Skip to main content

Comparative biomechanics of all-on-4 and vertical implant placement in asymmetrical mandibular: a finite element study

Abstract

Background

Clinical scenarios frequently present challenges when patients exhibit asymmetrical mandibular atrophy. The dilemma arises: should we adhere to the conventional All-on-4 technique, or should we contemplate placing vertically oriented implants on the side with sufficient bone mass? This study aims to employ three-dimensional finite element analysis to simulate and explore the biomechanical advantages of each approach.

Methods

A finite element model, derived from computed tomography (CT) data, was utilized to simulate the nonhomogeneous features of the mandible. Three configurations—All-on-4, All-on-5-v and All-on-5-o were studied. Vertical and oblique forces of 200 N were applied unilaterally, and vertical force of 100 N was applied anteriorly to simulate different masticatory mechanisms. The maximum von Mises stresses on the implant and framework were recorded, as well as the maximum equivalent strain in the peri-implant bone.

Results

The maximum stress values for all designs were located at the neck of the distal implant, and the maximum strains in the bone tissue were located around the distal implant. The All-on-5-o and All-on-5-v models exhibited reduced stresses and strains compared to All-on-4, highlighting the potential benefits of the additional implant. There were no considerable differences in stresses and strains between the All-on-5-o and All-on-5-v groups.

Conclusions

With the presence of adequate bone volume on one side and severe atrophy of the contralateral bone, while the “All-on-4 concept” is a viable approach, vertical implant placement optimizes the transfer of forces between components and tissues.

Peer Review reports

Introduction

The success of the All-on-4 technique has been widely established [1,2,3,4], particularly for cases involving severe atrophy of the mandibular bone, where there is insufficient vertical bone height in the posterior region. However, clinical scenarios frequently present themselves with patients exhibiting significant atrophy on one side of the mandible, while the other side possesses adequate alveolar bone height for implant placement. In such cases, a crucial decision arises: should the traditional All-on-4 technique be employed, or is it more advantageous to opt for conventional vertical implant placement on the side with sufficient bone volume?

The cantilever is currently considered to be the main factor influencing the success of implant-supported fixed prosthetic restorations, and it is widely recognized that the length of the cantilever of the upper restoration has a positive effect on the reduction of stress in the peri-implant bone [5]. Due to anatomical limitations, the classic All-on-4 may still produce a cantilever that increases the probability of mechanical complications in the restoration such as loosening of the abutment and screw and fracture of the upper bracket; moreover, the bending moment caused by the load applied to the cantilever can increase the force on the implant by 2-3 times, which is directly related to overloading of the peri-implant bone tissue [6, 7].

For patients with edentulous jaws, the alveolar bone heights on both sides of the jaw are often inconsistent. In clinical practice, such patients are often encountered: the absorption degree of the posterior dental area on both sides of the mandible is different, and the vertical bone volume of the posterior dental area on one side is sufficient, while the bone volume of the other side is insufficient, whether to choose the traditional All-on-4 technique or the option of adding vertical implant placement at the end of the cantilever on the side with sufficient bone is a dilemma that most implantologists will encounter in these cases. There have been no studies on the finite element aspects of performing 5-implant-supported fixed restorations in mandibular edentulous jaws with insufficient bone in the unilateral posterior region. And to date, the extent of the difference in load between vertically placed and angled implants in the case of distal bone abundance has been unclear [8,9,10].

This study compared the biomechanical aspects of vertical implant placement technique on the side with sufficient bone volume with the standard All-on-4 treatment concept by evaluating the stresses on the implants, and prosthetic components and strains in peri-implant bone in unilateral models of severely atrophied mandible treated with these techniques.

Materials and methods

A finite element model of the edentulous mandible was constructed from computed tomography (CT) data, and 4 or 5 implants were placed in the mandible. Occlusal loading was simulated in the models to analyze the biomechanical behavior of the components and bone tissue.

