC Oral Health. 2013;13:52.

    Article  PubMed  PubMed Central  Google Scholar 

  24. Esenturk G, Akkas E, Cubukcu E, Nagas E, Uyanik O, Cehreli ZC. A micro-computed tomographic assessment of root canal preparation with conventional and different rotary files in primary teeth and young permanent teeth. Int J Paediatr Dent. 2020;30:202–8.

    Article  PubMed  Google Scholar 

  25. Drukteinis S, Peciuliene V, Dummer PMH, Hupp J. Shaping ability of BioRace, ProTaper NEXT and genius nickel-titanium instruments in curved canals of mandibular molars: a MicroCT study. Int Endod J. 2019;52:86–93.

    Article  PubMed  Google Scholar 

  26. Espir CG, Nascimento-Mendes CA, Guerreiro-Tanomaru JM, Cavenago BC, Hungaro Duarte MA, Tanomaru-Filho M. Shaping ability of rotary or reciprocating systems for oval root canal preparation: a micro-computed tomography study. Clin Oral Investig. 2018;22:3189–94.

    Article  PubMed  Google Scholar 

  27. Nagendrababu V, Murray PE, Ordinola-Zapata R, Peters OA, Rôças IN, Siqueira JF Jr., et al. PRILE 2021 guidelines for reporting laboratory studies in endodontology: a consensus-based development. Int Endod J. 2021;54:1482–90.

    Article  PubMed  Google Scholar 

  28. Min Y, Fan B, Cheung GS, Gutmann JL, Fan M. C-shaped canal system in mandibular second molars part III: the morphology of the pulp chamber floor. J Endod. 2006;32:1155–9.

    Article  PubMed  Google Scholar 

  29. Silva EJNL, Lima CO, Barbosa AFA, Moreira T, Souza EM, De-Deus G, et al. Influence of access cavity preparation on the dentine thickness of mesial canals of mandibular molars prepared with reciprocating instruments. Int Endod J. 2022;55:113–23.

    Article  PubMed  Google Scholar 

  30. Yang X, Wang Y, Ji M, Li Y, Wang H, Luo T, et al. Microcomputed tomographic analysis of the efficiency of two retreatment techniques in removing root canal filling materials from mandibular incisors. Sci Rep. 2023;13:2267.

    Article  PubMed  PubMed Central  Google Scholar 

  31. Galvao T, Camargo B, Armada L, Alves F. Efficacy of three methods for inserting calcium hydroxide-based paste in root canals. J Clin Exp Dent. 2017;9:e762–6.

    PubMed  PubMed Central  Google Scholar 

  32. Walia T, Ghanbari AH, Mathew S, Ziadlou AH. An in vitro comparison of three delivery techniques for obturation of root canals in primary molars. Eur Arch Paediatr Dent. 2017;18:17–23.

    Article  PubMed  Google Scholar 

  33. Cooke HG 3rd, Cox FL. C-shaped canal configurations in mandibular molars. J Am Dent Assoc. 1979;99:836–9.

  34. Fan B, Cheung GS, Fan M, Gutmann JL, Bian Z. C-shaped canal system in mandibular second molars: part I–Anatomical features. J Endod. 2004;30:899–903.

    Article  PubMed  Google Scholar 

  35. Melton DC, Krell KV, Fuller MW. Anatomical and histological features of C-shaped canals in mandibular second molars. J Endod. 1991;17:384–8.

    Article  PubMed  Google Scholar 

  36. Cheung LH, Cheung GS. Evaluation of a rotary instrumentation method for C-shaped canals with micro-computed tomography. J Endod. 2008;34:1233–8.

    Article  PubMed  Google Scholar 

  37. Aragão AC, Pintor AVB, Marceliano-Alves M, Primo LG, Silva ASS, Lopes RT, et al. Root canal obturation materials and filling techniques for primary teeth: in vitro evaluation in polymer-based prototyped incisors. Int J Paediatr Dent. 2020;30:381–9.

    Article  PubMed  Google Scholar 

  38. Minarik M, Stundl J, Fabian P, Jandzik D, Metscher BD, Psenicka M, et al. Pre-oral gut contributes to facial structures in non-teleost fishes. Nature. 2017;547:209–12.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We thank LetPub (www.letpub.com) for its linguistic assistance and scientific consultation during the preparation of this manuscript.

Funding

This study was supported by the Funding of the Science & Technology Department of Sichuan Province (No.2023NSFSC0554) and the National Natural Science Foundation of China (No. 62373263 and No. 62171193).

Author information

Authors and Affiliations

Authors

Contributions

Xuedong Zhou, Dingming Huang, Jingzhi Ma and Yuan Gao conceived of the study and designed research. Min Chen, Babita Pradhan, and Yajun Meng performed research and collected the data. Min Chen and Babita Pradhan analysed data. Min Chen wrote the paper. Chialing Tsauo and Yuan Gao revised the paper.

Corresponding authors

Correspondence to Jingzhi Ma or Yuan Gao.

Ethics declarations

Ethics approval

The human mandibular molars used in this study were obtained from the Outpatient Department of Oral Surgery, West China Hospital of Stomatology, Sichuan University. All methods were carried out in accordance with relevant guidelines and regulations. The study was approved by the West China Hospital of Stomatology Institutional Review Board (WCHS-IRB-ST-2017-224). All samples were collected from hospitals as medical waste following tooth extractions due to various reasons, including severe periodontitis. The patients had previously signed consent forms for the extractions. We collected these samples and used them for our experiments. The Sichuan University West China School of Stomatology Ethics Committee approved the use of these extracted teeth for in vitro experiments, as the protocols were not performed on patients and therefore did not require additional informed consent.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chen, M., Pradhan, B., Meng, Y. et al. Micro-computed tomography analysis of calcium hydroxide delivery efficacy in C-shaped canal system of mandibular second molars. BMC Oral Health 24, 59 (2024). https://doi.org/10.1186/s12903-023-03450-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12903-023-03450-9

Keywords