Skip to main content

Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study

Abstract

Background

Early accurate radiographic assessment of peri-implant bone condition is highly important to avoid excessive loss of supporting bone and implant failure. Cone beam computed tomography (CBCT) is the radiographic technique of choice if peri-implant dehiscence and fenestration defects are suspected. The higher radiation dose and the presence of beam hardening artifacts are the main drawbacks of CBCT imaging techniques. This study aims to evaluate the influence of low-dose cone beam computed tomography (LD-CBCT) and metal artifact reduction (MAR) tool on the assessment of peri-implant dehiscence and fenestration.

Methodology

Thirty titanium implants were inserted into bovine rib blocks. Twenty had standardized bone defects (10 with dehiscence and 10 with fenestration), while the remaining 10 were used as control group with no defects. Radiographic examinations held with high‐definition CBCT (HD-CBCT) and LD-CBCT with and without application of MAR tool. Images were assessed by four examiners for the presence or absence of peri-implant defects. The area under the area under the receiver operating characteristic (ROC) curve (AUC), sensitivity, specificity, and accuracy were calculated for all radiographic protocols.

Results

In the absence of MAR tool, there was no difference in AUC and diagnostic values between LD-CBCT and HD-CBCT for detection of both defects. When the MAR tool was applied, the AUC values, sensitivity, and accuracy were higher in HD-CBCT than in LD-CBCT for the detection of both defects, especially for the dehiscence, while specificity remained the same.

Conclusion

LD-CBCT can be used in the evaluation of peri-implant dehiscence and fenestration without any decrease in diagnostic accuracy. The application of MAR tool decrease the diagnostic ability of both defects, especially for the detection of dehiscence defects.

Peer Review reports

Background

Since the introduction of the Bränemark implant system, dental implants have become an increasingly popular therapeutic modality for tooth loss [1]. Unfortunately, the success rate of functional implants and their prosthetic restorations is influenced by biological and mechanical conditions. The success of implant therapy is dependent on the absence of mobility, soft tissue inflammation, abscess, or pain [2]. Appropriate bone volume around the implants is essential for the primary stability of the implant. So, it has been reported that it is critical to have at least 1 mm of bone surrounding the implant in all directions. Inability to obtain complete coverage of the implant by bone may increase the risk of peri-implant mucositis, periimplantitis, and peri-implant defects [2, 3].

Insufficient amounts of bone surrounding the implants and incorrect position of the dental implant significantly increase the probability of peri-implant bone defects such as dehiscence and fenestration. Dehiscence and fenestration defects involve bone denudation over the cervical or radicular implant surface. The absence of bone from the implant’s cervical portion is called peri-implant dehiscence, while peri-implant fenestration is the absence of bone in a portion of the implant with the implant’s coronal third is covered by bone [4, 5].

It was thought that the presence of peri-implant defects like dehiscence and fenestration would affect the survival and success rate of the dental implant and could cause total loss of the implant. The extent of peri-implant bone loss and the configuration of the defect have a major impact on the treatment outcomes of peri-implantitis [5, 6]. As a result, early accurate radiographic assessment of bone defects surrounding dental implants is crucial [7].

Radiographic imaging plays an important role in the evaluation of peri-implantitis and peri-implant bone defects. Intraoral periapical radiography with the parallel technique is the gold standard radiographic technique for postsurgical assessment of dental implants. It has a low patient radiation dose, low cost, and high resolution [8]. However, it is not appropriate for detecting crestal bone loss in the buccal and lingual aspects of dental implants because of the two-dimensional (2D) representation of the three-dimensional (3D) anatomical structures. This modality is only appropriate for assessing the interproximal bone level and it is not useful in determining whether peri-implant dehiscence or fenestration is present or not [7, 9, 10].

Cone beam computed tomography (CBCT) was introduced into the dento-maxillofacial field to overcome the limitations of two-dimensional imaging techniques [11]. It enables the visualization of buccal and lingual cortical bone around implants. Using CBCT improves the diagnostic accuracy at the expense of greater cost and radiation exposure. The higher diagnostic accuracy allows earlier detection of bone defects and interventions to control further bone loss [7, 12]. According to the ALADA principle (As Low As Diagnostically Acceptable), CBCT must be justified based on an individual's needs and provide benefits to the patient that outweigh the risks [13, 14].

Low-dose cone beam computed tomography (LD-CBCT) protocols have recently become available, which can reduce exposure factors without sacrificing image quality for diagnostic purposes. It can be done by either using pre-set dose reduction settings or manually adjusting scanning parameters provided by the machine. Low-dose techniques can be accomplished by decreasing the tube voltage, tube current, scanning time, projection image number, using an incomplete rotation angle (180° rather than 360° rotation), and/or increasing the voxel size. For optimization of radiation dose, researchers preferred tube current reduction over kVp reduction for achieving acceptable image quality with CBCT [15,16,17].

