Skip to main content

Evaluation of two treatment concepts of four implants supporting fixed prosthesis in an atrophic maxilla: finite element analysis

Abstract

Background

Currently, oblique placement of long implants or the use of short implants to circumvent the maxillary sinus area and provide support for fixed prostheses are viable alternatives. The purpose of this study was to compare these two treatment concepts and ascertain which one exhibits superior biomechanical characteristics.

Methods

Two different treatment concept models were constructed. The first one, LT4I, consisting of two mesial vertical implants positioned in lateral incisor regions and two distal tilted implants (45°) situated in second premolar regions of the maxilla. The second model, VS4I, includes two mesial vertical implants in lateral incisor regions and two vertically positioned short implants in second premolar regions. Numerical simulations were conducted under three loading types: firstly, oblique forces upon the molars; secondly, vertical forces upon the molars; thirdly, oblique forces upon the incisors. The maximum principal stress (σmax) and minimum principal stress (σmin) of the bone, as well as von Mises stress of the implants, were calcuated.

Results

Under oblique loading on the molar, higher stress values in the bone were observed in LT4I group. Under vertical loading on molar, higher stress values in the bone were also observed in LT4I group. Furthermore, little difference was found between the two groups under oblique loading on the incisor.

Conclusion

Both treatment concepts can be applicable for edentulous individuals with moderate atrophic maxilla. Compared to tilted implants, short implants can transmit less occlusal force to the supporting tissues.

Peer Review reports

Introduction

The fixed prosthesis of atrophic jaws with dental implants has been considered a clinical challenge [1], as it involves complex three-dimensional (3D) anatomic structure such as the maxillary sinus and nasal cavity, making surgical procedures more difficult [2]. Moreover, the process of reabsorption in the maxilla results in both vertical and horizontal loss of alveolar bone, and tooth loss can further lead to sinus pneumatization, adding to the complexity of the surgery [2, 3]. Additionally, the observation of low bone quality and volume in moderate atrophic maxilla is quite common [4]. These potential complications significantly restrict the width, number, length, and positioning of the implants to be used, ultimately affecting the final treatment outcome [5]. To make implantation in posterior regions possible, maxillary sinus elevation and bone grafting are commonly performed at the implant placement site to restore bone height [3, 6]. However, this approach carries a high risk of surgical complications, such as infection and perforation of the maxillary sinus mucosa, as well as increased costs and prolonged treatment duration [1, 7].

P Maló et al. suggested that employing four implants (two in the anterior region, and two tilted ones in the posterior region of the alveolar bone, named all-on-4) could serve as an alternative to bone grafting procedures [8]. Clinical studies have shown promising results for the all-on-4 treatment concepts [9, 10]. Furthermore, studies have demonstrated that the use of short implants may also serve as a viable alternative to bone graft surgeries, with favorable clinical outcomes [6, 11]. Both treatment concepts have high implant survival rate [10, 12]. Nevertheless, we remain unaware of the superior treatment approach, and it behooves us to employ finite element analysis (FEA) to assess the two above treatment.

Numerous scholars have conducted FEA of various treatment options for fixed prosthesis. Initially, Chiara M.Bellini et al. used simplistic models to compare the effects of all-on-4 and all-on-5 (five vertical implants) on the mandible, revealing no significant disparity in stress values [13]. A.S. Bonnet et al. demonstrated that the location of food has an effect on stress concentration in bone for the all-on-4 concept, especially on bone-implant interface [14]. Afterwards, several scholars explored the impact of implant angles and cantilever length in all-on-4 treatment. They found that the use of tilted implants can cause increased stress on the cortical bone around the implants. And the use of tilted implants combined with a short cantilever in the all-on-4 concept reduces the stress around the implant on cortical bone [15, 16]. While previous researches have predominantly focused on all-on-4 concept, scant attention has been paid to the application of short implants in the atrophic maxilla. In recent biomechanical studies, Erika O. Almeida group and Cláudia Lopes Brilhante Bhering group explored the utilization of short implants in edentulous maxilla [1, 5]. However, it is worth noting that the short implants used in the posterior maxilla in these studies followed the all-on-6 treatment concept rather than the all-on-4 treatment concept. Therefore, when bone height is limited in the posterior region, it remains uncertain whether the placement of short implants surpasses that of tilted implants. Furthermore, their studies could be enhanced by considering the anisotropic nature of bone properties [14]. And the occlusal force referred in previous studies only set for molars but without incisors [5, 17].