Design of the components

In this study, a spiral CT scanner (Siemens, SOMATOM Definition AS128, Germany) was used to obtain CT data of the mandible of a 68-year-old healthy male volunteer. The scanning parameters were set to a voltage of 120 kV, a maximum tube current of 666 mA, and a layer thickness of 0.6 mm.The study protocol was approved by the Ethics Committee of Hospital (QT2023427), and written informed consent was obtained in advance. The CT data were imported in Digital Imaging and Communications in Medicine (DICOM) format into Mimics software (V19.0; Materialise), and a rough 3D contour of the mandible was obtained through thresholds and masks and exported as an Stereolithography (STL) file. The 3D solid model of the mandible showed different degrees of alveolar bone resorption in the posterior region bilaterally, with severe resorption of the alveolar bone behind the mental foramen on the right side, and adequate height and width of the alveolar ridge on the left side (Fig. 1a). Model of the dentition was obtained by scanning the denture in the patient’s mouth with a Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) oral scanning machine (3 shape TRIOS), then exocad-Dental CAD (3.1 Rijeka) was used to trim and export to STL file.

Fig. 1
figure 1

(a) 4-implant-supported model. The mandibular model reconstructed by CT showed varying degrees of bilateral atrophy of the alveolar bone, (b) Morphology and structure of implants, abutments and screws

The models were imported into Geomagic Studio software (V13; Geomagic) for refinement, and the irregular burrs on its surface as well as the small unconnected areas inside were processed while not altering the morphology of the actual mandible and superstructure, to obtain complete and accurate 3D solid models in preparation for the next step of mesh delineation smoothly, and then exported in STL format. Finally, prosthesis and titanium framework models were obtained by extraction of the dentition, and the prosthesis was restored to the occlusal surface of the bilateral first molars (Fig. 2).

Fig. 2
figure 2

Three model designs. The cantilever length shown on the All-on-4 model was 15 mm

The implants in the model refer to the Nobel active system, and the implants were divided into three types according to length and position: the anterior dental implants were 3.5 mm × 11.5 mm, vertical implants in the posterior dental area were 4.3 mm × 11.5 mm, and oblique implants were 4.3 mm × 13 mm. Two abutment designs were employed, including a straight abutment with a height of 3.5 mm and an angle of 0°, and a 30° angled abutment with a height of 4.5 mm. Models were designed in SolidWorks (V2014; Dassault Systemes) based on the implant shape data, abutments, and screws (Fig. 1b).

Grouping of models

Three groups were established: All-on-4, All-on-5-o, All-on-5-v (Fig. 2). The dental positions were numbered from the right to the left side of the mandible: 45, 42, 32, 35, 36, with 4 represents the right region, 3 represents the left region (Fig. 2). The All-on-4 group placed the terminal implants in positions 35 and 45 so that the cantilever length was set to 15 mm [11], and All-on-5-o and All-on-5-v groups added an implant at position 36 eliminating the left cantilever (Fig. 2).

Meshing and metrics

Each set of models underwent importation into 3-matic software (V11.0) for the generation of tetrahedral elements. Prior to division, a specified mesh size was established: the mesh of the implant-bone contact surface and the contact surfaces of the abutment and framework underwent partial refinement, with the mesh size set to 0.2 mm, taking into consideration the mesh accuracy and the convergence speed of subsequent calculations.

The number of elements and nodes used by each model are shown in Table 1. The Abaqus software (V6.14; Dassault Systemes) was utilized to calculate von Mises stresses and equivalent strains. After convergence analysis, the error margin was less than 1%. Maximum von Mises stresses were recorded on implants and frameworks to describe the material deformation stress state [12]. Equivalent strains of peri-implant bone can be used to predict the bone remodeling nature as compared to bone resorption threshold limits [13,14,15,16,17]. Subsequently, the data were systematically gathered and color-coded for the purpose of comparative evaluation.

Table 1 Elements and nodes for each model

Material properties

A three-dimensional model of the mandible with non-uniform material properties corresponding to the bone properties of different anatomical sites was established to improve the accuracy of the finite element models. The material properties of bone was determined from different radiodensity values of CT images [18]. The material properties (bone density and elastic modulus) of Hounsfield unit (HU) based model of the CT image were defined using Mimics software (V19.0, Materialise, Leuven, Belgium. The correlation between HU and bone density (ρ0) was derived from Eq. (1) [18].

$$\rho_{0}{\rm{ }} = 47 + {\rm{ }}1.122{\rm{ }} \times HU\left[ {kg/{m^3}} \right]$$
(1)

The elastic modulus (E) is related to the bone density (ρ0) as described in Eq. (2).

$$E = 0.63 \times \rho_{0}{^{1.35}}\left[ {MPa} \right]$$
(2)