In addition to the higher radiation dose and cost, image artifacts is considered one of the drawbacks of CBCT imaging technique. Beam hardening, noise, and scattered radiation can decrease the quality of CBCT images. Metal artifacts produced by high density objects like dental titanium implants, cause beam hardening and streaking artifacts. The selective attenuation of low-energy x-ray photons by allowing the passage of high-energy photons is called beam hardening artifact, which results in a dark band surrounding hyperdense object. Streaking artifact is caused by scattered radiation from hyperdense objects which is seen as hyperdensity lines arising from the metallic object [18, 19]. These artifacts affect the visibility of areas surrounding dental implants, therefore, may affects the diagnostic ability of CBCT in the detection of peri-implant bone defects [20].

According to the literature, different methods have been used to decrease metal artifacts in CBCT images, such as using metallic filters, anti-scatter grids, or choosing a smaller field of view. Moreover, newer metal artifact reduction (MAR) algorithms have been introduced to minimize the artifacts of beam hardening in the final images and to improve image quality [21]. The use of MAR algorithms for artifact reduction is becoming increasingly common. The effect of MAR algorithms on different diagnostic tasks are now being investigated by many researchers, and the findings are still controversial.

There are not enough studies that clarify the effect of using the LD-CBCT protocol and MAR algorithm in the assessment of peri-implant bone defects [12, 15]. Thus, the primary aim of this study was to compare the diagnostic accuracy of low-dose cone beam computed tomography (LD-CBCT) to high-definition cone beam computed tomography (HD-CBCT) in the evaluation of peri-implant fenestration and dehiscence defects. The secondary aim was to investigate the effect of using the metal artifact reduction (MAR) algorithm in addition to both the LD-CBCT and HD-CBCT on the detection of peri-implant bone defects.

Methods

Sample selection and preparation

This in vitro diagnostic accuracy study was planned and performed according to STARD guidelines [22]. Fresh bovine ribs were acquired from a local butcher and prepared by removing the overlying soft tissue, then divided into 30 blocks of equal dimensions (20 mm in length). The width of the superior surface of each block was measured, and only blocks with a width of 7 to 10 mm were chosen [23]. Dried ribs, ribs with pre-existing defects, and very thick or thin ribs were excluded [2, 7, 9]. The sample size was calculated to be 30 (10 for the control group, 10 for the fenestration group, and 10 for the dehiscence group) with an alpha error of 5% and a study power of 80% [7, 24].

The blocks were flattened by performing an osteotomy on the superior and inferior borders of the block. The buccal plate of bone was represented by the anterior or convex surface of the rib, whereas the lingual plate of bone was represented by the posterior or concave surface. The bovine blocks were kept frozen during all the study procedures to preserve the bone marrow's hydration and integrity [7, 9].

Implant osteotomies measuring 3.6 mm × 12 mm were prepared in the blocks following the manufacturer's drilling sequence. After implant site preparation, the bone blocks were randomly divided into three equal groups: the dehiscence defect group, the fenestration defect group, and the no defect control group. The blocks of the three groups were assigned different numbers randomly. Then the defects were created mechanically by a round diamond bur (MANI, Tochigi, Japan). Dehiscence defects were prepared as half-elliptical defects on the superior edge of the buccal sides where the cervical portion of the implant would be inserted. The fenestration defects were prepared on the buccal sides of the bone blocks 10 mm from the superior edge as an elliptical defect form. Each defect was prepared with care not to exceed 2 mm in width and 3 mm in length, as this is the important threshold used by previous research (Fig. 1) [2, 23, 25].

Fig. 1
figure 1

Sample preparation and defect creation. a bovine rib block before implant osteotomy. bd implant site preparation with drilling sequence. eg dehiscence defect creation. h, i fenestration defect creation

Following the creation of bone defects, 30 titanium implants (Dual Implant, Titan Industries, Egypt®) measuring 3.6 mm × 12 mm were inserted into the osteotomies of all the bovine rib blocks. In the control group, implants were inserted in the absence of any defect. Just one implant was placed into each bovine rib block to prevent image quality degradation due to metal artifacts from nearby implants. After that, the bone blocks were coated with a 1.5 mm layer of pink wax to mimic the soft tissue surrounding the alveolar bone and to maintain an equivalent x-ray beam attenuation (Fig. 2) [3, 26, 27].

Fig. 2
figure 2

Insertion of titanium implants into the three groups of the blocks (dehiscence, fenestration, control)

Radiographic examination

To standardized the position of bone blocks within the field of view during the radiographic examination procedure, a piece of plastic foam with a central groove was developed to accommodate all the bone blocks [9].

