Skip to main content

Evaluation of masticatory performance and patient satisfaction for conventional and 3D-printed implant overdentures: a randomized crossover study

Abstract

Background

This crossover clinical study aimed to evaluate and compare masticatory performance and patient satisfaction for patients rehabilitated with conventional heat-cured acrylic resin and 3D-printed mandibular implant overdentures retained with bar attachment.

Materials and methods

Sixteen completely edentulous healthy participants received new conventional dentures. In the mandible, four interforaminal implants were inserted. Following the stage of osseointegration, the bar was constructed in a trapezoidal configuration. Each patient randomly received the following overdentures using a crossover design: (1) conventional heat-cured acrylic resin overdenture and (2) 3D-printed overdenture (developed by scanning of mandibular conventional overdenture). The masticatory performance was assessed by conducting a two-colour mixing ability test at 5, 10, 20, 30, and 50 masticatory cycles. Moreover, the McGill Denture Satisfaction Questionnaire (MDSQ) was employed to assess patient satisfaction. Evaluation was performed after 3 months of using each overdenture. Paired sample t tests were used to compare the masticatory performance and MDSQ scores of patients for both prostheses.

Results

No significant difference in masticatory performance was reported between the two types of overdentures. Regarding patient satisfaction, only the esthetic aspect was significantly better for conventionally processed overdentures than for printed overdentures. Insignificant differences were observed regarding other MDSQ items between the two overdentures.

Conclusion

Within this clinical study, 3D-printed implant overdentures showed promising results in terms of chewing efficiency and patient satisfaction compared to conventionally fabricated implant overdentures.

Trial registration

Retrospectively registered at www.clinicaltrials.gov: NCT06148727.(28/11/2023).

Peer Review reports

Background

Supporting removable prostheses with dental implants has been documented to increase masticatory efficiency and maximum bite force. This is presumably due to the improved retention and stability of the implant-supported prostheses [1, 2]. Therefore, rehabilitation with implant-retained/supported overdentures has greatly enhanced retention and masticatory efficiency, decreased pain during mastication and enabled improved utilization of masticatory muscles, enabling patients to consume a variety of foods [3, 4].

Implants placed in the anterior mandibular ridge have been used to improve function. A range of attachment systems have been implemented to secure the overdenture, including telescopic crowns, magnetic attachments, ball attachments, and bar attachment systems. The stability and retention of the bar attachment system are superior to those of the other systems [5, 6]. They present a rigid anchorage system between the implant and the overdenture without exerting pressure on soft tissues. This technique involves splinting of implants and distributing stresses caused by masticatory forces across multiple implants [7,8,9]. Conversely, mucosal hyperplasia beneath the bar may result from inadequate relief, and conventional casting is a time-consuming procedure. Additionally, it could lead to a greater degree of misfit and porosity in the attachment [10, 11].

Polymethyl methacrylate (PMMA) has been used in most cases for the fabrication of conventional complete dentures [12]. The increased acceptance of this material by patients can be attributed to its biocompatibility, aesthetic qualities, and simplicity of processing and repair [13]. However, PMMA has a number of drawbacks, including polymerization shrinkage, oral microbial colonization, lack of radio-opacity, the potential for allergic reactions due to residual monomers, deterioration of mechanical properties with time, and poor wear resistance. These problems have introduced the need for novel materials and manufacturing techniques [14, 15].

Advancements in digital dentistry have offered new materials and techniques in the fabrication process of this treatment modality. It has invaded the practice of dental work in different fields since its introduction in the 1980s [16]. The initial effort to develop a CAD/CAM system for the production of removable prostheses revealed in 1994 [17]. The advent of digital denture fabrication was initiated in 2012 by Goodacre et al. [18]

There are two primary methods for digitally fabricating removable dental prostheses: additive and subtractive [19]. The subtractive method involves milling the denture base from a prepolymerized resin blank. Subsequently, prefabricated or milled denture teeth are affixed to the milled base. A significant portion of the blank remains underused and is discarded throughout this procedure, which is one of the technique’s drawbacks [20]. The second approach is additive manufacturing (AM), which is alternatively referred to as rapid prototyping (RP) or 3D printing. It entails the implementation of processes to construct three-dimensional models’ layer by layer.

