Skip to main content

Maxillary labial frenectomy: a randomized, controlled comparative study of two blue (445 nm) and infrared (980 nm) diode lasers versus surgical scalpel

Abstract

Background

This study aimed to compare the intra and postoperative complications of frenectomy procedure with a surgical scalpel versus 445 nm and 980 nm diode lasers.

Methods

This randomized controlled clinical trial was conducted on 174 patients requiring maxillary labial frenectomy. After completion of fixed orthodontic treatment and primary closure of maxillary diastema, the patients were randomly assigned into three groups (n = 58): group 1 (frenectomy via 445 nm diode laser, continuous-wave, 1.5 W), group 2 (frenectomy via 980 nm laser, continuous-wave, 1.7 W), and control group (V-Y plasty technique via scalpel). Intra-operative bleeding, discomfort in chewing and speaking, pain, and tissue healing were compared among the groups immediately, at 7 and 30 days postoperatively using the Kruskal-Wallis, Mann-Whitney, and Chi-square tests.

Results

Pain scores were significantly lower in group 1 compared to group 2 (immediately and day 7, P < 0.05). Significant faster tissue healing at days 7 and 30 were observed in group 1 compared to group 2 (P < 0.05). Group 1 was superior to the control group regarding lower intraoperative bleeding, discomfort in chewing and speaking (immediately and day 7), lower pain (immediately and day 7), and tissue healing (day 7) (P < 0.05 for all). Group 2 was significantly superior to the control group in lower intraoperative bleeding, discomfort in chewing and speaking (immediately and day 7), and better tissue healing (day 7) (P < 0.05 for all).

Conclusions

In conclusion, diode laser frenectomy resulted in significantly lower intra and postoperative complications compared to the scalpel. Moreover, 445 nm diode laser showed significantly superior effects compared to 980 nm diode laser.

Trial registration

The study protocol was registered on 29.10.2022 at the Iranian Registry of Clinical Trials (www.irct.ir) (registration number: IRCT20220630055326N1).

Peer Review reports

Background

A frenum is a thin fold of mucous membrane composed of muscle fibers and connective tissue. It connects the lip and buccal mucosa to the alveolar mucosa, gingiva, and underlying periosteum. High frenal attachments can lead to insufficient dental plaque removal and sulcular displacement due to the applied tension by frenal attachments [1]. In such cases, frenectomy should be necessarily performed. Frenectomy is also indicated in cases with diastema, gingival recession, labial movement limitation, and for some orthodontic and prosthodontic purposes [2, 3]. Relapse after completion of orthodontic treatment is one of the most challenging issues among orthodontists. It refers to the tendency of the teeth to return to their baseline position due to discontinuation of orthodontic forces [4]. Since a high-attached frenum is usually associated with midline diastema, frenectomy of the labial frenum is required to prevent relapse of maxillary midline diastema [5].

A frenectomy can be performed conventionally by a surgical scalpel, an electric scalpel (electro-surgery), or a laser (laser surgery) [6]. Laser technology relies on the utilization of monochromatic and coherent photons produced by the stimulated emission of radiation. The distinctive characteristics of laser light allow for its diverse applications in the field of medicine and surgery, particularly in the maxillofacial regions. Lasers can be employed for soft and hard tissue surgeries determined by the wavelength and irradiation parameters chosen. Examples of laser applications in maxillofacial surgery include incisional/excisional procedures, tissue ablation, and surgical hemostasis [7, 8]. Laser surgery has several advantages over conventional surgery, such as selective and precise interaction with the injured tissue, reduced scar tissue formation and tissue contraction, induction of complete hemostasis and subsequent improvement of the surgeon’s vision to the surgical field, and decreased need for suturing. Moreover, it reduces the risk of postoperative infection and the stress level of patients [9]. However, controversy exists regarding the superiority of frenectomy with laser or surgical scalpel. Some studies have reported higher levels of comfort, no or minimal postoperative pain, and superior mastication efficiency and speech following laser frenectomy [10]. Yadav et al. [11] reported lower bleeding and less need for analgesics in laser surgery compared to a scalpel. However, the clinical results were similar. Scalpel surgery is associated with surgical trauma, intraoperative bleeding, postoperative pain, and edema [1], while laser surgery has advantages such as less intraoperative bleeding, lower inflammation, and improved tissue healing. It also decreases the need for anesthetics and wound care, such as suturing and dressing, thus decreasing the patients’ fear of surgery [9].