Figure 3a shows the color-coded mass density mapping of our model. Figure 3b shows the corresponding colors and mass densities and elastic moduli which were derived from Eqs. (1) and (2). The Poisson’s ratio was set as 0.35. Combined with Fig. 3a and b, it can be seen that the density of the mandible ranges from 107 to 1889 kg/m3, the elastic modulus ranges from 349 to 16,686 MPa, and the Poisson ratio is 0.3. The cortical bone is mainly yellow and orange, that is, the elastic modulus is between 12 and 17 GPa. Cancellous bone is mainly cyan and blue, that is, the elastic modulus is small. In addition, the mandible surface showed some cyan images, which is likely due to Mimics’ failure to accurately separate the mandible from soft tissue residues such as periosteum. After material attribute assignment, the mandibular tetrahedral mesh model was saved and exported in INP format. It can be seen from the results that the material properties assigned to the mandible are within a reasonable range [19], which verifies the rationality and validity of the derived linear equation between the apparent bone density and the HU scale and the logarithmic equation between the elastic modulus and the apparent bone density for constructing the material properties of the mandible.

The elastic modulus of acrylic and titanium is 3000 MPa and 112 GPa respectively, both parts made of pure titanium and prosthesis made of acrylic material have the Poisson’s ratio of 0.35 [20].

Fig. 3
figure 3

(a) Sagittal cross-sectional image of inhomogeneous mandible with different bone density mappings, (b) Material properties generation Interface

Constraints and loading conditions

To accurately simulate anatomically normal mandibular function, the bilateral condyles were assumed to be locked in the articular fossa and constrained to full degrees of freedom [21,22,23]. Materials were modeled with small deformations and linear elastic behavior. The implant-bone interface was configured as 100% contact, incorporating rigid restraints to prevent any relative sliding during application. Following the “All-on-4” concept, the average force applied to the premolar and molar regions in fixed prostheses approximated 200–300 N, and for incisors, it ranged from 100 to 300 N [24]. To simulate the clinical masticatory forces, each model used three loading patterns: (1) Vertical load in anterior teeth area (Load AV): 100 N vertical load in the incisors region (Fig. 4a); (2) Vertical load in posterior teeth area (Load PV): 200 N vertical load in the left posterior teeth region (Fig. 4b); (3) Oblique load in posterior teeth area (Load PO): 200 N oblique load in the left posterior teeth region with a 45°lingual-buccal tilt (Fig. 4c).

Fig. 4
figure 4

(a) Simulated vertical occlusal load of 100 N in the incisal region, (b) Simulated vertical occlusal load of 200 N in the left posterior region, (c) Simulated oblique occlusal load of 200 N in the left posterior region

Results

Max von Mises stresses on the Dental Implants

Figure 5 shows the stresses distribution at the implant level under three different models. The stresses in all groups of implants were concentrated in the cervical region under the three loading patterns (Fig. 5). When force was applied to the anterior region, bilateral implants experience a uniform force, while applying force to the posterior region results in a larger red area (indicating high stress) for the last two implants near the loaded, with each implant experiencing an uneven force. The area of stress concentration on the implant at position 35 was largest in the All-on-4 model compared to the All-on-5 models for all three loads (Fig. 5). The maximum von Mises stresses were observed at the neck of the 35 implant in the All-on-4 model under load PV (215.0 MPa) and load PO (447.7 MPa) (Table 2). The maximum stresses on this implant were reduced by 38.6% in All-on-5-o and 35.2% in All-on-5-v compared to All-on-4 under load PV, with reductions of 41.1% and 46.3%, respectively, under load PO (Table 2). When force was applied in the anterior region, the maximum stresses were detected on the 45 implant compared to when force was applied in the posterior region, and similar maximum stress values were found across all three groups (Table 2).

As can be seen in Table 2, the stresses on the implant were related to the direction of loading, with the value of stresses under inclined loading being approximately twice as high as under vertical loading. In addition, the All-on-5-o group had similar stress levels to the All-on-5-v group.

Fig. 5
figure 5

Distribution of von Mises stresses on implants under three different loads

Table 2 The Maximum von Mises stress values in implants (MPa)

Max von Mises stresses on the Frameworks

The stress distribution on the framework showed a consistent trend in all three models, with higher stresses in the areas near the location of the applied force and lower stresses in the areas away from the applied force (Fig. 6). When the load was located in the posterior region, the red area detected in the All-on-4 group when subjected to a 45° angled load was the largest, whereas the other two groups were both reduced compared to the All-on-4 group (Fig. 6).