Despite its relatively recent introduction, 3D printing has revolutionized many fields, such as engineering and medicine, including dental work [21]. The utilization of CAD/CAM technology in the fabrication of complete prostheses offers the benefit of simplified laboratory procedures. It has several advantages over conventional techniques, such as dimensional accuracy and standardized fabrication [22]. The aim of this randomized crossover study was to evaluate the impact of the CAD-CAM additive manufacturing technique for implant overdentures on chewing efficiency and patient satisfaction compared to those of conventionally fabricated heat-cured acrylic resin overdentures. The null hypothesis was that there was no significant difference in chewing efficiency or patient satisfaction between the two treatment modalities.

Materials and methods

Study design

A randomized crossover design was used. All patients were provided with two different types of prostheses. This design enabled the standardization of result-influencing variables. Additionally, each patient performed as a self-control. Each patient received two prostheses: conventional and 3D-printed implant overdentures. The same operator constructed all the dentures. Randomization was applied to the order of overdenture insertion to reduce the impact of prosthesis use order on the outcomes. Each overdenture was used for three months, followed by two weeks of rest without wearing a denture; The patient then received the alternative variety of overdenture, which was utilized for an additional three months.

Sample size calculation

The sample size was determined using the findings of a prior clinical trial [23], which revealed a significant difference in chewing efficiency between 3D-printed and conventional prostheses (the α-error was set to 0.05, the β-error was set to 0.20 (80% power), and the effect size was 0.8). The calculated sample size was 12, which was increased to 16 patients to account for any dropouts. The power analysis was performed with the aid of computer software (G*power 3.1.5. Heinrich-Heine-Universität Düsseldorf, Germany).

Patient selection

Nineteen participants aged 45 to 60 years (mean 50 years) were screened for this study from the outpatient clinic of the Prosthodontics Department, Faculty of Dentistry, Mansoura University, from January 2021 to August 2021 (Fig. 1). The main complaint for all patients involved in this study was insufficient retention and stability of the mandibular dentures. All patients were enrolled if they met the following inclusion criteria: adequate bone quantity (class IV-VI Cawood and Howell) [24] of the mandible in the lateral incisor and first premolar regions to receive 4 implants in the interforaminal area as verified by preoperative cone beam computerized tomography and adequate restorative space. The following conditions excluded patients from participation: (1) diabetes mellitus and other diseases that affect bone metabolism; (2) smoking, clenching, and bruxism; and (3) neuromuscular and temporomandibular joint disorders. Three patients were excluded due to limitations in implant placement. Sixteen patients were informed about the treatment plan and the need for repeated calling throughout the total period of the study. The patients were fully informed about the purpose and procedures of this study and provided written informed consent. The study was approved by the local ethical committee of the Faculty of Dentistry, Mansoura University (No. A20011122).

Fig. 1
figure 1

Participant flow diagram. COD: conventional heat-cured acrylic resin overdenture; 3DOD: 3D-printed overdenture

Randomization

Balanced randomization was used to equally assign patients to one of two groups to ensure comparability between groups regarding masticatory efficiency and patient satisfaction. Using random numbers in a Microsoft Excel spreadsheet, participants were randomly assigned to the two groups. The randomization data were generated by a dentist who was blinded to the type of restoration based on the equal distribution of males and females between the two sets. After an adaptation period of three months, masticatory efficiency and patient satisfaction were evaluated for the first eight patients who received conventional overdentures. After a scheduled two-week washout period, the overdenture was replaced with a 3D-printed overdenture, and new recordings were made after an additional three months. The purpose of this random method was to avoid the influence of restoration order on masticatory performance and satisfaction.

Intervention

For each patient, a new conventional complete denture was constructed. Mandibular dentures were duplicated, gutta-percha markers were inserted in mandibular denture duplicates, and patients were subjected to CBCT. Then, the dentures were scanned alone (dual scan protocol). On the software, both scans were superimposed using gutta-percha markers, and 4 interforaminal implants (Biohorizons trx, Biohorizons, USA) were planned according to the available bone width and length. The position of the fixation screws, and the sleeves was determined, and the plan was used for the construction of the stereolithographic surgical guide. Then, the four implants were placed in their positions using flapless protocol and left for osseointegration. After three months, direct transfer copings were placed, and the copings were splinted using ligature wire and composite resin. Then, a direct transfer impression was made using a perforated custom tray and rubber base impression material (Silagum putty and light, DMG, GmbH, Hamburg, Germany). An impression was poured, and bar was constructed with a trapezoidal configuration. After the bar wax pattern (OT Bar Multiuse - Castable Bar, Rhein83, Italy) was finished, it was tried intraorally and then casted in a Co-Cr alloy. After try-in of casted bar, a bite registration was carried out. Arrangement of lower acrylic semi-anatomic teeth was done then waxing up of dentures to be ready for try in the patient mouth. The bilateral balanced occlusal concept using semi-anatomic artificial composite resin teeth (Bredent, Germany) to increase maxillary denture stability [25, 26]. Flasking of waxed denture and packing of PMMA acrylic resin was done to produce final prosthesis. (Fig. 2) Vents were then made; plastic clips were directly picked up with acrylic resin.