A diode laser is a semi-conductive laser with high absorption in tissue chromophores such as melanin and particularly oxyhemoglobin, which makes it an available and safe modality for oral soft tissue procedures. Diode laser wavelengths between 800 and 980 nm are routinely used in dental practices [12, 13]. Recently, a novel 445 nm diode laser with blue light was introduced for surgical procedures [14]. This wavelength has maximum absorption in hemoglobin that enables it to fast soft tissue incision with minimal bleeding. It has been successfully used for many intraoral surgical procedures such as gingivectomy, impacted tooth exposure, and soft tissue biopsy with satisfactory results [15].

The comparison of diode lasers in the range of 800–900 nm to scalpel surgery has been previously documented [16, 17], but limited data are available on 445 nm blue laser [14]. Thus, this study aimed to compare the intra and postoperative complications following frenectomy using a surgical scalpel versus 445 nm and 980 nm diode lasers.

Methods

This study was conducted at the Orthodontics Department of the School of Dentistry, Mazandaran University of Medical Sciences, during 15 months between 2021 and 2022. The study protocol was approved by the Ethics Committee of the university (IR.MAZUMS.REC.1401.338) and registered at the Iranian Registry of Clinical Trials (IRCT20220630055326N1).

Trial design

A parallel-design randomized controlled clinical trial was carried out in which the experimental groups underwent maxillary frenectomy with 445 and 980 nm diode lasers, and the control group received conventional frenectomy with a surgical scalpel. The results were reported following the Consolidated Standards of Reporting Trials (CONSORT) guidelines [18].

Participants, eligibility criteria, and settings

The inclusion criteria were (I) patients under fixed orthodontic treatment of the maxilla or both jaws, (II) a midline diastema between the maxillary central incisors due to the presence of maxillary high frenal attachments, and (III) the need for a frenectomy. The exclusion criteria were (I) patients under prosthodontic or periodontal treatment of the anterior maxilla and (II) patients with dental diastema without high frenal attachments.

The samples were selected among patients referred to two private orthodontic offices and an orthodontic clinic in Sari and Behshahr cities, Mazandaran, Iran, by convenience sampling.

Interventions

A total of 174 patients were selected from those referred by their orthodontist for maxillary labial frenectomy following diastema closure prior to the bracket debonding process. Written informed consent was obtained from all participants prior to their enrollment. All patients had received fixed orthodontic treatment of the maxilla or both jaws. Three orthodontists performed the treatments with pre-adjusted 0.022’ 0.028-inch slot MBT brackets (American Orthodontics, Sheboygan, WI, USA), which lasted 15 to 24 months (mean: 17.1 months). The patients were then randomly assigned into three groups (n = 58) of 445 nm diode laser, 980 nm diode laser, and conventional scalpel surgery as the control group. First, infiltration anesthesia was induced by injection of 2% lidocaine plus 1:80,000 epinephrine (Darupakhsh, Tehran, Iran), similarly in all groups, then the procedure was conducted in each group as follows:

Control group (conventional scalpel surgery)

The frenum was held by a hemostat, and a V-shaped incision was made on its lower surface. The frenum was then displaced apically, and the V-shaped incision was converted to a Y-shaped incision, and sutured with 5 − 0 silk thread.

Experimental group 1 (445 nm diode laser)

Blue 445 nm diode laser (SiroLaser; Dentsply Sirona, Germany) with 1.5 W power in continuous-wave mode was used for a frenectomy. Upon initiation of irradiation, the 320-µm fiber tip was moved from the base towards the apex of the frenum in a non-contact mode without Suturing.

Experimental group 2 (980 nm diode laser)

Frenectomy was performed with a 980 nm diode laser (Doctor Smile, Italy) with 1.7 W power in continuous-wave mode. Upon initiation of irradiation, the 400-µm fiber tip was moved from the base towards the apex of the frenum with a brushing motion with no pressure and no suturing [5]. For safety purposes, both the patient and the operator wore protective glasses during laser irradiation in experimental groups.

Following frenectomy procedures in all groups, the patients received oral hygiene instructions and were instructed to use soft and cold food for the next 12 h [11]. Moreover, a 0.12% chlorhexidine gluconate mouth rinse (once a day for 1 min for five days) was prescribed [19]. Five hundred milligrams of acetaminophen (1–2 tablets) were also prescribed for pain relief if required, and the patients were asked to record the dosage and frequency of use.