This study, via different bite loading settings and appropriate anisotropic parameters of bone, compared the biomechanical property of these two treatment concepts and ascertain which one exhibits superior biomechanical characteristics. Two different treatment concept models were constructed as described below: The initial model, LT4I, consisting of two mesial vertical implants positioned in lateral incisor regions and two distal tilted implants (45°) situated in second premolar regions of the maxilla. The second one, VS4I, includes two mesial vertical implants in lateral incisor regions and two vertically positioned short implants in second premolar regions. The proposed conjectures are as follows: (1) The level of stress in the peri-implant regions of short vertical implants is anticipated to be lower than that of tilted long ones in the maxilla. (2) Different occlusal force settings may lead to diverse biomechanical behavior on bone-implant interface.

Materials and methods

Model design

An examination using cone beam computerized tomography (CBCT, KaVo 3D eXam, Imaging Science International, USA, resolution 0.400 mm, field of view 130 mm, acceleration voltage 120 kV, beam current 5 mA, exposure time 8.9 s) was conducted to acquire the atrophic maxillary bony structure. In the posterior region of maxilla, the distance between the wall of maxillary sinus floor and the residual alveolar ridge was about 7.50 mm [18]. The CBCT data files, formatted as DICOM, were imported into Mimics 17 (Materialise, Leuven, Belgium) to reconstruct the maxillary model. The maxillary and overdenture models were then modified based on literature with professional software Geomagic Studio 12 (Geomagic Company, NC, USA). The finite maxillary model possessed dimensions of 15 mm in height, 50 mm in length and 90 mm in width. The thickness of cortical bone was 1 mm, and the residual bone was trabecular bone [19, 20]. The final prosthetic model ranges from the left first molar to the right first molar, including 12 teeth. Its dimension was 8 mm in height, 34 mm in length and 55 mm width.

Nobel implants (Nobel Speed Groovy, Nobel Biocare, Yorba Linda, CA, USA), abutments and screws were chosen for this biomechanical analysis. The Nobel Biocare implants are recommended by Maló who first introduced the all-on-4 concept in 2003 [8]. The 3D geometry of the implants, abutments and screws were modeled with Solidworks 2014 (SolidWorks Corporation, Ve lizy-Villacoublay, France). The implants, abutments and prostheses were reconstructed jointly in the maxillary model according to the clinical situation. Two treatment concepts models were constructed, each involving four implants to support fixed prostheses: (1) TL4I group - two mesial implants (4.1 mm in diameter and 11.5 mm in length) were located vertically in lateral incisor regions and two distal implants (4.1 mm in diameter and 13.0 mm in length ) were located in second premolar regions and tilted at a 45-degree angle toward the anterior regions. (2) VS4I group - two mesial implants were the same as the ones of TL4I group and two distal short implants (5.0 mm in diameter and 7.0 mm in length) were placed vertically in second premolar regions. The prostheses utilized in both groups were the same. The locations and characteristic of the implants and abutments are showed in Table 1 and Fig. 1.

Table 1 The locations and characteristic of the implants and abutments
Fig. 1
figure 1

The prostheses and implant positioning on 3D models of the TL4I group (A: occlusal view; B: frontal view; C: lateral view) and VS4I group (D: occlusal view; E: frontal view; F: lateral view).

Meshing procedure and material properties

The 3D models were imported into the ANSYS Workbench 17.0 software (Ansys Inc., Canonsburg, PA, USA) for generating meshes and defining material properties. The models were meshed using 10 node tetrahedral elements with a size of 1.5 mm. Furthermore, the tetrahedral elements were adjusted to accommodate all the small feature such as bone-implant interface. The TL4I groups presented a total of 156,854 elements and 274,862 nodes and the VS4I groups presented a total of 134,913 elements and 234,913 nodes. The mesh generation of groups are showed in Fig. 2. The models consist of cortical bone, trabecular bone, implants, abutments, central screws, prosthesis screws, and prostheses. Cortical and trabecular bone are anisotropic tissues [21]. The material properties of the rest models were assumed to be isotropic, homogeneous and linearly elastic and all material properties are showed in Table 2 [22].