Fig. 2
figure 2

Conventional heat-cured maxillary complete denture and mandibular bar-supported overdenture

The master cast/bar assembly of the mandible and the mandibular overdenture were scanned with a 3D scanner (DOF Swing dental scanner, Korea) following a light application of anti-glare spray (Siladent Marmoscan Spray, Basic Ref 250,022 GmbH, Germany) to obtain the standard tessellation language (STL) file format. Using specialized software (Exocad Dental IDB 2.4 plovdiv7290, version 2.4 Engine build 7290, Exocad GmbH) the final complete overdentures were designed over the virtual model. (Fig. 3) Then, the scanned STL image of the conventional overdenture was superimposed onto the newly designed one for comparison of the polished surface, dental alignment, and form of the teeth [27].

Fig. 3
figure 3

3D image of the designed mandibular overdentures (Exocad)

DENTCA Denture Base II (DENTCA, Inc. Torrance, USA), was placed in the cassette of the 3D printer (RASDENT 3D printer, RASPART.eg). The software received the STL file for the denture base model. The denture base was placed on the build platform with its vertical axis. The perimeter of the denture base was created with support and the slice thickness was determined (50 μm), after which the printing process began. The denture teeth were manufactured as a single unit (Fig. 4) using the same technique and tooth resin (DENTCA Denture Tooth, Shade A2, DENTCA, Inc. Torrance, USA).The base was cleansed with isopropyl alcohol (Isopropyl Alcohol Extra Pure, Alpha Chemical) subsequent to the removal of the final supports. The teeth and printed denture base were adhered together using a small quantity of shade-matched light-cured adhesive. Using a traditional technique, wet polishing sand was used to polish the final denture [27]. Then, the plastic clips were picked up to the fitting surface of the 3D-printed denture by the direct functional pickup technique, as performed for conventional overdentures. Four patients dropped out through the follow-up period.

Fig. 4
figure 4

3D-printed denture base and teeth immediately after printing and before bonding

Evaluation

Masticatory performance evaluation

All patients were evaluated for chewing efficiency for both overdentures three months after insertion. Chewing efficiency was evaluated utilizing a two-colour mixing ability test that had been previously documented (colorimetric method) [28] as follows: Chewing gums of two hues (Trident®, Chewing Gum, Mondelez, Egypt) were utilized to create two samples: one flavoured with spearmint (white) and the other with strawberry (red). Two strips of a standardized size (30 × 18 × 3 mm) were manually stuck together. Patients were asked to keep the gum sample intraorally for one minute and then chew it for 5, 10, 20, 30 and 50 strokes, respectively. Five samples were tested with a one-minute interval to reduce fatigue. To make a uniform-thickness wafer, chewed gum was rinsed and sandwiched between two sheets of transparent, rigid plastic with a 1 mm spacer. All samples were then analyzed. From both sides, a Binq 5560c Mirascan® digital scanner (BinQ®, USA) scanned the samples at 600 dots per inch. The scanned image was converted to a fixed size (1175 × 925 pixels) and saved in Adobe Photoshop® format (Photoshop 7.0 ME®—Photo Editor Software—Adobe Systems-Incorporated—USA). Then, the color range tool (fuzziness 20, 25, 30) and histogram function selected the unmixed white areas. From the histogram, both sides’ selected pixels were counted, and their means determined. Subsequently, the mixed fraction (UF) ratio was calculated utilizing the next formula: (Pixels white side a + Pixels white side b) – 2× Pixels of scale/2 × Pixels all. As a reference scale, a scanned piece of unmixed gum was copied in each image (area of 4779 pixelsa) [28].