The stress values on the framework of the All-on-5-o model presented the lowest results when the force was applied in the posterior region (Table 3). However, the maximum von Mises stress values on the framework when the applied force was in anterior teeth were lowest in All-on-4 group (Table 3). The maximum von Mises stress values found on the frameworks under oblique loading were higher than vertical loading, about three to four times (Table 3).

Fig. 6
figure 6

Distribution of von Mises stresses on framework under three different loads

Table 3 The Maximum von Mises stress values in framework (MPa)

Equivalent strains in the peri-implant Bone

Figure 7; Table 4 summarize the maximum equivalent strains of the peri-implant bone for the three designs under the three loads. Higher strains were observed in all groups of models at the top of the alveolar ridge in the bilateral posterior region of the mandible under the anterior region load, while higher strains were observed in the buccal side of the left posterior region of the mandible as well as in the lingual side of the right posterior region of the mandible in all three models when the load was located in the posterior region (Fig. 7).

In comparison with the All-on-4 model, the peri-implant bone in the remaining two groups at position 35 showed reduced and more dispersed areas of strain (Fig. 7). Regardless of the load, the maximum strain values of each model bone were detected on the terminal implant, with the maximum equivalent strain of the bone tissue of the All-on-4 model being located on the bone around the peri-distal of the 35 implant, which was 0.76 × 103 µε (load AV), 4.20 × 103 µε (load PV), and 4.51 × 103 µε (load PO) (Table 4), whereas placing the vertical implant placed at the left end of the two models, although the increased peri-implant strains around the vertical implant was greater, the maximum equivalent strain values of the peri-implant bone located at position 35 were reduced by 36.8% (All-on-5-o) and 73.7% (All-on-5-v), respectively, in comparison to the All-on-4 group under load AV, 75.7% (All-on-5-o) and 91.2% (All-on-5-v) reduction under load PV, and 74.1% (All-on-5-o) and 83.4% (All-on-5-v) reduction under load PO, respectively (Table 4).

The strains in the same designed model were greater under oblique loading as compared to vertical loading. In addition, the difference in strains on bone tissue between the All-on-5-o design and the All-on-5-v design was less (Fig. 7; Table 4).

Fig. 7
figure 7

Equivalent strain distributions for three models under different loads

Table 4 The Maximum equivalent strain values (103µε) of bone around implants

Discussion

Previous findings affirm the well-documented success of the All-on-4 technique in cases of severe mandibular atrophy [1,2,3,4, 25, 26]. However, when faced with patients exhibiting unilateral atrophy and sufficient bone volume on the opposing side, our simulations suggest that conventional vertical implant placement may offer distinct biomechanical advantages. The three-dimensional finite element analysis provided insights into stress distribution patterns around implants and the surrounding tissues, aiding in the evaluation of the mechanical efficacy of each treatment modality. The decision between the traditional All-on-4 technique and vertical implant placement on the side with ample bone volume should be made on a case-by-case basis, considering the individual anatomical and clinical factors.

For the “All-on-4” operation on the mandible with edentulous mandible, whether the inclined implant at the end will be overloaded at the stress concentration site is a problem that we need to consider, and the influence of the stress on the surrounding bone tissue is also controversial. Some scholars [27, 28] believed that the cantilever design would increase the stress of the bone tissue around the distal implant, resulting in occlusal overload. Relatively speaking, the non-cantilever design of implant-supported fixation could better disperse the stress of the implant and the surrounding bone tissue [29, 30]. In this study, a case with severe unilateral mandibular alveolar bone atrophy was selected to extract the model, the advantage of this approach is that it accurately reflects the characteristics of the current clinical case. The differences in the biomechanical rows of the vertical implant placed at the cantilever on the side with sufficient bone were compared with the All-on-4 technique to provide biomechanical insights for making the most rational decisions when encountering such cases in the clinic.

The success of Three-dimensional finite element analysis (3D FEA) techniques has been reported to be related to the proportion of elements and nodes in the prepared mathematical model [31]. In this study, the All-on-4 model contained a total of 301,847 nodes and 2,272,953 elements, which is a sufficient number of nodes and elements to maximize the sensitivity of the analysis compared to similar studies [32, 33].