Cone beam computed tomography images were acquired using the Green Ct machine (Green Ct, Vatech, Hwaseong, Republic of Korea). Images were taken with two different exposure protocols: high-definition CBCT (HD-CBCT) and low-dose CBCT (LD-CBCT), once with the activation of the machine MAR tool and again without the MAR tool activation. So, each bone block was subjected to four radiographic examinations: HD with MAR, HD without MAR, LD with MAR, and LD without MAR. For HD-CBCT, the following parameters were adjusted: 5 × 5 cm 2 FOV, 90 kVp, 12 mA, 9 s scan time, and 0.08 mm voxel size with a 396.92 mGycm2 dose area product (DAP). For LD-CBCT, the parameters were as follows: 5 × 5 cm2 FOV, 90 kVp, 2 mA, 5.9 s scan time, and 0.08 mm voxel size with a 48.7 mGycm2 dose area product DAP. All bone blocks were scanned using each of the four radiographic protocols. The original CBCT images have been imported in the form of Digital Imaging and Communications in Medicine (DICOM) data for examination using Cybermed International's OnDemand3DTM version 1.0.10.4304 software (Seoul, Republic of Korea) (Figs. 3, 4, 5).

Fig. 3
figure 3

Sagittal and axial images with simulated peri-implant dehiscence defect obtanied with different four radiographic protocols. a High-dose CBCT without MAR. b Low-dose CBCT without MAR. c High-dose with MAR. d Low-dose CBCT with MAR

Fig. 4
figure 4

Sagittal and axial images with simulated peri-implant fenestration defect obtained with different four radiographic protocols. a High-dose CBCT without MAR. b Low-dose CBCT without MAR. c High-dose with MAR. d Low-dose CBCT with MAR

Fig. 5
figure 5

Sagittal and axial images with no peri-implant defect obtained with different four radiographic protocols. a High-dose CBCT without MAR. b Low-dose CBCT without MAR. c High-dose with MAR. d Low-dose CBCT with MAR

Radiographic evaluation

A total of 120 datasets of CBCT images were examined by four examiners: three radiologists (one with more than 5 years’ experience and two with 3 years’ experience) and one periodontist. Prior to the initial evaluation, a calibration session was conducted using images from each radiographic protocol to standardize the radiological assessment of peri-implant defects. The image numbers were also shuffled to reduce the possibility of bias. Also, the analysis was performed in a new random sequence after 2 weeks to minimize learning bias and to obtain intra-examiner reliability.

During the evaluation sessions, the examiners were blinded and unaware of whether a defect was present or not, but they were allowed to scroll and view images of the entire volume in the three planes (axial, coronal, and sagittal), alter the brightness and contrast, and use the zoom tool. All images were viewed under the same conditions in a dimly lit room on a monitor with a 15.6" FHD 1920 × 1080 IPS display with an NVIDIA GeForce GTX 1650 graphic card. They assessed each image with MPR mode for the presence or absence of peri-implant bone defects using a five-point rank scale proposed by De-Azevedo-Vaz et al. [2]: “1-definitely absent, 2-probably absent, 3-uncertain, 4-probably present, 5-definitely present”.

Statistical analysis

Data was analyzed using MedCalc Statistical Software version 19.0.5 (MedCalc Software bvba, Ostend, Belgium; https://www.medcalc.org; 2019) and significance was set at p value < 0.05. A receiver operating curve (ROC) was used to determine the diagnostic accuracy of the radiographic modalities, with multiple pairwise comparisons between the AUCs generated for the radiographic modalities using DeLong et al. [28] method. For all radiographic modalities used in the study, sensitivity (correctly identifying the presence of a defect), specificity (correctly identifying the absence of a defect), and test accuracy (percentage of correctness) were calculated using a five-point scale, where ranks 1, 2, and 3 representing absence of the defect, and ranks of 4 and 5 indicating its presence as it mentioned by Dave et al. [7]

Results

The inter-observer reliability was calculated and, the intraclass correlation coefficient (ICC) ranged from 0.887 to 0.984, indicating very good to excellent agreement between observers in all the radiographic modalities. The intra-observer reliability was calculated and, the intra ICC ranged from 0.939 to 0.990 indicating excellent agreement across time (Table 1).

Table 1 Shows intra-observer and inter-observer reliability

The area under the ROC curve (AUC values) for detection of fenestration and dehiscence defects was calculated for both HD-CBCT and LD-CBCT with and without MAR tool (Tables 2, 3). AUC values were between 0.90 and 1.00 for the detection of fenestration defects and between 0.68 and 1.00 for dehiscence. The fenestration defect AUC values were higher than those for dehiscence defects when the MAR tool was applied. According to AUC values, application of the MAR tool with either HD-CBCT or LD-CBCT decreased the diagnostic accuracy for detection of both fenestration and dehiscence defects.

Table 2 Shows area under (ROC) curve (AUC), standard error (SE), confidence interval (CI) for fenestration group
Table 3 Shows area under (ROC) curve (AUC), standard error (SE), confidence Interval (CI) for dehiscence group

Sensitivity, specificity, and accuracy for all radiographic techniques were calculated independently for both fenestration and dehiscence defects (Table 4). For HD-CBCT and LD-CBCT without the application of MAR tool, all of these values were the same for fenestration and dehiscence. When the MAR tool was applied, the diagnostic accuracy for both scanning protocols was significantly decreased. However, the sensitivity, and accuracy values were higher for HD-CBCT than for LD-CBCT for both fenestration and dehiscence defect detection, while specificity values were the same in both cases. Also, the diagnostic values for fenestration defects were higher than those for dehiscence.