McGill denture satisfaction questionnaire

Data on patient satisfaction with their mandibular prosthesis were collected using the eight core items of the McGill Denture Satisfaction Questionnaire (MDSQ) [29]. A single inquiry pertains to the general level of satisfaction with current prosthesis, while the remaining seven inquiries target particular factors that might impact overall satisfaction: comfort, ease of cleaning, speech, aesthetics/ appearance, denture stability, chewing ability, and chewing function. The responses were provided by the participants utilizing a visual analogue scale of 100 mm. Patients were motivated to participate in the survey questionnaire following a three-month period of functioning with each type of prosthesis.

Statistical analysis

The data were analysed using SPSS (statistical package for social science) computer software (Version 21 SPSS, Chicago. IL, USA). The distribution of the data was tested using the Shapiro–Wilk test of normality. Normally distributed continuous data are described as the mean ± standard deviation. Paired sample t tests were used to compare the masticatory performance and MDSQ scores of patients on two occasions (when using conventional overdentures and when using printed overdentures). P value less than 0.05 indicated a significant difference at the 95% confidence interval.

Results

A comparison of the masticatory performance evaluation scores between the two groups is shown in Table 1. The hue of variance of the chewing test decreased with increasing number of chewing cycles. In conventional overdenture group, the hue values average was 0.17 ± 0.037, 0.199 ± 0.253, 0.095 ± 0.034, 0.07 ± 0.025 and 0.054 ± 0.022 after five, ten, twenty, thirty and fifty strokes, respectively. In 3D-printed overdenture group, the hue values average was 0.177 ± 0.081, 0.131 ± 0.057, 0.092 ± 0.035, 0.07 ± 0.022, and 0.114 ± 0.248 after five, ten, twenty, thirty and fifty strokes, respectively. There were no statistically significant differences between the two types of overdentures at different chewing strokes (P > 0.05). Table 2 shows the mean MDSQ scores for the two groups. Only the esthetics aspect was significantly better in conventionally processed overdentures than in printed overdentures (P < 0.05). In contrast, no significant differences were observed for the other MDSQ items between the two groups (P > 0.05).

Table 1 Mean values of hue variation at different numbers of chewing strokes between conventional and 3D-printed overdentures
Table 2 MDSQ scores in conventional and 3D-printed overdentures

Discussion

This study utilized a within-patient study design that permits the standardization of patient variables. The optimal time to achieve neuromuscular adaptation after the rehabilitation of edentulous patients with implant-supported overdentures remains controversial in the scientific literature. According to Gartner and colleagues [30], one month is sufficient for achieving coordinated muscle activity. Feine and colleagues [31] assessed the masticatory functions of implant-supported fixed and removable mandibular prostheses after a two-month adaptation period. Van Kampen and coworkers [32] demonstrated that three months of implant overdenture rehabilitation is sufficient to achieve good neuromuscular control. Therefore, a 3-month adaptation period was chosen for both overdentures evaluated in this study. The evaluation of chewing efficiency was conducted using scanning and digital assessment of two-colour chewing gum (mixing ability test) because it has several advantages over the sieving method, including a reduction in the time required to process chewed artificial test food samples, cost effectiveness, and ease of application [33, 34]. The MDSQ is a reliable and valid instrument for evaluating the effectiveness of complete dental prostheses in the mandible of edentulous patients [29].

At different chewing strokes, there was no statistically significant difference between conventional and 3D-printed implant overdentures. This may be because both overdentures are implant-supported; the support is entirely implant-based. In addition, the occlusal surface was replicated for the 3D-printed overdenture by scanning the conventional denture to standardize the size, alignment, and form of the teeth. The improved masticatory performance of both implant overdentures may be due to the increased retention and stability of the mandibular denture provided by the implants, which reportedly enhanced the patient’s ability to grind food while chewing. Furthermore, dental implants enhance osseoperception [35], improve tactile sensation and stereognosis, and enhance chewing ability [36]. Elsyad and coworkers [25] reported that compared with complete dentures, fixed prostheses and milled-bar overdentures significantly improved masticatory efficiency and biting force. Muller and colleagues [37] observed superior chewing efficiency with implant overdentures and implant-supported fixed prostheses in comparison to a complete denture.