Compared to the All-on-4 technique, vertical implant placement with the lowest stresses and strains under three different forces represented the best-case condition in this study. The analysis results of all models showed that the maximum von Mises stresses of the implants were mainly concentrated in the neck of the distal implant on the loading side, which were consistent with the results of Sarrafpour [34] and Mahony et al [35]. Under different loads, the stress values of the implants and framework in both three models were lower than the yield strength of titanium (960  1180MPa) [36]. In addition, the maximum stress values on the implants in all models were observed on the most distal implant in the All-on-4 group, whereas the All-on-5-o versus All-on-5-v models avoided the concentration of stress in the neck of the implant at position 35 due to the addition of the vertical implant placement, which may be attributed to the elimination of one side of the cantilever by the placement of the vertical implant, minimizing the negative biomechanical benefits.

Several studies have shown that long-term bone remodeling or bone resorption is a process of adaptation of biological systems to a mechanical state [37, 38]. The maximum strain values of the bone around the neck of the left distal-most implant were higher than the bone resorption threshold reported by Sugiura et al [14] (equivalent strain value of 3.6 × 103µε)when subjected to a unilateral vertical or oblique force of 200 N by the conventional All-on-4 technique, and the maximum strains in the peri-implant bone at position 35 in the All-on-5-o and All-on-5-v groups were less than this value (Table 4). This shows that vertical implant placement technology can effectively reduce the risk of bone tissue absorption and better for long-term bone remodeling. It can be concluded that one-piece unilateral non-cantilevered restorations supported by a sufficient number of implants can optimize the transfer of force between different structures and tissues when there is sufficient bone volume on one side of the mandible.

In implant-supported fixed prosthetics, the clinical placement of implants was basically symmetrically distributed, and the technique of vertical implant placement proposed in this experiment resulted in an asymmetric distribution of implants in the mandible, which, according to the results, led to a more balanced distribution of stresses on all implants and strains on the surrounding bone tissues with no concentration of stresses on a single site. However, since there are fewer clinical efficacy studies related to the effect of symmetry on fixed restorations in edentulous jaws, more clinical studies should be conducted for further corroboration.

Some studies have found that the stresses under oblique load are significantly higher than that under vertical load, even up to 3.5 times [39]. The oblique load of 200 N was used in this study, and the stresses detected on each structure were significantly higher than the vertical load of 200 N. Therefore, the direction of the additional force also has a certain influence on the generation of stresses. The lateral force generated in the oblique load will form a lateral lever, and the resulting stresses are more likely to lead to the occurrence of related mechanical complications.

It is worth noting that an implant length of 11.5 mm was chosen for this study, mainly due to the sufficient bone volume on the left side of this mandibular model, and a longer implant would provide a larger implant-bone contact area, thus improving the implant’s stability. However, in practice, this may present some challenges, such as the need for more supportive bone volume and the possibility of compromising important anatomical structures. Therefore, although an 11.5 mm implant was selected, it may not be suitable for all clinical situations. In addition, in order to make the models more realistic and to improve the accuracy of the results, we set up the inhomogeneity of the jaw. However, in order to simplify the models and improve computational efficiency, this study simplified the partial design of the finite element model and set more idealized tissue and structural properties, such as neglecting the influence of the masticatory muscles, constraining the motion of the bilateral condyles and rostral processes, indeed, the mandible is surrounded by strong masticatory muscles attached to it, including the occlusal, temporal, intrapterygoid, and extrapterygoid muscles, which may have an impact on the biomechanical behavior of the mandible; Assuming that the mandible is linearly elastic and isotropic, in fact, the mandible has certain viscoelasticity and anisotropy [40]; As in other studies [41, 42] it was assumed that the implants were 100% osseointegrated with the bone. Although histologic studies have shown that osseointegration between the bone-implant interface has not been entirely materialized [43]. Our study was based on CT data of a patient with typical bone morphology characteristics. Therefore, the results of this study can only be used as a reference for patients with similar mandibular morphology. Also, in order to further confirm its validity and applicability, our results need to be validated in a larger group of patients.

Our study contributes valuable biomechanical insights to guide clinicians in making informed decisions tailored to the specific needs of patients facing such challenging scenarios. Future research and clinical trials are warranted to validate these simulated findings and further enhance our understanding of optimal treatment strategies for individuals with varying mandibular bone conditions.