Outcomes

Intraoperative bleeding, postoperative pain, discomfort in chewing and speaking, and tissue healing were the primary outcomes of the present study. There was no secondary outcome. To record the outcome measures, the following assessments were done immediately, on days 7 and 30 after surgery in an orthodontic office:

Bleeding

Intraoperative bleeding was scored and recorded by the surgeon using the following scoring system [20]:

  • Score 0: No bleeding

  • Score 1: Mild bleeding

  • Score 2: Moderate bleeding

  • Score 3: Severe bleeding

Pain and discomfort in chewing and speaking

Pain and discomfort in chewing and speaking were self-reported by patients immediately after surgery and at 7 and 30 days after treatment using a visual analog scale (VAS). Score 0 indicated minimal or no pain/discomfort, and 10 indicated maximum unbearable pain/discomfort [21].

Tissue healing

Tissue healing was assessed by a senior dental student immediately, at days 7 and 30 after surgery, using the following scoring system [22]:

  • Score 1: Complete epithelialization

  • Score 2: Incomplete epithelialization

  • Score 3: Presence of ulcer

  • Score 4: Tissue defect or necrosis

Sample size calculation

The sample size was calculated to be 174 patients (n = 58 in each group) according to Sezgin et al. study [23], assuming the mean and standard deviation of periodontal healing parameters to be 0.93 ± 0.24 in group 1, 0.84 ± 0.13 in group 2, and 0.90 ± 0.14 in group 3 at 45 days after surgery, study power of 90%, and 95% confidence interval, using the formula for comparison of two means and G-Power software.

Interim analyses and stopping guidelines

No interim analyses were performed, and no stopping guidelines were established.

Randomization

The patients were randomly assigned into three groups by Random Allocation Software using 6-series blocks.

Blinding

Blinding of patients, periodontist, and orthodontist was not possible in the present study. However, the examiner and the statistician who analyzed the data were blinded to the group allocation of patients and type of procedure.

Statistical analysis

Data were analyzed by SPSS software (version 26 SPSS Inc., IL, USA). The normal distribution of data was evaluated by the Shapiro-Wilk and Kolmogorov-Smirnov tests, which showed a non-normal distribution of all data (P < 0.05). Thus, the groups were compared regarding quantitative variables (intraoperative bleeding, pain, discomfort in chewing and speaking, and tissue healing) by the Kruskal-Wallis (for general comparisons) and Mann-Whitney (for pairwise comparisons) tests. The Kruskal-Wallis test was also used to compare the trend of change in quantitative variables over time among the three groups. The three groups were compared regarding age by the Kruskal-Wallis test and gender by the Chi-square test. The level of statistical significance was set at 0.05.

Results

Participant flow

The sample initially consisted of 174 patients, out of which 25 patients did not show up for the follow-ups and were excluded (Fig. 1). A total of 149 patients were eventually included, with a mean age of 18.6 years (female/ male: 92/57). Table 1 presents the demographic information of the participants in the study groups. There was no significant difference between groups regarding age (P = 0.381) or gender (P = 0.859).

Fig. 1
figure 1

CONSORT flow-diagram of patient selection and allocation

Table 1 Demographic information of the participants in the three groups

Subgroup analyses

Results for each outcome were measured and presented.

Intraoperative bleeding

A significant difference was found among the study groups (P = 0.000). Pairwise comparisons of the groups showed significantly lower intraoperative bleeding in both laser groups compared to the scalpel group (P = 0.000). The difference between the two laser groups was not significant (P = 0.207) (Fig. 2).

Fig. 2
figure 2

Mean score of intraoperative bleeding in the three groups (*p<0.05)

Pain

A significant difference was found in pain score among the three groups immediately (P = 0.000) and at 7 days after surgery (P = 0.002), but not at 30 days postoperatively (P = 0.157). Pairwise comparisons revealed significantly lower pain scores immediately (P = 0.000) and postoperatively at 7 days (P = 0.009) in the 445 nm laser group than the scalpel group. The pain score was significantly lower in the 445 nm laser group than the 980 nm laser group immediately after surgery (P = 0.000) and at 7 days (P = 0.001). No other significant differences were noted at any time point (P > 0.05) (Fig. 3).

Fig. 3
figure 3

Mean score of postoperative pain in the three groups at different time points

Analgesic intake

No analgesic intake was reported by patients in 445 nm and 980 nm diode laser groups. Four patients reported analgesic intake in the scalpel surgery group.