There was no statistically significant difference between the two groups on any of the MDSQ items. Only the aesthetic aspect of conventionally processed overdentures was significantly superior to that of printed overdentures. This may be attributed to differences in the manufacturing technique. Prefabricated artificial teeth have greater visual similarity to real teeth with different visible areas of translucency and optical properties, whereas 3D-printed artificial teeth are similar to resin teeth in terms of physical properties but have a single-colour tone and may become discoloured more readily [38, 39]. There was also a difference in the colour of the pink part of the maxillary denture compared to that of the 3D-printed mandibular overdenture, which might be attributed to patient satisfaction with the aesthetic aspect of the 3D-printed overdenture.

Regarding masticatory performance, both conventional and 3D-printed implant overdentures are reliable and recommended treatment options. In contrast to conventional overdentures, 3D-printed overdentures are anticipated to reduce patients’ physical burden by decreasing the number of clinic visits required for denture fabrication [40, 41]. However, additional research is required to confirm the long-term clinical efficacy of 3D-printed implant overdentures.

This study was limited by its small sample size, short-term evaluation, and washout periods. The implementation of a formal lengthy washout period would have necessitated a long period during which the overdenture was not used; however, it was not ethically permissible to do so in this study. Nonetheless, as demonstrated by the results, the influence of the carryover effect can be considered minimal, as there was no significant difference between the two treatment options regarding masticatory performance.

Conclusions

Within the limitations of this clinical study, 3D-printed implant overdentures showed promising results regarding chewing efficiency and patient satisfaction compared to conventionally fabricated implant overdentures. 3D-printed implant overdentures could be a viable option for patients with less aesthetic concerns.

Data availability

The datasets analysed during the current study are available from the corresponding author on reasonable request.

Abbreviations

3d:

Three dimensional

MDSQ:

McGill Denture Satisfaction Questionnaire

CAD/CAM:

Computer-aided design and computer-aided manufacturing

PMMA:

Polymethyl methacrylate

AM:

Additive manufacturing

RP:

Rapid prototyping

CBCT:

Cone beam computed tomography

Co-Cr alloy:

Cobalt-chromium alloy

STL file:

Standard tessellation language file format

UV light:

Ultraviolet light

UF:

Ratio of mixed fraction

References

  1. Bilhan H, Erdogan O, Ergin S, Celik M, Ates G, Geckili O. Complication rates and patient satisfaction with removable dentures. J Adv Prosthodont. 2012;4:109–15.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Nogueira TE, Schimmel M, Leles CR. Changes in masticatory performance of edentulous patients treated with single implant mandibular overdentures and conventional complete dentures. J Oral Rehabil. 2019;46:268–73.

    Article  CAS  PubMed  Google Scholar 

  3. Boven GC, Raghoebar GM, Vissink A, Meijer HJ. Improving masticatory performance, bite force, nutritional state and patient’s satisfaction with implant overdentures: a systematic review of the literature. J Oral Rehabil. 2015;42:220–33.

    Article  CAS  PubMed  Google Scholar 

  4. Marco M, Giuliano B, Luca O. Oral rehabilitation with implant-supported overdenture and a new protocol for bar passivation. Glob J Oral Sci. 2016;2:10–9.

    Article  Google Scholar 

  5. Takeshita S, Kanazawa M, Minakuchi S. Stress analysis of mandibular two-implant overdenture with different attachment systems. Dent Mater J. 2011;30:928–34.

    Article  PubMed  Google Scholar 

  6. van Kampen F, Cune M, van der Bilt A, Bosman F. Retention and post insertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function. Clin Oral Implants Res. 2003;14:720–6.

    Article  PubMed  Google Scholar 

  7. Galindo DF. The implant-supported milled-bar mandibular overdenture. J Prosthodont. 2001;10:46–51.

    Article  CAS  PubMed  Google Scholar 

  8. Bedrossian E, Sullivan RM, Fortin Y, Malo P, Indresano T. Fixed prosthetic implant restoration of the edentulous maxilla: a systematic pretreatment evaluation method. J Oral Maxillofac Surg. 2008;66:112–22.

    Article  PubMed  Google Scholar 

  9. Krennmair G, Krainhöfner M, Piehslinger E. Implant-supported maxillary overdentures retained with milled bars: maxillary anterior versus maxillary posterior concept–a retrospective study. Int J Oral Maxillofac Implants. 2008;23:343–52.