Conclusion

According to the findings of this study, unlike the conventional All-on-4 technique, the usage of vertical implant placement resulted in a reduction of stresses and strains on the implant and bone tissues in cases of adequate bone volume in the unilateral mandibular molar region and severe atrophy of the contralateral bone volume. Therefore, within the limitations of this study, it is believed that vertical implant placement could assume a more pivotal role in the rehabilitation of unilateral severely atrophic mandibles by optimizing the implant protocol design.

Data availability

All data are calculated by the software itself. The datasets used and/or analysed during the current study available from the corresponding author on reasonable request.

Abbreviations

CT:

Computed Tomography

DICOM:

Digital Imaging and Communications in Medicine

STL:

Stereolithography

CAD/CAM:

Computer Aided Design/Computer Aided Manufacturing

3D FEA:

Three-dimensional finite element analysis

References

  1. Maló P, Rangert B, Nobre M. All-on-four immediate-function concept with Brånemark System implants for completely edentulous mandibles: a retrospective clinical study. Clin Implant Dent Relat Res. 2003;5(Suppl 1):2–9.

    Article  PubMed  Google Scholar 

  2. Agliardi E, Panigatti S, Clericò M, Villa C, Malò P. Immediate rehabilitation of the edentulous jaws with full fixed prostheses supported by four implants: interim results of a single cohort prospective study. Clin Oral Implants Res. 2010;21(5):459–65.

    Article  PubMed  Google Scholar 

  3. Maló P, Nobre Mde A, Petersson U, Wigren S. A pilot study of complete edentulous rehabilitation with immediate function using a new implant design: case series. Clin Implant Dent Relat Res. 2006;8(4):223–32.

    Article  PubMed  Google Scholar 

  4. Maló P, de Araújo Nobre M, Rangert B. Short implants placed one-stage in maxillae and mandibles: a retrospective clinical study with 1 to 9 years of follow-up. Clin Implant Dent Relat Res. 2007;9(1):15–21.

    Article  PubMed  Google Scholar 

  5. Sertgöz A, Güvener S. Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant-supported fixed prosthesis. J Prosthet Dent. 1996;76(2):165–9.

    Article  PubMed  Google Scholar 

  6. McAlarney ME, Stavropoulos DN. Determination of cantilever length-anterior-posterior spread ratio assuming failure criteria to be the compromise of the prosthesis retaining screw-prosthesis joint. Int J Oral Maxillofac Implants. 1996;11(3):331–9.

    CAS  PubMed  Google Scholar 

  7. Drago C, Howell K. Concepts for designing and fabricating metal implant frameworks for hybrid implant prostheses. J Prosthodontics: Official J Am Coll Prosthodontists. 2012;21(5):413–24.

    Article  Google Scholar 

  8. Tabrizi R, Pourdanesh F, Zare S, Daneste H, Zeini N. Do angulated implants increase the amount of bone loss around implants in the anterior maxilla? J oral Maxillofacial Surgery: Official J Am Association Oral Maxillofacial Surg. 2013;71(2):272–7.

    Article  Google Scholar 

  9. Sannino G, Bollero P, Barlattani A, Gherlone E. A retrospective 2-Year clinical study of Immediate Prosthetic Rehabilitation of Edentulous Jaws with four implants and prefabricated bars. J Prosthodontics: Official J Am Coll Prosthodontists. 2017;26(5):387–94.

    Article  Google Scholar 

  10. Gherlone EF, Sannino G, Rapanelli A, Crespi R, Gastaldi G, Capparé P. Prefabricated Bar System for Immediate Loading in Edentulous Patients: A 5-Year Follow-Up Prospective Longitudinal Study. BioMed research international 2018, 2018:7352125.

  11. Shackleton JL, Carr L, Slabbert JC, Becker PJ. Survival of fixed implant-supported prostheses related to cantilever lengths. J Prosthet Dent. 1994;71(1):23–6.

    Article  CAS  PubMed  Google Scholar 

  12. Mellal A, Wiskott HW, Botsis J, Scherrer SS, Belser UC. Stimulating effect of implant loading on surrounding bone. Comparison of three numerical models and validation by in vivo data. Clin Oral Implants Res. 2004;15(2):239–48.

    Article  CAS  PubMed  Google Scholar 

  13. Melsen B, Lang NP. Biological reactions of alveolar bone to orthodontic loading of oral implants. Clin Oral Implants Res. 2001;12(2):144–52.