Table 4 Shows diagnostic values for fenestration and dehiscence

Discussion

Biomechanical complications and accumulation of bacterial biofilm are the main causative factors in the development of peri-implantitis and peri-implant bone defects. Fenestrations and dehiscences can affect the success of implant therapy and can subsequently result in progressive bone loss and implant failure. As a result, early detection of these defects is important for preserving the implants with the aid of radiographic examinations [7, 29]. According to several studies [3, 9, 10, 30], periapical and panoramic radiographs cannot be used for the evaluation of interproximal bone level around dental implants, and CBCT should be employed when peri-implant dehiscence or fenestration is suspected.

Bovine rib bone blocks were used in the current study because it was believed that the bone density and proportions between the cancellous and cortical bone in bovine ribs were similar to those in the mandible of humans. This was consistent with de‐Azevedo‐Vaz et al. [2], Saberi et al. [9], and Schwindling et al. [31], who used bovine rib models to evaluate peri-implant bone defects. For the selection of acquisition parameters, the smallest FOV of the machine was chosen as it was recommended by Pinheiro et al. [32] to decrease the artifacts from the surrounding tissues and optimize the radiation dose. Based on Vasconcelos et al. [33] findings, voxel size didn’t have an effect on beam hardening artifacts production next to titanium implants, so we chose a voxel size of 0.08 to enhance image quality and improve spatial resolution. For tube voltage, we choose 90 kVp for all radiographic protocols as it was suggested by Pauwels et al. [34], who reported that 90 kVp gives the optimum image quality and less noise than images obtained with 75 kVp.

For optimization of radiation dose, several previous studies [35,36,37] concluded that decreasing tube current in the presence of metallic objects may increase the magnitude of artifacts but has no significant effect on the diagnostic ability of CBCT images. Fontenele et al. [35] showed that decreasing the tube current had no effect on the detection accuracy of vertical root fractures in the endodontically treated teeth next to zirconium implants. Also, Sawicki et al. [36] found that the difference in tube current didn’t affect the assessment of peri-implant bone level. Based on these findings, we chose 12 mA (the highest mA offered by the CBCT machine used) for HD-CBCT and 2 mA (the least mA offered by the CBCT machine used) for LD-CBCT.

Low-dose CBCT protocols are associated with a significant decrease in radiation dose in comparison to high-dose protocols. For the current study, the dose area products of the protocols used were 48.7 mGycm2 for LD-CBCT and 396.92 mGycm2 for HD-CBCT. Despite the representation of the dose in the form of DAP, it still indicates that the use of the low-dose protocol significantly decreases the dose when compared with the high-definition protocol. Although the reduction in radiation dose of LD-CBCT protocols is significant, an insufficient amount of research is available for its application in implant assessment. A study conducted by Liljeholm et al. [38] showed that ultra-low dose protocols of CBCT can be used for pre-implant radiographic assessment. Another study held by Cardarelli et al. [39] stated that using a low-dose protocol with 180 degrees rotation angle has a significant effect on decreasing metal artifacts around the implants and can be used to assess peri-implant bone level. However, for detection of peri-implant dehiscence and fenestrations, de‐Azevedo‐Vaz et al. [5] recommended using the full scan protocol (360 degrees) for the detection of peri-implant dehiscence.

The results of our study showed that there was no statistically significant difference in fenestration and dehiscence detection between HD-CBCT and LD-CBCT when the MAR tool was not applied. Our study results support a previous study conducted by Schwindling et al. [31] to compare the accuracy of HD-CBCT and LD-CBCT in the detection and classification of peri-implant bone lesions, which stated that there was no significant difference in the diagnostic accuracy of both protocols. Also, in a study conducted by Schriber et al. [40] no difference was found between low-dose and high-dose protocols in the detection of buccal peri-implant dehiscence defects. Our results were in line with the results of Aktuna-Belgin et al. [41] who evaluated the efficiency of two different CBCT doses (low dose and ultra-low dose) in the detection of peri-implant fenestration and dehiscence defects, and they found that the diagnostic accuracy was not affected in the two protocols used.

The incorporation of MAR algorithms into CBCT units by manufacturers has resulted in a steady growth in the utilization of these approaches. Different previous studies evaluated the effects of the MAR algorithm on the artifacts of CBCT images, and they stated that it can reduce the standard deviations of grey value and increase image quality by increasing contrast to noise ratio (CNR) [42,43,44,45]. The application of these strategies has been examined, but the findings have been uneven. Fontenele et al. [46] found that the MAR tool has a negative effect on the diagnostic accuracy of vertical root fracture in the presence of intracanal filling. Also, Kamburoglu et al. [47] evaluated the effects of four MAR protocols (off, low, medium, and high) for the assessment of periodontal and peri-implant defects, and they found no difference in diagnostic accuracy with any MAR protocol. However, Bagis et al. [48] recommended the use of the MAR tool for the detection of peri-implant fenestration defects.