    PubMed  Google Scholar 

  10. Karabuda C, Tosun T, Ermis E, Ozdemir, TJJop. Comparison of 2 retentive systems for implant-supported overdentures: soft tissue management and evaluation of patient satisfaction. 2002;73(9):1067–70.

  11. Pozzi A, Tallarico M, Moy PKJTJ. Four-implant overdenture fully supported by a CAD-CAM titanium bar: a single-cohort prospective 1-year preliminary study. 2016;116(4):516–23.

  12. Murray MD, Darvell BW. The evolution of the complete denture base. Theories of complete denture retention—a review. Part 3. Aust Dent J. 1993;38:389–93.

    Article  CAS  PubMed  Google Scholar 

  13. Vojdani M, Bagheri R, Khaledi AAR. Effects of aluminum oxide addition on the flexural strength, surface hardness, and roughness of heat-polymerized acrylic resin. J Dent Sci. 2012;7:238–44.

    Article  Google Scholar 

  14. Gautam R, Singh RD, Sharma VP, Siddhartha R, Chand P, Kumar R. Biocompatibility of polymethylmethacrylate resins used in dentistry. J Biomed Mater Res B Appl Biomater. 2012;100:1444–50.

    Article  PubMed  Google Scholar 

  15. Akin H, Tugut F, Polat ZA. In vitro comparison of the cytotoxicity and water sorption of two different denture base systems. J Prosthodont. 2015;24:152–5.

    Article  PubMed  Google Scholar 

  16. Miyazaki T, Hotta Y, Kunii J, Kuriyama S, Tamaki Y. A review of dental CAD/ CAM: current status and future perspectives from 20 years of experience. Dent Mater J. 2009;28:44–56.

    Article  PubMed  Google Scholar 

  17. Maeda Y, Minoura M, Tsutsumi S, Okada M, Nokubi T. A CAD/CAM system for removable denture. Part I: fabrication of complete dentures. Int J Prosthodont. 1994;7:17–21.

    CAS  PubMed  Google Scholar 

  18. Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. J Prosthet Dent. 2012;107:34–46.

    Article  PubMed  Google Scholar 

  19. Schweiger J, Stumbaum J, Edelhof D, Guth JF. Systematics and concepts for the digital production of complete dentures: risks and opportunities. Int J Comput Dent. 2018;21:41–56.

    PubMed  Google Scholar 

  20. Goodacre BJ, Goodacre CJ. Additive Manufacturing for Complete Denture Fabrication: a narrative review. J Prosthodont. 2022;31:47–51.

    Article  PubMed  Google Scholar 

  21. Anadioti E, Kane B, Soulas E. Current and emerging applications of 3D printing in restorative dentistry. Curr Oral Health Rep. 2018;5:133–9.

    Article  Google Scholar 

  22. Alghazzawi TF. Advancements in CAD/CAM technology: options for practical implementation. J Prosthodont Res. 2016;60:72–84.

    Article  PubMed  Google Scholar 

  23. Ragheb N, Ibrahim W. Biting force and chewing efficiency of conventional and CAD/CAM complete dentures. A cross-over study. Egypt Dent J. 2021;67:3323–35.

    Article  Google Scholar 

  24. Cawood JI, Howell RA. A classification of the edentulous jaws. Int J Oral Maxillofac Surg. 1988;17:232–6.

    Article  CAS  PubMed  Google Scholar 

  25. Elsyad MA, Tella EAES, Mohamed SS, Mahrous AI. Within-patient evaluation of chewing efficiency and maximum bite force of conventional dentures, fixed prostheses, and milled bar overdentures used for all‐on‐4 implant rehabilitation of atrophied mandibular ridges: a short‐term randomized trial. Clin Implant Dent Relat Res. 2022;24:522–31.

    Article  PubMed  Google Scholar 

  26. Khamis MM, Zaki HS, Rudy TE. A comparison of the effect of different occlusal forms in mandibular implant overdentures. J Prosthet Dent. 1998;79:422–9.

    Article  CAS  PubMed  Google Scholar 

  27. Emera RMK, Shady M, Alnajih MA. Comparison of retention and denture base adaptation between conventional and 3D-printed complete dentures. J Dent Res Dent Clin Dent Prospects. 2022;16(3):179–85.