    Article  CAS  PubMed  Google Scholar 

  14. Sugiura T, Horiuchi K, Sugimura M, Tsutsumi S. Evaluation of threshold stress for bone resorption around screws based on in vivo strain measurement of miniplate. J Musculoskel Neuronal Interact. 2000;1(2):165–70.

    CAS  Google Scholar 

  15. Frost HM. Perspectives: bone’s mechanical usage windows. Bone Min. 1992;19(3):257–71.

    Article  CAS  Google Scholar 

  16. Frost HM. A 2003 update of bone physiology and Wolff’s Law for clinicians. Angle Orthod. 2004;74(1):3–15.

    PubMed  Google Scholar 

  17. Frost HM. From Wolff’s law to the Utah paradigm: insights about bone physiology and its clinical applications. Anat Rec. 2001;262(4):398–419.

    Article  CAS  PubMed  Google Scholar 

  18. Rho JY, Hobatho MC, Ashman RB. Relations of mechanical properties to density and CT numbers in human bone. Med Eng Phys. 1995;17(5):347–55.

    Article  CAS  PubMed  Google Scholar 

  19. Huiskes R. Validation of adaptive bone-remodeling simulation models. Stud Health Technol Inform. 1997;40:33–48.

    CAS  PubMed  Google Scholar 

  20. Ozan O, Kurtulmus-Yilmaz S. Biomechanical comparison of different Implant inclinations and Cantilever lengths in all-on-4 treatment Concept by three-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2018;33(1):64–71.

    Article  PubMed  Google Scholar 

  21. Cheng KJ, Liu YF, Wang R, Zhang JX, Jiang XF, Dong XT, Xu X. Topological optimization of 3D printed bone analog with PEKK for surgical mandibular reconstruction. J Mech Behav Biomed Mater. 2020;107:103758.

    Article  CAS  PubMed  Google Scholar 

  22. Orassi V, Duda GN, Heiland M, Fischer H, Rendenbach C, Checa S. Biomechanical Assessment of the validity of Sheep as a preclinical model for testing mandibular fracture fixation devices. Front Bioeng Biotechnol. 2021;9:672176.

    Article  PubMed  PubMed Central  Google Scholar 

  23. Orassi V, Fischer H, Duda GN, Heiland M, Checa S, Rendenbach C. In Silico Biomechanical evaluation of WE43 magnesium plates for mandibular fracture fixation. Front Bioeng Biotechnol. 2021;9:803103.

    Article  PubMed  Google Scholar 

  24. Guven N, Topuz O, Yikilgan İ. Evaluation of Different Restoration Combinations Used in the Reattachment of Fractured Teeth: A Finite Element Analysis. Appl Bionics Biomech 2018, 2018:8916928.

  25. Reissmann DR, Dard M, Lamprecht R, Struppek J, Heydecke G. Oral health-related quality of life in subjects with implant-supported prostheses: a systematic review. J Dent. 2017;65:22–40.

    Article  PubMed  Google Scholar 

  26. MA EL, Elgamal M, Mohammed Askar O, Youssef Al-Tonbary G. Patient satisfaction and oral health-related quality of life (OHRQoL) of conventional denture, fixed prosthesis and milled bar overdenture for all-on-4 implant rehabilitation. A crossover study. Clin Oral Implants Res. 2019;30(11):1107–17.

    Article  Google Scholar 

  27. Al-Omiri MK, Al-Masri M, Alhijawi MM, Lynch E. Combined Implant and tooth support: an Up-to-date Comprehensive Overview. Int J Dent. 2017;2017:1687–8728. (Print)):6024565.

    Article  Google Scholar 

  28. Cenkoglu BG, Balcioglu NB, Ozdemir T, Mijiritsky E. The Effect of the length and distribution of implants for fixed prosthetic reconstructions in the Atrophic Posterior Maxilla: a finite element analysis. Mater (Basel Switzerland) 2019, 12(16).

  29. Horita S, Sugiura T, Yamamoto K, Murakami K, Imai Y, Kirita T. Biomechanical analysis of immediately loaded implants according to the All-on-four concept. J Prosthodontic Res. 2017;61(2):123–32.

    Article  Google Scholar 

  30. Sugiura T, Yamamoto K, Horita S, Murakami K, Kirita T. Micromotion analysis of different implant configuration, bone density, and crestal cortical bone thickness in immediately loaded mandibular full-arch implant restorations: a nonlinear finite element study. Clin Implant Dent Relat Res. 2018;20(1):43–9.