Discomfort in chewing and speaking

The three groups had a significant difference in this regard immediately (P = 0.000) and at 7 days (P = 0.007) after surgery, but not at 30 days postoperatively (P = 0.249). Pairwise comparisons revealed significantly lower discomfort in chewing and speaking immediately (P = 0.000) and at 7 days (P = 0.012) after surgery in 445 nm diode laser group than the scalpel group. Also, such problems were significantly lower in 980 nm laser group than the scalpel group immediately (P = 0.000) and at 7 days (P = 0.004) after surgery. The difference between the two laser groups was not significant at any time point (P > 0.05) (Fig. 4).

Fig. 4
figure 4

Mean score of discomfort in chewing and speaking in the three groups at different time points

Tissue healing

Tissue healing was significantly different among the three groups at 7 days postoperatively (P = 0.000), but not immediately (P = 0.334) or at day 30 (P = 0.074). Pairwise comparisons showed significantly faster tissue healing at 7 days in 445 nm laser group than the scalpel group (P = 0.000). Also, tissue healing was significantly higher in 980 nm laser group than the scalpel group at 7 days (P = 0.038). Tissue healing in 445 nm laser group was faster than that in 980 nm laser group at 7 (P = 0.003) and 30 (P = 0.024) days. No other significant differences were noted at any time points (P > 0.05) (Fig. 5). Figure 6 shows intraoral photographs of tissue healing over time among three groups.

Fig. 5
figure 5

Mean score of tissue healing in the three groups at different time points

Fig. 6
figure 6

Intraoral photographs of tissue healing after frenectomy by a surgical scalpel (upper row), 445 nm diode laser (middle row), and 980 nm diode laser (lower row) immediately after surgery (A), 7 days after surgery (B), and 30 days after surgery (C)

All of the pairwise and total differences between the three groups are shown in supplementary file S1.

Comparison of the trend of change in quantitative variables over time among the three groups

The three groups were significantly different in the trend of reduction in discomfort in chewing and speaking from the time of surgery to day 7 (P = 0.000) and from the time of surgery to day 30 (P = 0.000). The three groups had a significant difference in the trend of change in pain score between the time of surgery and 30 days (P = 0.000, and tissue healing between day 1 and day 7 (P = 0.005). No other significant differences were found in this respect (P > 0.05).

Pairwise comparisons of the groups regarding the reduction of pain and discomfort in chewing and speaking from the time of surgery to 7 and 30 days and tissue healing from day 1 to days 7 and 30 revealed significant differences between 445 nm diode laser and scalpel group in favor of 445 nm laser group in all variables at all the tested time intervals (P < 0.05) except for tissue healing from day 1 to day 30, which was not significantly different between the abovementioned two groups (P > 0.05). A pairwise comparison of 980 nm laser and scalpel group only revealed a significant difference in the reduction of discomfort in chewing and speaking from the time of surgery to day 7 (P = 0.000, and day 30 (P = 0.000) in favor of 980 nm laser group. Also, a significant difference between the two laser groups was only found in the trend of reduction of pain from the time of surgery to 30 months (P = 0.000) in favor of 445 nm laser group. No other significant differences were noted (P > 0.05).

Pairwise comparison of scalpel surgery with diode laser groups

Table 2 presents the mean and mean rank of quantitative variables in the scalpel surgery and diode laser groups. Significant differences were noted between the scalpel surgery and diode laser groups in intraoperative bleeding, discomfort in chewing and speaking, and pain immediately and 7 days postoperatively in favor of diode laser groups (P < 0.05).

Table 2 Mean and mean rank of quantitative variables in the scalpel surgery and diode laser groups

Comparison of the trend of change in quantitative variables over time between the scalpel surgery and diode laser groups

Table 3 compares the trend of reduction in pain and discomfort in chewing and speaking from the day of surgery to 7 and 30 days, and also tissue healing from day 1 to days 7 and 30 between the scalpel surgery and diode laser groups. As shown, significant differences were noted in all the variables in favor of the laser groups (P < 0.05), except for tissue healing between day 1 and day 30, which was not significantly different (P > 0.05).