Fig. 2
figure 2

Finite element mesh for the TL4I group (A: frontal view; C: lateral view) and the VS4I group (B: frontal view; D: lateral view). The models consist of cortical bone, trabecular bone, implants, abutments, central screws, prosthesis screws, and prostheses.

Table 2 Material properties of models

Boundary and loading conditions

The maxillary models were submitted to a strict fixation restriction in its upper area [1]. The implants were considered entirely osseointegrated [21]. And the cortical bone was bonded to the trabecular bone. The abutments were fixed in the implants through central screws. Their interfaces considered fixed together. The interfaces between prosthesis and abutments were also considered fixed together.

To simulate the occlusal force on the maxilla, three loading types were set in ANSYS Workbench 17.0. The first loading type was that tilting load of 150 N was imposed unilaterally on the posterior teeth with 30° in the buccal direction [23]. The teeth contacting with the loading surface were the right first premolar, right second premolar and right first molar. The second loading type was that vertical load of 150 N was imposed on the posterior teeth. The teeth contacting with the loading surface were the same to the first type [23]. The third loading type was that oblique load of 150 N was imposed on bilateral central incisors, at a 45° angle with the long axis of the incisors [24]. The loading types are presented in Fig. 3.

Fig. 3
figure 3

Three types of loading setting: (1) oblique loading on molars (A: loading direction; D: corresponding loading region); (2) vertical loading on molars (B: loading direction; E: corresponding loading region); (3) oblique loading on incisors (C: loading direction; F: corresponding loading region).

Stress analysis

FEA was analyzed by ANSYS Workbench 17.0. To distinguish the tensile stress from the compressive stress, the maximum and minimum principal stresses (σmax and σmin) were selected as the stress output of the cortical and trabecular bone [5]. The mesial, distal, buccal, and lingual σmax and σmin values of the bone around the implant were recorded and analyzed [25]. Von Mises stress(σVM) was selected for implants.

Result

Oblique load on molars

Under oblique loading on molars, TL4I group exhibited higher stress concentration than VS4I groups. The σmax and σmin values of bone are showed in Table 3. Both groups demonstrated a similar distribution of stress, with the σmax and σmin mainly concentrated on the cortical bone. Particularly, the peak σmax and σmin value were observed around the distal implant, especially in the distal and buccal areas. In addition, the TL4I group exhibited a peak σmax value of 58.33 MPa in the cortical bone, approximately 1.33 times higher than that of the VS4I group. Similarly, the peak σmin value of the cortical bone was 80.16 MPa in TL4I group, approximately 1.87 times than that in VS4I group (Figs. 4A-C and 5A-C). The stress distribution in the trabecular bone was found to be similar in both groups (Figs. 6A-C and 7A-C). In terms of implants, the σVM mainly concentrated on the neck proportion. The maximum σVM value of implant in TL4I group was 76.49 MPa, which was 26.5% higher than that of the VS4I group (Fig. 8A-C).

Table 3 Summary of data obtained from TL4I and VS4I groups under oblique load on molars
Fig. 4
figure 4

Maximum principal stress (σmax) distribution (MPa) in the cortical bone for the TL4I group (A: oblique load on molars; D: vertical load on molars; G: oblique load on incisors) and VS4I group (B: oblique load on molars; E: vertical load on molars; H: oblique load on incisors). The peak σmax values of three loading types (C: oblique load on molars; F: vertical load on molars; I: oblique load on incisors) for the two groups.

Fig. 5
figure 5

Minimum principal stress (σmin) distribution (MPa) in the cortical bone for TL4I group (A: oblique load on molars; D: vertical load on molars; G: oblique load on incisors) and VS4I group (B: oblique load on molars; E: vertical load on molars; H: oblique load on incisors). The peak σmin values of three loading types (C: oblique load on molars; F: vertical load on molars; I: oblique load on incisors) for the two groups.

Fig. 6
figure 6

Maximum principal stress (σmax) distribution (MPa) in the trabecular bone for TL4I group (A: oblique load on molars; D: vertical load on molars; G: oblique load on incisors) and VS4I (B: oblique load on molars; E: vertical load on molars; H: oblique load on incisors) groups. The peak σmax values of three loading types (C: oblique load on molars; F: vertical load on molars; I: oblique load on incisors) for the two groups.