According to the results of the current study, using the MAR tool decreased AUC, sensitivity, and accuracy values when applied to both HD-CBCT and LD-CBCT. Only specificity values were the same whether MAR tool was applied or not. It means that the detection of true defect blocks was significantly decreased by the application of MAR tool, while the no defect intact blocks could be detected correctly with and without the application of MAR tool with no difference. This was consistent with the findings of both De-Azevedo-Vaz et al. [2] and Sheikhi et al. [28]. De-Azevedo-Vaz et al. [2] stated that the MAR algorithm didn’t improve the diagnostic accuracy of fenestration and dehiscences. Sheikhi et al. [23] found that sensitivity and accuracy values for fenestration and dehiscence defects were higher when the MAR algorithm was absent, but specificity was equal when MAR was present and absent, which was almost similar to our findings.

In the current study, when MAR tool was applied, the AUC values and the diagnostic values revealed that peri-implant fenestrations were more correctly diagnosed than peri-implant dehiscences. Similar findings have been reported by de-Azevedo-Vaz et al. [2, 5], Sheikhi et al. [23], and Salemi et al. [26], and they explained these findings by claiming that as dehiscence has just an inferior border, it is more difficult to identify than fenestration, which has both superior and inferior borders.

MAR algorithms employ several methods to minimize metal artifacts, such as iterative reconstruction methods, projection-correction methods, and reconstruction-correction methods. The majority of these methods consider metal artifacts as missing data [49, 50]. The technique of the MAR algorithm of the CBCT machine used in the study was not explained by the manufacturer. Unfortunately, the disadvantages of these techniques include the elimination of all attenuation data from high-density objects. When using the MAR algorithm, there is always lost data that cannot be reconstructed, which may cause modification in the image and can affect the diagnostic accuracy [43, 51]. Also, according to Fontenele and Mancini et al. [42, 52] the impact of the MAR algorithm becomes more prominent when the image artifacts are increased. Hence, it explains the decrease in the diagnostic ability of LD-CBCT compared with HD-CBCT when the MAR tool was applied to both in the current study, as we changed the tube current from 12 mA in HD-CBCT to 2 mA in LD-CBCT. Thus, the production of artifacts from the implants was increased [52, 53].

The in vitro design is one of the limitations of our study. In clinical situations, patient movement artifacts may affect the quality of the final image and affect the diagnostic accuracy, but this is the only ethically appropriate protocol to assess the recommended parameters without subjecting patients to unneeded CBCT scans[19]. Also, the presence of metal restorations, teeth, and surrounding tissues in the clinical situations may make the detection of these defects more difficult. Another limitation is that peri-implant dehiscence and fenestration defects were prepared using a diamond bur with a definite border and differed from the naturally occurring defects, which have tapered borders and are more difficult to detect [54].

Conclusion

Within the limitations of the study and the CBCT acquisition parameters used, LD-CBCT can be used without any decrease in diagnostic accuracy for the detection of peri-implant fenestration and dehiscence defects. The use of the MAR algorithm reduces the diagnostic ability of both CBCT scanning protocols for the detection of both peri-implant defects, especially for the dehiscence defect.

Availability of data and materials

All data included in this study are available from the corresponding author upon request.

Abbreviations

CBCT:

Cone beam computed tomography

LD-CBCT:

Low dose cone beam computed tomography

HD-CBCT:

High-definition cone beam computed tomography

MAR:

Metal artifact reduction tool

ROC curve:

Receiver operating characteristic curve

AUC:

Area under curve

DAP:

Dose area product

References

  1. Pye AD, Lockhart DE, Dawson MP, Murray CA, Smith AJ. A review of dental implants and infection. J Hosp Infect. 2009;72:104–10.

    Article  Google Scholar 

  2. de Azevedo-Vaz SL, Peyneau PD, Ramirez-Sotelo LR, de Faria-Vasconcelos K, Campos PSF, Haiter-Neto F. Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscences. Oral Surg Oral Med Oral Pathol Oral Radiol. 2016;121:550–6.

    Article  Google Scholar 

  3. Eskandarloo A, Saati S, Ardakani MP, Jamalpour M, Mezerji NMG, Akheshteh V. Diagnostic accuracy of three cone beam computed tomography systems and periapical radiography for detection of fenestration around dental implants. Contemp Clin Dent. 2018;9:376.

    Google Scholar 

  4. Papapanou PN, Tonetti MS. Diagnosis and epidemiology of periodontal osseous lesions. Periodontol 2000. 2000;22:8–21.

    Article  Google Scholar 

  5. de-Azevedo-Vaz SL, de Faria Vasconcelos K, Neves FS, Melo SLS, Campos PSF, Haiter-Neto F. Detection of periimplant fenestration and dehiscence with the use of two scan modes and the smallest voxel sizes of a cone-beam computed tomography device. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;115:121–7.