Table 3 Comparison of the trend of reduction in pain and discomfort in chewing and speaking from the day of surgery to 7 and 30 days, and also tissue healing from day 1 to days 7 and 30 between the scalpel surgery and diode laser groups

Discussion

This study compared intraoperative bleeding, postoperative complications, and healing after a frenectomy procedure by a surgical scalpel versus 445 nm and 980 nm diode lasers. The results showed significantly lower intraoperative bleeding in laser groups compared to the scalpel group, with no significant differences between the laser groups. Gobbo et al. [24] reported similar results regarding the comparison of 445 nm and 980 nm lasers for excision of benign oral lesions. Similarly, no significant differences regarding bleeding scores between 445 nm and 940 nm diode lasers in gingival depigmentation were shown [20]. The superiority of 940 nm laser-mediated gingivectomy to a scalpel in terms of lower intraoperative bleeding was reported by Elif [25] and Sobouti et al. [26]. The optimal efficacy of diode laser in the reduction or elimination of intraoperative bleeding has been confirmed in previous studies [5, 27]. This hemostatic effect of laser gives the surgeon a much better view due to the laser-hemoglobin interaction [5].

Our findings revealed that the pain score in the laser groups was significantly lower than that in the surgical scalpel group. Immediately and at 7 days after surgery, the pain score in 445 nm laser group was significantly lower than that in the scalpel and 980 nm laser groups. This finding was consistent with several previous studies confirming lower pain scores in the laser group compared to scalpel surgery [20, 25, 26, 28]. Gobbo et al. [24] reported that 445 nm diode laser resulted in a lower pain score at 7 and 14 days compared to 970 nm laser. This discrepancy in the results may be attributed to using different anesthetic agents/techniques, types of surgery, and surgical sites [24].

In the present study, postoperative discomfort in chewing and speaking was significantly lower in laser groups than the scalpel surgery group immediately and at 7 days post-surgery. Similar results were reported in previous studies [22, 29]. Amaral et al. [30] compared 980 nm diode laser and scalpel surgery for removing fibrous hyperplasia and found no significant difference regarding discomfort in chewing and speaking between the two groups, which was in contrast to the present findings. This difference may be explained by the difference in surgical sites and type of surgery in the two studies. Also, patients with fibrous hyperplasia are usually denture wearers, which can explain the difference in the level of discomfort in chewing and speaking.

The current results showed that tissue healing accelerated in laser groups compared to the scalpel group at day 7, with superior results in 445 nm laser group. At 30 days postoperatively, tissue healing in the 445 nm laser group was significantly higher than in the 980 nm laser group. Noteworthy, we applied lasers in continues mode of irradiation. When comparing continuous and pulsed modes, it is observed that pulsed mode is linked with minimal thermal damage [31]. However, we ensured that the output power of the 445 and 980 nm lasers was maintained below 2 W ( 1.5 W), taking into account the device limitations and adhering to the safe settings validated by prior investigations [32]. Furthermore, the speed of ablation is enhanced through the use of a continuous setting [31]. The mechanism of action of laser is through enhancement of collagen synthesis and subsequent acceleration of healing of injured periodontal ligament [5]. This mechanism explains accelerated healing in laser groups [33]. The differences in tissue reactions observed between 445 nm and 980 nm diode lasers can be ascribed to the distinct optical characteristics of these wavelengths. Specifically, the 445 nm wavelength exhibits greater absorption in hemoglobin and melanin compared to other diode lasers, leading to enhanced cutting precision with reduced penetration depth and minimal thermal damages to underlying tissues [31, 33]. Reichelt et al. [34] compared wound healing following incision with 445 nm blue diode laser and 970 nm diode laser using a monolayer cell culture and reported faster tissue healing in the 445 nm laser group, consistent with our data. Palaia et al. [35], in their non-controlled clinical trial, performed 42 biopsies with 445 nm diode laser and reported normal tissue healing at 7 days post-surgery. They showed complete healing at 30 days after surgery, which was in agreement with the present findings. Qafmolla et al. [36] compared scalpel surgery and 980 nm diode laser for surgical removal of mucocele and reported faster tissue healing in the laser groups compared to the scalpel group at 4 weeks after surgery, which was in accordance with the present findings. Taher Agha and Polenik [20] found no significant difference in tissue healing between 445 nm and 940 nm diode lasers at 10 days after surgery, while a significant difference was noted between 445 and 980 nm diode lasers at 7 days in the present study. This controversy in the results of the two studies may be explained by the differences in the type of surgery, larger extent of the surgical field in depigmentation procedure, using different scales, different follow-up periods, and differences in laser wavelengths. Pezzi et al. [37], in their case report, described the removal of multiple human papilloma virus lesions with 445 nm diode laser, which resulted in complete tissue healing at 2 weeks after surgery; this finding was different from the present results, probably due to different healing rates of different tissues (mucosal tissue versus fibrotic tissue). Also, it should be noted that their study was a case report, so their results cannot be reliably generalized to all cases.