    Article  PubMed  Google Scholar 

  31. DeTolla DH, Andreana S, Patra A, Buhite R, Comella B. Role of the finite element model in dental implants. J Oral Implantol. 2000;26(2):77–81.

    Article  CAS  PubMed  Google Scholar 

  32. Fanuscu MI, Vu HV, Poncelet B. Implant biomechanics in grafted sinus: a finite element analysis. J Oral Implantol. 2004;30(2):59–68.

    Article  PubMed  Google Scholar 

  33. Koca OL, Eskitascioglu G, Usumez A. Three-dimensional finite-element analysis of functional stresses in different bone locations produced by implants placed in the maxillary posterior region of the sinus floor. J Prosthet Dent. 2005;93(1):38–44.

    Article  PubMed  Google Scholar 

  34. Isidor F. Influence of forces on peri-implant bone. Clin Oral Implants Res 2006, 17 Suppl 2(1600 – 0501 (Electronic)):8–18.

  35. Eltaftazani IMA, El-Anwar M. 2010.

  36. Mechanical Properties of Ti–6Al–4V Titanium Alloy with Submicrocrystalline Structure Produced by Severe Plastic Deformation. Materials Transactions 2005, 46(9):2020–2025.

  37. Sato E, Shigemitsu R, Mito T, Yoda N, Rasmussen J, Sasaki K. The effects of bone remodeling on biomechanical behavior in a patient with an implant-supported overdenture. Comput Biol Med. 2021;129:104173.

    Article  CAS  PubMed  Google Scholar 

  38. Shigemitsu R, Yoda N, Ogawa T, Kawata T, Gunji Y, Yamakawa Y, Ikeda K, Sasaki K. Biological-data-based finite-element stress analysis of mandibular bone with implant-supported overdenture. Comput Biol Med. 2014;54:44–52.

    Article  PubMed  Google Scholar 

  39. Lee H, Park S, Noh G. Biomechanical analysis of 4 types of short dental implants in a resorbed mandible. J Prosthet Dent. 2019;121(4):659–70.

    Article  PubMed  Google Scholar 

  40. Hansson S. A conical implant-abutment interface at the level of the marginal bone improves the distribution of stresses in the supporting bone. An axisymmetric finite element analysis. Clin Oral Implants Res. 2003;14(3):286–93.

    Article  PubMed  Google Scholar 

  41. Sevimay M, Turhan F, Kiliçarslan MA, Eskitascioglu G. Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown. J Prosthet Dent. 2005;93(3):227–34.

    Article  CAS  PubMed  Google Scholar 

  42. Fazi G, Tellini S, Vangi D, Branchi R. Three-dimensional finite element analysis of different implant configurations for a mandibular fixed prosthesis. Int J Oral Maxillofac Implants. 2011;26(4):752–9.

    PubMed  Google Scholar 

  43. van Zyl PP, Grundling NL, Jooste CH, Terblanche E. Three-dimensional finite element model of a human mandible incorporating six osseointegrated implants for stress analysis of mandibular cantilever prostheses. Int J Oral Maxillofac Implants. 1995;10(1):51–7.

    PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This study was funded by Medical Science and Technology Project of Zhejiang Province (2024KY008).

Author information

Authors and Affiliations

Authors

Contributions

S.X., T.X.D., C.K.J., X.Z.H., L.Y.F., Y.F., W.L.H. performed the experimental and analytical part. S.X., T.X.D., C.K.J., Y.F., W.L.H. wrote the main manuscript. S.X., X.Z.H., L.Y.F., W.L.H. prepared figures. All authors reviewed the manuscript.

Corresponding authors

Correspondence to Fan Yang or Linhong Wang.

Ethics declarations

Ethics approval and consent to participate

The studies involving human participants were reviewed and approved by the Ethics Committee of Zhejiang Provincial People’s Hospital (No. QT2023427). It was confirmed that informed consent was obtained from the subject of this study.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sun, X., Tang, X., Cheng, K. et al. Comparative biomechanics of all-on-4 and vertical implant placement in asymmetrical mandibular: a finite element study. BMC Oral Health 24, 425 (2024). https://doi.org/10.1186/s12903-024-04186-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12903-024-04186-w

Keywords