    Article  Google Scholar 

  6. Schwarz F, Sahm N, Schwarz K, Becker J. Impact of defect configuration on the clinical outcome following surgical regenerative therapy of peri-implantitis. J Clin Periodontol. 2010;37:449–55.

    Article  Google Scholar 

  7. Dave M, Davies J, Wilson R, Palmer R. A comparison of cone beam computed tomography and conventional periapical radiography at detecting peri-implant bone defects. Clin Oral Implants Res. 2013;24:671–8.

    Article  Google Scholar 

  8. Monsour P, Dudhia R. Implant radiography and radiology. Aust Dent J. 2008;53:S11–25.

    Article  Google Scholar 

  9. Saberi BV, Khosravifard N, Ghandari F, Hadinezhad A. Detection of peri-implant bone defects using cone-beam computed tomography and digital periapical radiography with parallel and oblique projection. Imaging Sci Dent. 2019;49:265–72.

    Article  Google Scholar 

  10. Song D, Shujaat S, de Faria VK, Huang Y, Politis C, Lambrichts I, et al. Diagnostic accuracy of CBCT versus intraoral imaging for assessment of peri-implant bone defects. BMC Med Imaging. 2021;21:23.

    Article  Google Scholar 

  11. De Vos W, Casselman J, Swennen G. Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: a systematic review of the literature. Int J Oral Maxillofac Surg. 2009;38:609–25.

    Article  Google Scholar 

  12. Pelekos G, Acharya A, Tonetti MS, Bornstein MM. Diagnostic performance of cone beam computed tomography in assessing peri-implant bone loss: a systematic review. Clin Oral Implants Res. 2018;29:443–64.

    Article  Google Scholar 

  13. Jaju PP, Jaju SP. Cone-beam computed tomography: time to move from ALARA to ALADA. Imaging Sci Dent. 2015;45:263–5.

    Article  Google Scholar 

  14. Bornstein MM, Scarfe WC, Vaughn VM, Jacobs R. Cone beam computed tomography in implant dentistry: a systematic review focusing on guidelines, indications, and radiation dose risks. Int J Oral Maxillofac Implants. 2014;29(Suppl):55–77.

    Article  Google Scholar 

  15. Yeung AW, Jacobs R, Bornstein MM. Novel low-dose protocols using cone beam computed tomography in dental medicine: a review focusing on indications, limitations, and future possibilities. Clin Oral Investig. 2019;23:2573–81.

    Article  Google Scholar 

  16. Mallya S, Lam E. White and Pharoah’s Oral radiology E-book: principles and interpretation: second South Asia Edition E-Book. Elsevier India; 2019.

    Google Scholar 

  17. Kim JH, Abdala-Júnior R, Munhoz L, Cortes ARG, Watanabe PCA, Costa C, et al. Comparison between different cone-beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects. Imaging Sci Dent. 2020;50:133.

    Article  Google Scholar 

  18. Lee RD. Common image artifacts in cone beam CT. AADMRT Newsletter; 2008. p. 1–7.

    Google Scholar 

  19. Nagarajappa AK, Dwivedi N, Tiwari R. Artifacts: the downturn of CBCT image. J Int Soc Prev Community Dent. 2015;5:440.

    Article  Google Scholar 

  20. Benic GI, Sancho-Puchades M, Jung RE, Deyhle H, Hammerle CH. In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomography. Clin Oral Implants Res. 2013;24:378–83.

    Article  Google Scholar 

  21. de Faria VK, Codari M, Queiroz PM, Nicolielo LFP, Freitas DQ, Sforza C, et al. The performance of metal artifact reduction algorithms in cone beam computed tomography images considering the effects of materials, metal positions, and fields of view. Oral Surg Oral Med Oral Pathol Oral Radiol. 2019;127:71–6.

    Article  Google Scholar 

  22. Cohen JF, Korevaar DA, Altman DG, Bruns DE, Gatsonis CA, Hooft L, et al. STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration. BMJ Open. 2016;6:e012799.

    Article  Google Scholar 

  23. Sheikhi M, Behfarnia P, Mostajabi M, Nasri N. The efficacy of metal artifact reduction (MAR) algorithm in cone-beam computed tomography on the diagnostic accuracy of fenestration and dehiscence around dental implants. J Periodontol. 2020;91:209–14.

    Article  Google Scholar 

  24. Bayrak S, Orhan K, Çakmak ESK, Görürgöz C, Odabaşı O, Yilmaz D, et al. Evaluation of a metal artifact reduction algorithm and an optimization filter in the estimation of peri-implant dehiscence defects by using cone beam computed tomography: an in-vitro study. Oral Surg Oral Med Oral Pathol Oral Radiol. 2020;130:209–16.