The current study aimed to compare the use of blue and infrared diode lasers with a surgical scalpel in terms of the complications during and after frenectomy procedures. Due to limited existing data on this subject, our results can serve as a reference for clinicians and researchers in choosing the most effective technique to reduce complications associated with frenectomy procedures. Additionally, the data obtained can assist researchers in developing further studies to confirm the findings of this research. The findings showed the 445 nm blue diode laser’s superiority in terms of bleeding, pain, discomfort while speaking and chewing, and tissue healing, indicating its usefulness and potential advantages over the 980 nm diode laser.

This study had some limitations. Blinding of the participants was not possible. Also, a few patients did not attend the follow-ups, which slightly reduced the final sample size. So, future studies with a larger sample size and inclusion of patients under 18 years of age are recommended. Also, the 445 nm diode laser should be compared with other lasers, such as CO2 and Nd: YAG lasers, in oral soft tissue surgical procedures. Due to the limitations of our laser device, the fiber diameters of laser groups were not exactly the same, so matching the fiber diameters should be considered in future studies. Our study utilized continuous mode of laser irradiation. It is important to evaluate the effectiveness of pulsed versus and continuous irradiation. Furthermore, we prescribed chlorhexidine mouthwash following frenectomy, since it is considered as the gold standard for oral cavity antiseptic treatment [38]. However, recent research has linked the use of chlorhexidine to potential side effects like delayed healing [38, 39], Therefore, it may be advisable for future studies to explore alternative topical medications.

Conclusion

In conclusion, within the limitations of the present study, the results showed that frenectomy with diode lasers was associated with significantly lower intraoperative bleeding, postoperative pain, discomfort in chewing and speaking, and faster healing compared with scalpel surgery. Also, 445 nm blue diode laser was optimal for frenectomy and superior to 980 nm diode laser in terms of the lower level of postoperative pain and faster tissue healing.

Data availability

All of the data is provided within the manuscript, except for the pairwise and total differences between the three groups, which are shown in supplementary file S1.

References

  1. Naini F, Gill D. Oral surgery: labial frenectomy: indications and practical implications. Br Dent J. 2018;225(3):199–200.

    Article  CAS  PubMed  Google Scholar 

  2. Gontijo I, Navarro RS, Haypek P, Ciamponi AL, Haddad AE. The applications of diode and Er: YAG lasers in labial frenectomy in infant patients. J Dent Child. 2005;72(1):10–5.

    Google Scholar 

  3. Aldelaimi TN, Mahmood AS. Laser-assisted frenectomy using 980nm diode laser. J Dent Oral Disord Ther. 2014;2(4):1–6.

    Article  Google Scholar 

  4. Al-Jasser R, Al-Subaie M, Al-Jasser N, Al-Rasheed A. Rotational relapse of anterior teeth following orthodontic treatment and circumferential supracrestal fiberotomy. Saudi Dent J. 2020;32(6):293–9.

    Article  PubMed  Google Scholar 

  5. Sobouti F, Dadgar S, Salehabadi N, Moallem Savasari A. Diode laser chairside frenectomy in orthodontics: a case series (DIODE LASER FRENECTOMY: CASE SERIES). Clin Case Rep. 2021;9(8):e04632.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Gujjari SK, Shubhashini P. Frenectomy: a review with the reports of surgical techniques. J Clin Diagn Research: JCDR. 2012;6(9):1587.

    Google Scholar 

  7. Srivastava S, Ebenezer V, Balakrishnan R. Lasers in oral and maxillofacial Surgery-A review. J Pharm Sci Res. 2023;15(3):1057–9.

    CAS  Google Scholar 

  8. Sobouti F, Dadgar S, Salehi A, Kalantari NR, Aryana M, Goli HR, et al. In Vitro comparative evaluation of the efficacy of Antimicrobial Photodynamic Therapy, Chlorhexidine, Sodium Fluoride, and Hydrogen Peroxide for Acrylic Resin Disinfection. J Lasers Med Sci. 2023;14:e52.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Protásio ACR, Galvão EL, Falci SGM. Laser techniques or scalpel incision for labial frenectomy: a meta-analysis. J Oral Maxillofac Surg. 2019;18(4):490–9.

    Article  Google Scholar 

  10. Olivi M, Genovese M, Olivi G. Laser labial frenectomy: a simplified and predictable technique. Retrospective clinical study. Eur J Pediatr Dentistry. 2018;19(1):56–60.