Fig. 7
figure 7

Minimum principal stress (σmin) distribution (MPa) in the trabecular bone for TL4I group (A: oblique load on molars; D: vertical load on molars; G: oblique load on incisors) and VS4I group (B: oblique load on molars; E: vertical load on molars; H: oblique load on incisors). The peak σmin values of three loading types (C: oblique load on molars; F: vertical load on molars; I: oblique load on incisors) for the two groups.

Fig. 8
figure 8

Von Mise stress (σVM) distribution (MPa) in the trabecular bone for TL4I group (A: oblique load on molars; D: vertical load on molars; G: oblique load on incisors) and VS4I group (B: oblique load on molars; E: vertical load on molars; H: oblique load on incisors). The peak σVM values of three loading types (C: oblique load on molars; F: vertical load on molars; I: oblique load on incisors) for the two groups.

Vertical load on molars

Under condition of vertical loading on molars, the TL4I group also showed a higher degree of stress concentration compared to the VS4I group. The σmax and σmin of bone are presented in Table 4. Similarly, the σmax and σmin were primarily concentrated in the cortical bone. The peak σmax and σmin were observed on distal implant-bone interface areas. In the cortical bone, the peak σmax value of the TL4I group was 35.72 MPa, which was similar to that of VS4I group (Fig. 4D-F). However, the peak σmin value of the TL4I group was 75.95 MPa, which was much higher compared to the VS4I group (Fig. 5D-F). As for the trabecular bone, similar stress levels were observed in both groups (Figs. 6D-F and 7D-F). In addition, the implants in the VS4I group exhibited slightly higher σVM values than that in the TL4I group (Fig. 8D-F).

Table 4 Summary of data obtained from TL4I and VS4I groups under vertical load on molars

Oblique load on incisors

When deliberating upon the oblique load on incisors, notable distinctions emerged between the TL4I and VS4I groups. The σmax and σmin primarily localized within the cortical bone surrounding the distal implants in the TL4I group, whereas in the VS4I group, they concentrated at the interface area between the mesial implant and bone. The σmax and σmin values of bone are showed in Table 5. In the cortical bone, the TL4I group exhibited a peak σmax value of 78.42 MPa, surpassing that of the VS4I group (Fig. 4G-I). The peak σmin value of TL4I groups was 80.36 MPa, closely resembling the VS4I group (Fig. 5G-I). Furthermore, comparable stress levels were observed in the trabecular bone (Figs. 6G-I and 7G-I). The σVM of the implants exhibited similarity between the two groups, with values of 104.51 MPa and 104.76 MPa, respectively (Fig. 8G-I).

Table 5 Summary of data obtained from TL4I and VS4I groups under vertical load on incisors

Discussions

In this FEA study, the CBCT was taken to construct the implantation models in a moderate atrophic maxilla. The objective was to compare the biomechanical behavior of two different treatment concepts - a fixed prosthesis supported by four implants in an edentulous and moderate atrophic maxilla [5]. While the application of fewer implants to support the prosthesis may result in cost reduction, the decrease of bone volume poses challenges for implant placement [26]. At present, the “all-on-4” treatment concept has been recognized for its success and practicality in scenarios where limited bone volume is present due to bone resorption and sinus pneumatization in the posterior region of the maxilla [27]. Furthermore, the utilization of short implants further serves as a feasible alternative with advantageous clinical results. Thus, it is necessary to conduct a biomechanical evaluation of the two treatment concepts.