    Article  Google Scholar 

  25. Hilgenfeld T, Juerchott A, Deisenhofer UK, Krisam J, Rammelsberg P, Heiland S, et al. Accuracy of cone-beam computed tomography, dental magnetic resonance imaging, and intraoral radiography for detecting peri-implant bone defects at single zirconia implants—an in vitro study. Clin Oral Implants Res. 2018;29:922–30.

    Article  Google Scholar 

  26. Salemi F, Jamalpour MR, Eskandarloo A, Tapak L, Rahimi N. Efficacy of metal artifact reduction algorithm of cone-beam computed tomography for detection of fenestration and dehiscence around dental implants. J Biomed Phys Eng. 2021;11:305.

    Article  Google Scholar 

  27. Domic D, Bertl K, Ahmad S, Schropp L, Hellén-Halme K, Stavropoulos A. Accuracy of cone-beam computed tomography is limited at implant sites with a thin buccal bone: a laboratory study. J Periodontol. 2021;92:592–601.

    Article  Google Scholar 

  28. DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics. 1988;44:837–45.

    Article  Google Scholar 

  29. Renvert S, Persson GR, Pirih FQ, Camargo PM. Peri-implant health, peri-implant mucositis, and peri-implantitis: case definitions and diagnostic considerations. J Clin Periodontol. 2018;45:S278–85.

    Article  Google Scholar 

  30. Kurt MH, Bağış N, Evli C, Atakan C, Orhan K. Comparison of the different voxel sizes in the estimation of peri-implant fenestration defects using cone beam computed tomography: an ex vivo study. Int J Implant Dent. 2020;6:1–11.

    Article  Google Scholar 

  31. Schwindling FS, Hilgenfeld T, Weber D, Kosinski MA, Rammelsberg P, Tasaka A. In vitro diagnostic accuracy of low-dose CBCT for evaluation of peri-implant bone lesions. Clin Oral Implants Res. 2019;30:1200–8.

    Article  Google Scholar 

  32. Pinheiro LR, Gaia BF, de Sales MAO, Umetsubo OS, Junior OS, Cavalcanti MGP. Effect of field of view in the detection of chemically created peri-implant bone defects in bovine ribs using cone beam computed tomography: an in vitro study. Oral Surg Oral Med Oral Pathol Oral Radiol. 2015;120:69–77.

    Article  Google Scholar 

  33. Vasconcelos TV, Nascimento EHL, Bechara BB, Freitas DQ, Noujeim M. Influence of cone beam computed tomography settings on implant artifact production: zirconia and titanium. Int J Oral Maxillofac Implants. 2019;34:1114–20.

    Article  Google Scholar 

  34. Pauwels R, Silkosessak O, Jacobs R, Bogaerts R, Bosmans H, Panmekiate S. A pragmatic approach to determine the optimal kVp in cone beam CT: balancing contrast-to-noise ratio and radiation dose. Dentomaxillofac Radiol. 2014;43:20140059.

    Article  Google Scholar 

  35. Fontenele RC, Farias Gomes A, Nejaim Y, Freitas DQ. Do the tube current and metal artifact reduction influence the diagnosis of vertical root fracture in a tooth positioned in the vicinity of a zirconium implant? A CBCT study. Clin Oral Investig. 2021;25:2229–35.

    Article  Google Scholar 

  36. Sawicki P, Regulski P, Winiarski A, Zawadzki PJ. Influence of exposure parameters and implant position in peri-implant bone assessment in CBCT images: an in vitro study. J Clin Med. 2022;11:3846.

    Article  Google Scholar 

  37. Freitas DQ, Fontenele RC, Nascimento EHL, Vasconcelos TV, Noujeim M. Influence of acquisition parameters on the magnitude of cone beam computed tomography artifacts. Dentomaxillofac Radiol. 2018;47:20180151.

    Article  Google Scholar 

  38. Liljeholm R, Kadesjö N, Benchimol D, Hellén-Halme K, Shi X-Q. Cone-beam computed tomography with ultra-low dose protocols for pre-implant radiographic assessment: an in vitro study. Eur J Oral Implantol. 2017;10:351–9.

    Google Scholar 

  39. Cardarelli LL, Gandhi V, Tadinada A, editors. Evaluation of a new low dose CBCT imaging protocol for measuring circumferential bone levels around dental implants. Medical Imaging 2021: Physics of Medical Imaging; 2021: Int J Opt Photonics.

  40. Schriber M, Yeung AWK, Suter VG, Buser D, Leung YY, Bornstein MM. Cone beam computed tomography artefacts around dental implants with different materials influencing the detection of peri-implant bone defects. Clin Oral Implants Res. 2020;31:595–606.

    Article  Google Scholar 

  41. Aktuna-Belgin C, Serindere G, Belgin H, Serindere M, Orhan K. Efficacy of low dose and ultra-low dose on the visibility of peri-implant fenestration and dehiscences: a computed tomography study. Pol J Radiol. 2022;87:24–9.

    Article  Google Scholar 

  42. Fontenele RC, Nascimento EH, Santaella GM, Freitas DQ. Does the metal artifact reduction algorithm activation mode influence the magnitude of artifacts in CBCT images? Imaging Sci Dent. 2020;50:23–30.