    CAS  Google Scholar 

  11. Yadav RK, Verma UP, Sajjanhar I, Tiwari R. Frenectomy with conventional scalpel and nd: YAG laser technique: a comparative evaluation. J Indian Soc Periodontology. 2019;23(1):48–52.

    Article  Google Scholar 

  12. Ibacache MCT, Arcos P, Sanchez S, Weinstein G. Use of diode lasers in dentistry. Clin Dentistry Reviewed. 2020;4(1):1–7.

    Article  Google Scholar 

  13. Aldelaimi AA, Ahmed RF, Enezei HH, Aldelaimi TN. Gummy smile esthetic correction with 940 nm Diode Laser. Int Med J. 2019;26(6):1–3.

    Google Scholar 

  14. Strakas D, Franzen R. The blue wavelengths in laser dentistry: a review of current literature. Lasers Dent Sci. 2023;7(2):97–9.

    Article  Google Scholar 

  15. Fornaini C, Fekrazad R, Rocca J-P, Zhang S, Merigo E. Use of blue and blue-violet lasers in dentistry: a narrative review. J Lasers Med Sci. 2021;12:e31.

    Article  PubMed  PubMed Central  Google Scholar 

  16. Lesniewski A, Estrin N, Romanos GE. Comparing the Use of Diode lasers to light-emitting diode phototherapy in oral soft and hard tissue procedures: a Literature Review. Photobiomodulation, Photomedicine, and laser surgery. 2022;40(8):522–31.

  17. Liaqat S, Qayyum H, Rafaqat Z, Qadir A, Fayyaz S, Khan A et al. Laser as an innovative Tool, its implications and advances in Dentistry: a systematic review. J Photochem Photobiology. 2022:100148.

  18. Schulz KF, Altman DG, Moher D. CONSORT 2010 statement: updated guidelines for reporting parallel group randomised trials. J Pharmacol Pharmacotherapeutics. 2010;1(2):100–7.

    Article  Google Scholar 

  19. Tancredi S, De Angelis P, Marra M, Lopez MA, Manicone PF, Passarelli PC, et al. Clinical comparison of Diode Laser assisted v-Shape frenectomy and Conventional Surgical Method as Treatment of Ankyloglossia. Healthcare. 2022;10(1):89.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Taher Agha M, Polenik P. Laser treatment for melanin gingival pigmentations: a comparison study for 3 laser wavelengths 2780, 940, and 445 nm. International journal of dentistry. 2020;2020.

  21. Akpınar A, Toker H, Lektemur Alpan A, Çalışır M. Postoperative discomfort after nd: YAG laser and conventional frenectomy: comparison of both genders. Aust Dent J. 2016;61(1):71–5.

    Article  PubMed  Google Scholar 

  22. Singh P, Nath S. Diode laser versus conventional technique for frenectomy-A randomised controlled clinical trial. Int J Appl Dent Sci. 2019;5(5):4–7.

    Google Scholar 

  23. Sezgin G, Öztürk Özener H, Meseli SE, Kuru L. Evaluation of patient’s perceptions, healing, and reattachment after conventional and diode laser frenectomy: a three-arm randomized clinical trial. Photobiomodulation Photomed Laser Surg. 2020;38(9):552–9.

    Article  CAS  Google Scholar 

  24. Gobbo M, Bussani R, Perinetti G, Rupel K, Bevilacqua L, Ottaviani G, et al. Blue diode laser versus traditional infrared diode laser and quantic molecular resonance scalpel: clinical and histological findings after excisional biopsy of benign oral lesions. J Biomed Opt. 2017;22(12):121602.

    Article  PubMed  Google Scholar 

  25. Elif Ö. Comparison of gingivectomy procedures for patient satisfaction: conventional and diode laser surgery. Selcuk Dent J. 2017;4(1):6–9.

    Article  Google Scholar 

  26. Sobouti F, Rakhshan V, Chiniforush N, Khatami M. Effects of laser-assisted cosmetic smile lift gingivectomy on postoperative bleeding and pain in fixed orthodontic patients: a controlled clinical trial. Prog Orthodont. 2014;15(1):1–5.

    Article  Google Scholar 

  27. Elanchezhiyan S, Renukadevi R, Vennila K. Comparison of diode laser-assisted surgery and conventional surgery in the management of hereditary ankyloglossia in siblings: a case report with scientific review. Lasers Med Sci. 2013;28(1):7–12.

    Article  CAS  PubMed  Google Scholar 

  28. Aldelaimi TN, Khalil AA. Clinical application of diode laser (980 nm) in maxillofacial surgical procedures. J Craniofac Surg. 2015;26(4):1220–3.