Fellippo Ramos Verri et al. demonstrated that the application of simplified models for the implant surface can alter the distribution of stress and strain on the cortical bone [28]. Furthermore, a slight simplification of the implants, specifically the threads, has no impact on the distribution of stress and strain on the cortical bone tissue [28]. Therefore, a slight simplification of the implants was used in this study. To accurately simulate the oral clinical situation, abutments, central screws and prosthesis screws were established in this study. Furthermore, the anisotropic nature of both the cortical and trabecular bone, which cannot be disregarded in numerical simulations, was taken into consideration [14]. Moreover, various stress and strain measurements, such as von-Mises stress, maximum and minimum principal stress, and equivalent elastic strain, are commonly utilized for calculating and evaluating the biomechanical behaviors of both bones and implants. The maximum principal stress is usually used to observe tensile stress, while the minimum principal stress is used for compressive stress. This approach is fitting for examining the biomechanical behavior of bones due to their ductility and brittleness [5]. Titanium, as a ductile material, the von-Mises stress was selected for analysis. In addition, a convergence analysis is a crucial step in validating the reliability and accuracy of FEA results. However, convergence analysis may not be necessary for FEA, particularly when the following conditions are met: (1) Sufficiently refined mesh has been used to capture the key physical phenomena; (2) The obtained results are acceptable within the scientific accuracy and are consistent with existing analytical results. Therefore, convergence analysis was not performed in our study.

In all groups, the stress values of the cortical bone surpassed those of the trabecular bone. This phenomenon can be explained by the fact that cortical bones have a higher elastic modulus compared to trabecular bone. Thus, cortical bones exhibit greater strength and resilience against deformation. Consequently, cortical bones are subjected to elevated loads in clinical scenarios, distinguishing they from trabecular bones [29, 30]. Within this study, three types of loads were considered to simulate the oral mastication. Similar to previous studies, the oblique load models demonstrated higher levels of stress in comparison to the vertical load models [25, 31]. Furthermore, upon considering the oblique load on incisors, contrasting stress distributions were observed between the two groups. In the TL4I group, σmax and σmin were mainly concentrated on cortical bone around the distal implants, owing to the implant tilting. This result is in accordance with previous studies [5, 32].

In the realm of three different loading scenario, higher stresses were observed in the TL4I group compared to the VS4I group [30, 32]. When subjected to the oblique loading on molars, the TL4I group demonstrated a peak σmax value of 58.33 MPa, approximately 1.33 times greater than that of the VS4I group. Under vertical loading on molars, the TL4I group displayed a peak σmin value of 75.96 MPa, surpassing that of the VS4I group (43.48 MPa). Similarly, when subjected to an oblique load on incisors, the TL4I group exhibited a peak σmax value of 78.42 MPa, surpassing that of the VS4I group (52.33 MPa). This phenomenon can be attributed to the larger diameter of the short implants and the oblique of the long implants [16, 30]. Moreover, the uppermost portion of the implants, roughly 2-3 mm in length, plays a significant role in transferring the primary load to the surrounding bone tissue, aligning with the findings of other relevant studies [14, 15]. These findings may serve as a basis for selecting short implants assuming they are stably anchored in the bone. However, it is necessary to emphasize that the predictability of short implants is contingent upon various factors, such as implant design, placement protocol, remaining bone height and volume, occlusion conditions, and patient oral hygiene [1, 33].

Notably, surpassing the constraints of physiological limits (ultimate bone strength), when σmin reaches over 170 MPa or σmax exceeds 100 MPa, overloading of cortical bone may occur [1, 34]. In this study, the observed values in both treatment concepts were lower compared to those associated with histopathological bone. It can be concluded that both concepts are viable. These findings provide an explanation for the elevated success rate of the all-on-4 treatment method. It is imperative to ensure that the σVM value of the implants remains below 550 MPa, which corresponds to the yield strength of titanium implants. Failure to adhere to this threshold may result in implantation failure [35, 36]. Notably, none of the implants surpassing the σVM threshold of 550 MPa in this research.

There are still some limitations in this study. While the inclusion of static loads has been taken into account to represent occlusal loads, the existence of chewing movement necessitates the implementation of dynamic load simulations in future studies [5]. Moreover, it is noteworthy that the TL4I (all-on-4) treatment concept is typically applied to immediate loading rather than delayed loading in a clinical context [10]. However, in this study, the implants are fully osseointegrated, which means that the obtained results are more suitable for delayed loading. In conclusion, these findings provide us some clinical guidance, further longitudinal follow-up and randomized clinical trials are necessary to confirm the predictability of short implants.

Conclusion

Based on the findings of this study, both treatment concepts can be applied in edentulous and moderate atrophic maxilla. Compared to tilted implants, short implants can transmit less occlusal force to the supporting tissues. By optimizing the implant design and implantation procedure, short implants may be crucial to the restoration and rehabilitation of atrophic maxilla.