    Article  Google Scholar 

  43. Bechara B, Moore W, McMahan C, Noujeim M. Metal artefact reduction with cone beam CT: an in vitro study. Dentomaxillofac Radiol. 2012;41:248–53.

    Article  Google Scholar 

  44. Demirturk Kocasarac H, Helvacioglu Yigit D, Bechara B, Sinanoglu A, Noujeim M. Contrast-to-noise ratio with different settings in a CBCT machine in presence of different root-end filling materials: an in vitro study. Dentomaxillofac Radiol. 2016;45:20160012.

    Article  Google Scholar 

  45. Shahmirzadi S, Sharaf RA, Saadat S, Moore WS, Geha H, Tamimi D, et al. Assessment of the efficiency of a pre-versus post-acquisition metal artifact reduction algorithm in the presence of 3 different dental implant materials using multiple CBCT settings: an in vitro study. Imaging Sci Dent. 2021;51:1.

    Article  Google Scholar 

  46. Fontenele RC, Machado AH, de Oliveira RL, Freitas DQ. Influence of metal artefact reduction tool on the detection of vertical root fractures involving teeth with intracanal materials in cone beam computed tomography images: a systematic review and meta-analysis. Int Endod J. 2021;54:1769–81.

    Article  Google Scholar 

  47. Kamburoğlu K, Kolsuz E, Murat S, Eren H, Yüksel S, Paksoy C. Assessment of buccal marginal alveolar peri-implant and periodontal defects using a cone beam CT system with and without the application of metal artefact reduction mode. Dentomaxillofac Radiol. 2013;42:20130176.

    Article  Google Scholar 

  48. Bagis N, Kurt MH, Evli C, Camgoz M, Atakan C, Peker Ozturk H, et al. Evaluation of a metal artifact reduction algorithm and an adaptive image noise optimization filter in the estimation of peri-implant fenestration defects using cone beam computed tomography: an in-vitro study. Oral Radiol. 2022;38:325–35.

    Article  Google Scholar 

  49. Meilinger M, Schmidgunst C, Schütz O, Lang EW. Metal artifact reduction in cone beam computed tomography using forward projected reconstruction information. Z Med Phys. 2011;21:174–82.

    Article  Google Scholar 

  50. Korpics M, Surucu M, Mescioglu I, Alite F, Block AM, Choi M, et al. Observer evaluation of a metal artifact reduction algorithm applied to head and neck cone beam computed tomographic images. Int J Radiat Oncol Biol Phys. 2016;96:897–904.

    Article  Google Scholar 

  51. Kratz B, Weyers I, Buzug TM. A fully 3D approach for metal artifact reduction in computed tomography. Med Phys. 2012;39:7042–54.

    Article  Google Scholar 

  52. Mancini AXM, Santos MUC, Gaêta-Araujo H, Tirapelli C, Pauwels R, Oliveira-Santos C. Artefacts at different distances from titanium and zirconia implants in cone-beam computed tomography: effect of tube current and metal artefact reduction. Clin Oral Investig. 2021;25:5087–94.

    Article  Google Scholar 

  53. Gaêta-Araujo H, Leandro Nascimento EH, Cavalcante Fontenele R, Maseti Mancini AX, Queiroz Freitas D, Oliveira-Santos C. Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on conebeam computed tomography with varying tube current. Imaging Sci Dent. 2020;50:1.

    Article  Google Scholar 

  54. Leung CC, Palomo L, Griffith R, Hans MG. Accuracy and reliability of cone-beam computed tomography for measuring alveolar bone height and detecting bony dehiscences and fenestrations. Am J Orthod Dentofac Orthop. 2010;137:S109-119.

    Article  Google Scholar 

Download references

Acknowledgements

We would like to express our gratitude to Dr. Nourhan M. Aly from the Pediatric Dentistry and Dental Public Health Department Faculty of Dentistry, Alexandria University, for her assistance with the statistical analysis of this study.

Funding

Open access funding provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB).

Author information

Authors and Affiliations

Authors

Contributions

AS: conceived and performed the experiments, collected the data, interpreted the results, and wrote the manuscript. YG: revised the manuscript. MRT: contributed to collecting the data, reviewed and edited the manuscript. SAE: designed the experiments, interpreted the results, and contributed to writing the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Shaimaa Abu El Sadat.

Ethics declarations

Ethics approval and consent to participate

Ethical approval was granted by the local Ethics Committee of University in Alexandria university (IRB NO: 00010556-IORG0008839) in view of the in-vitro nature of the study.

Informed consent

For this type of study, formal consent is not required.

Competing interests

The authors declare they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Nomier, A.S., Gaweesh, Y.S.ED., Taalab, M.R. et al. Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study. BMC Oral Health 22, 615 (2022). https://doi.org/10.1186/s12903-022-02663-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12903-022-02663-8

Keywords