    Article  PubMed  Google Scholar 

  29. Uraz A, Çetiner F, Cula S, Guler B, Oztoprak S. Patient perceptions and clinical efficacy of labial frenectomies using diode laser versus conventional techniques. J Stomatology oral Maxillofacial Surg. 2018;119(3):182–6.

    Article  CAS  Google Scholar 

  30. Amaral M, De Ávila J, Abreu M, Mesquita R. Diode laser surgery versus scalpel surgery in the treatment of fibrous hyperplasia: a randomized clinical trial. Int J Oral Maxillofac Surg. 2015;44(11):1383–9.

    Article  CAS  PubMed  Google Scholar 

  31. Michalik M, Szymańczyk J, Stajnke M, Ochrymiuk T, Cenian A. Medical applications of diode lasers: pulsed versus continuous wave (cw) regime. Micromachines. 2021;12(6):710.

    Article  PubMed  PubMed Central  Google Scholar 

  32. Lanka J, Gopalkrishna P, Kumar S. Management of Aberrant Frenal Attachments in Adults by Scalpel Method and 980 nm Diode Laser. Case Reports in Dentistry. 2023;2023.

  33. Etemadi A, Namin ST, Hodjat M, Kosarieh E, Hakimiha N. Assessment of the Photobiomodulation effect of a blue diode laser on the proliferation and migration of cultured human gingival fibroblast cells: a preliminary in vitro study. J Lasers Med Sci. 2020;11(4):491–6.

    Article  PubMed  PubMed Central  Google Scholar 

  34. Reichelt J, Winter J, Meister J, Frentzen M, Kraus D. A novel blue light laser system for surgical applications in dentistry: evaluation of specific laser-tissue interactions in monolayer cultures. Clin Oral Invest. 2017;21(4):985–94.

    Article  Google Scholar 

  35. Palaia G, D’Alessandro L, Pergolini D, Carletti R, Di Gioia CR, Romeo U. In vivo clinical and histological thermal effect of a 445 nm diode laser on oral soft tissues during a biopsy. J Oral Sci. 2021:20–0665.

  36. Qafmolla A, Bardhoshi M, Gutknecht N, Bardhoshi E. Evaluation of early and long term results of the treatment of mucocele of the lip using 980 nm diode laser. Eur Sci J. 2014;10(6):334–40.

    Google Scholar 

  37. Pezzi ME, Passerini P, Frontera M, Vescovi P, Meleti M. Recurrent p16-Positive human papillomavirus (HPV) Associated oral lesions treated with a Diode laser: a Case Report. J Dentistry Indonesia. 2019;26(2):109–13.

    Google Scholar 

  38. Pilloni A, Ceccarelli S, Bosco D, Gerini G, Marchese C, Marini L, et al. Effect of chlorhexidine digluconate in early wound healing of human gingival tissues. A histological, immunohistochemical and biomolecular analysis. Antibiotics. 2021;10(10):1192.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  39. Deus FP, Ouanounou A. Chlorhexidine in dentistry: pharmacology, uses, and adverse effects. Int Dent J. 2022;72(3):269–77.

    Article  Google Scholar 

Download references

Acknowledgements

This study was supported by Dental Research Center, Mazandaran University of Medical Sciences, Sari, Iran (Grant No: 14825).

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Contributions

FS: conceptualization, methodology, investigation, supervision, project administration; AMS: software, formal analysis, writing - original draft; MA: investigation, data curation, writing - original draft; NH: validation, visualization, writing - review & editing; SD: conceptualization, methodology, validation, investigation, supervision, writing - review & editing; All authors read and approved the final manuscript.

Corresponding author

Correspondence to Sepideh Dadgar.

Ethics declarations

Ethics approval and consent to participate

The study protocol was approved by the Research Ethics Committee of the Mazandaran University of Medical Sciences (IR.MAZUMS.REC.1401.338) and registered at the Iranian Registry of Clinical Trials (www.irct.ir) (registration number: IRCT20220630055326N1). Written informed consent was obtained from all participants prior to their enrollment in the study.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary Material 1

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sobouti, F., Moallem Savasari, A., Aryana, M. et al. Maxillary labial frenectomy: a randomized, controlled comparative study of two blue (445 nm) and infrared (980 nm) diode lasers versus surgical scalpel. BMC Oral Health 24, 843 (2024). https://doi.org/10.1186/s12903-024-04364-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12903-024-04364-w

Keywords