Data Availability

The data presented in this study are available on request from the corresponding author.

References

  1. Bhering CLB, Mesquita MF, Kemmoku DT, Noritomi PY, Consani RLX, Ricardo Barao VA. Comparison between all-on-four and all-on-six treatment concepts and framework material on stress distribution in atrophic maxilla: a prototyping guided 3D-FEA study. Mater Sci Eng C-Mater Biol Appl. 2016;69:715–25.

    Article  PubMed  Google Scholar 

  2. Lundgren S, Andersson S, Gualini F, Sennerby L. Bone reformation with sinus membrane elevation: a new surgical technique for maxillary sinus floor augmentation. Clin Implant Dent Relat Res. 2004;6(3):165–73.

    Article  PubMed  Google Scholar 

  3. Barone A, Ricci M, Covani U, Nannmark U, Azarmehr I, Calvo-Guirado JL. Maxillary sinus augmentation using Prehydrated Corticocancellous Porcine bone: hystomorphometric evaluation after 6 months. Clin Implant Dent Relat Res. 2012;14(3):373–9.

    Article  PubMed  Google Scholar 

  4. Bodic F, Hamel L, Lerouxel E, Basle MF, Chappard D. Bone loss and teeth. Joint Bone Spine. 2005;72(3):215–21.

    Article  PubMed  Google Scholar 

  5. Almeida EO, Rocha EP, Freitas AC, Anchieta RB, Poveda R, Gupta N, Coelho PG. Tilted and short implants supporting fixed prosthesis in an Atrophic Maxilla: a 3D-FEA biomechanical evaluation. Clin Implant Dent Relat Res. 2015;17:E332–42.

    Article  PubMed  Google Scholar 

  6. Esposito M, Barausse C, Pistilli R, Sammartino G, Grandi G, Felice P. Short implants versus bone augmentation for placing longer implants in atrophic maxillae: one-year post-loading results of a pilot randomised controlled trial. Eur J Oral Implant. 2015;8(3):257–68.

    Google Scholar 

  7. Thoma DS, Haas R, Sporniak-Tutak K, Garcia A, Taylor TD, Hammerle CHF. Randomized controlled multicentre study comparing short dental implants (6 mm) versus longer dental implants (11–15 mm) in combination with sinus floor elevation procedures: 5-Year data. J Clin Periodontol. 2018;45(12):1465–74.

    Article  PubMed  Google Scholar 

  8. Malo P, Rangert B, Nobre M. All-on-four immediate-function concept with Branemark System implants for completely edentulous mandibles: a retrospective clinical study. Clin Implant Dent Relat Res. 2003;5(Suppl 1):2–9.

    Article  PubMed  Google Scholar 

  9. Patzelt SBM, Bahat O, Reynolds MA, Strub JR. The All-on-Four Treatment Concept: a systematic review. Clin Implant Dent Relat Res. 2014;16(6):836–55.

    Article  PubMed  Google Scholar 

  10. Malo P, Lopes A, Nobre MD, Ferro A. Immediate function dental implants inserted with less than 30 N.cm of torque in full-arch maxillary rehabilitations using the All-on-4 concept: retrospective study. Int J Oral Maxillofac Surg. 2018;47(8):1079–85.

    Article  PubMed  Google Scholar 

  11. Fan TF, Li YC, Deng WW, Wu TF, Zhang WF. Short implants (5 to 8 mm) versus longer implants (> 8 mm) with sinus lifting in Atrophic Posterior Maxilla: a Meta-analysis of RCTs. Clin Implant Dent Relat Res. 2017;19(1):207–15.

    Article  PubMed  Google Scholar 

  12. Schincaglia GP, Thoma DS, Haas R, Tutak M, Garcia A, Taylor TD, Hammerle CHF. Randomized controlled multicenter study comparing short dental implants (6 mm) versus longer dental implants (11–15 mm) in combination with sinus floor elevation procedures. Part 2: clinical and radiographic outcomes at 1 year of loading. J Clin Periodontol. 2015;42(11):1042–51.

    Article  PubMed  Google Scholar 

  13. Bellini CM, Romeo D, Galbusera F, Taschieri S, Raimondi MT, Zampelis A, Francetti L. Comparison of Tilted Versus Nontilted Implant-supported prosthetic designs for the restoration of the Edentuous Mandible: a Biomechanical Study. Int J Oral Maxillofac Implants. 2009;24(3):511–7.

    PubMed  Google Scholar 

  14. Bonnet AS, Postaire M, Lipinski P. Biomechanical study of mandible bone supporting a four-implant retained bridge finite element analysis of the influence of bone anisotropy and foodstuff position. Med Eng Phys. 2009;31(7):806–15.

    Article  PubMed  Google Scholar 

  15. Bevilacqua M, Tealdo T, Menini M, Pera F, Mossolov A, Drago C, Pera P. The influence of cantilever length and implant inclination on stress distribution in maxillary implant-supported fixed dentures. J Prosthet Dent. 2011;105(1):5–13.

    Article  PubMed  Google Scholar 

  16. Takahashi T, Shimamura I, Sakurai K. Influence of number and inclination angle of implants on stress distribution in mandibular cortical bone with all-on-4 Concept. J Prosthodont Res. 2010;54(4):179–84.

    Article  PubMed  Google Scholar 

  17. Naini RB, Nokar S, Borghei H, Alikhasi M. Tilted or parallel Implant Placement in the completely edentulous Mandible? A three-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2011;26(4):776–81.

    PubMed  Google Scholar 

  18. Chiapasco M, Zaniboni M. Methods to treat the edentulous posterior Maxilla: implants with sinus grafting. J Oral Maxillofac Surg. 2009;67(4):867–71.

    Article  PubMed  Google Scholar 

  19. Kurniawan D, Nor FM, Lee HY, Lim JY. Finite element analysis of bone-implant biomechanics: refinement through featuring various osseointeg ration conditions. Int J Oral Maxillofac Surg. 2012;41(9):1090–6.

    Article  PubMed  Google Scholar 

  20. Silva GC, Mendonca JA, Lopes LR, Landre J. Stress patterns on implants in Prostheses supported by four or six implants: a three-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2010;25(2):239–46.

    PubMed  Google Scholar 

  21. Chen Y, Wang C, Huang YD, Feng TM, Zou HW, Fan YB. Biomechanical evaluation of the natural abutment teeth in combined tooth-implant-supported telescopic prostheses: a three-dimensional finite element analysis. Comput Methods Biomech Biomed Eng. 2017;20(9):967–79.

    Article  Google Scholar 

  22. Peixoto HE, Camati PR, Faot F, Sotto-Maior BS, Martinez EF, Peruzzo DC. Rehabilitation of the atrophic mandible with short implants in different positions: a finite elements study. Mater Sci Eng C-Materials Biol Appl. 2017;80:122–8.

    Article  Google Scholar 

  23. Kim JH, Kim JW, Myoung SW, Pines M, Zhang Y. Damage maps for layered ceramics under simulated mastication. J Dent Res. 2008;87(7):671–5.

    Article  PubMed  Google Scholar 

  24. Chen JY, Zhang ZG, Chen XS, Zhang X. Influence of custom-made implant designs on the biomechanical performance for the case of immediate post-extraction placement in the maxillary esthetic zone: a finite element analysis. Comput Methods Biomech Biomed Eng. 2017;20(6):636–44.

    Article  Google Scholar 

  25. Cinel S, Celik E, Sagirkaya E, Sahin O. Experimental evaluation of stress distribution with narrow diameter implants: a finite element analysis. J Prosthet Dent. 2018;119(3):417–25.

    Article  PubMed  Google Scholar 

  26. Testori T, Del Fabbro M, Capelli M, Zuffetti F, Francetti L, Weinstein RL. Immediate occlusal loading and tilted implants for the rehabilitation of the atrophic edentulous maxilla: 1-year interim results of a multicenter prospective study. Clin Oral Implant Res. 2008;19(3):227–32.

    Article  Google Scholar 

  27. Hopp M, Nobre MD, Malo P. Comparison of marginal bone loss and implant success between axial and tilted implants in maxillary all-on-4 treatment concept rehabilitations after 5 years of follow-up. Clin Implant Dent Relat Res. 2017;19(5):849–59.

    Article  PubMed  Google Scholar 

  28. Verri FR, Cruz RS, Batista VED, Almeida DAD, Verri ACG, Lemos CAD, Santiago JF, Pellizzer EP. Can the modeling for simplification of a dental implant surface affect the accuracy of 3D finite element analysis? Comput Methods Biomech Biomed Eng. 2016;19(15):1665–72.

    Article  Google Scholar 

  29. Schuller-Gotzburg P, Entacher K, Petutschnigg A, Pomwenger W, Watzinger F. Sinus elevation with a cortical bone graft block: a patient-specific three-dimensional finite element study. Int J Oral Maxillofac Implants. 2012;27(2):359–68.

    PubMed  Google Scholar 

  30. Seker E, Ulusoy M, Ozan O, Dogan DO, Seker BK. Biomechanical effects of different fixed partial denture designs planned on Bicortically Anchored Short, graft-supported Long, or 45-Degree-inclined long implants in the posterior Maxilla: A three-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2014;29(1):E1–E9.

    Article  PubMed  Google Scholar 

  31. Wu D, Tian KB, Chen J, Jin H, Huang WX, Liu YY. A Further Finite Element Stress Analysis of Angled Abutments for an Implant Placed in the Anterior Maxilla. Comput Math Method Med 2015, 2015:9.

  32. Dogan DO, Polat NT, Polat S, Seker E, Gul EB. Evaluation of all-on-four Concept and Alternative designs with 3D finite element analysis Method. Clin Implant Dent Relat Res. 2014;16(4):501–10.

    Article  Google Scholar 

  33. Corbella S, Taschieri S, Del Fabbro M. Long-term outcomes for the Treatment of Atrophic Posterior Maxilla: a systematic review of literature. Clin Implant Dent Relat Res. 2015;17(1):120–32.

    Article  PubMed  Google Scholar 

  34. Liu T, Mu ZX, Yu T, Wang C, Huang YD. Biomechanical comparison of implant inclinations and load times with the all-on-4 treatment concept: a three-dimensional finite element analysis. Comput Methods Biomech Biomed Eng. 2019;22(6):585–94.

    Article  Google Scholar 

  35. Akca K, Iplikcioglu H. Finite element stress analysis of the effect of short implant usage in place of cantilever extensions in mandibular posterior edentulism. J Oral Rehabil. 2002;29(4):350–6.

    Article  PubMed  Google Scholar 

  36. Kaleli N, Sarac D, Kulunk S, Ozturk O. Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: a three-dimensional finite element analysis study. J Prosthet Dent. 2018;119(3):437–45.

    Article  PubMed  Google Scholar 

  37. O’Mahony AM, Williams JL, Spencer P. Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increases peri-implant stress and strain under oblique loading. Clin Oral Implants Res. 2001;12(6):648–57.

    Article  PubMed  Google Scholar 

  38. Lewinstein I, Banks-Sills L, Eliasi R. Finite element analysis of a new system (IL) for supporting an implant-retained cantilever prosthesis. Int J Oral Maxillofac Implants. 1995 May-Jun;10(3):355–66.

  39. Fuh LJ, Hsu JT, Huang HL, Chen MY, Shen YW. Biomechanical investigation of thread designs and interface conditions of zirconia and titanium dental implants with bone: three-dimensional numeric analysis. Int J Oral Maxillofac Implants. 2013 Mar-Apr;28(2):e64–71.

Download references

Acknowledgements

Not applicable.

Funding

This study was supported by Zhejiang Provincial Science and Technology Project for Public Welfare (Grant No. LGF22H140010); the Science and Technology Plan of Wenzhou (Grant No. H20210008).

Author information

Authors and Affiliations

Authors

Contributions

A. Li and Z. Mu constructed 3D models; B. Zeng and T. Shen performed finite element analysis; A. Li and Z. Mu wrote the main manuscript text; R. Hu and A. Li conducted experimental design; H. Wang and H. Deng reviewed and revised the first draft; All authors reviewed the manuscript.

Corresponding authors

Correspondence to Huining Wang or Hui Deng.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Li, A., Mu, Z., Zeng, B. et al. Evaluation of two treatment concepts of four implants supporting fixed prosthesis in an atrophic maxilla: finite element analysis. BMC Oral Health 23, 983 (2023). https://doi.org/10.1186/s12903-023-03706-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12903-023-03706-4

Keywords