    Article  PubMed  PubMed Central  Google Scholar 

  28. Schimmel M, Christou P, Herrmann F, Muller F. A two color chewing gum test for masticatory efficiency: development of different assessment methods. J Oral Rehabil. 2007;34:671–8.

    Article  CAS  PubMed  Google Scholar 

  29. De Souza RF, Ribeiro AB, Oates TW, Feine JS. The McGill denture satisfaction questionnaire revisited: exploratory factor analysis of a binational sample. Gerodontology. 2020;37:233–43.

    Article  PubMed  Google Scholar 

  30. Gartner JL, Mushimoto K, Weber HP, Nishimura I. Effect of osseointegrated implants on the coordination of masticatory muscles: a pilot study. J Prosthet Dent. 2000;84:185–93.

    Article  CAS  PubMed  Google Scholar 

  31. Feine JS, Maskawi K, de Grandmont P, Donohue WB, Tanguay R, Lund JP. Within-subject comparisons of implant-supported mandibular prostheses: evaluation of masticatory function. J Dent Res. 1994;73:1646–56.

    Article  CAS  PubMed  Google Scholar 

  32. van Kampen FM, van der Bilt A, Cune MS, Bosman F. The influence of various attachment types in mandibular implant-retained overdentures on maximum bite force and EMG. J Dent Res. 2002;81:170–3.

    Article  PubMed  Google Scholar 

  33. Jasser E, Salami Z, El Hage F, Makzoume J, Boulos PJ. Masticatory efficiency in implant-supported fixed complete dentures compared with conventional dentures: a randomized clinical trial by color-mixing analysis test. Int J Oral Maxillofac Implants. 2020;35:599–606.

    Article  PubMed  Google Scholar 

  34. van der Bilt A, Mojet J, Tekamp FA, Abbink JH. Comparing masticatory performance and mixing ability. J Oral Rehabil. 2010;37(2):79–84.

    Article  PubMed  Google Scholar 

  35. Trulsson M, Francis ST, Bowtell R, McGlone F. Brain activations in response to vibrotactile tooth stimulation: a psychophysical and fMRI study. J Neurophysiol. 2010;104:2257–65.

    Article  PubMed  Google Scholar 

  36. Yan C, Ye L, Zhen J, Ke L, Gang L. Neuroplasticity of edentulous patients with implant-supported full dentures. Eur J Oral Sci. 2008;116:387–93.

    Article  PubMed  Google Scholar 

  37. Muller F, Hernandez M, Grutter L, Aracil-Kessler L, Weingart D, Schimmel M. Masseter muscle thickness, chewing efficiency and bite force in edentulous patients with fixed and removable implant supported prostheses: a cross-sectional multicenter study. Clin Oral Implants Res. 2012;23:144–50.

    Article  PubMed  Google Scholar 

  38. Cha HS, Park JM, Kim TH, Lee JH. Wear resistance of 3D-printed denture tooth resin opposing zirconia and metal antagonists. J Prosthet Dent. 2020;124:387–94.

    Article  CAS  PubMed  Google Scholar 

  39. Ohara K, Isshiki Y, Hoshi N, Ohno A, Kawanishi N, Nagashima S, Inoue M, Kubo D, Yamaya K, Inoue E, Kimoto K. Patient satisfaction with conventional dentures vs. digital dentures fabricated using 3D-printing: a randomized crossover trial. J Prosthodont Res. 2022;66:623–9.

    Article  PubMed  Google Scholar 

  40. Bidra AS, Farrell K, Burnham D, Dhingra A, Taylor TD, Kuo CL. Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: clinical and patient-centered outcomes. J Prosthet Dent. 2016;115:578–86.

    Article  PubMed  Google Scholar 

  41. Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent. 2013;109:361–6.

    Article  PubMed  Google Scholar 

Download references

Funding

This research is self-funded. Open access publication is provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB).

Author information

Authors and Affiliations

Authors

Contributions

Nabil M.S., as the first author, collected the clinical data and supervised all the procedures. Said M.M. designed the study and performed the statistical analysis. Mahanna F. F., as a corresponding author, prepared the manuscript and interpreted the data. All authors critically discussed the results, revised the manuscript, and approved the final version.

Corresponding author

Correspondence to Fatma Fathe Mahanna.

Ethics declarations

Ethics approval and consent to participate

The patients were fully informed about the purpose and procedures of this study and provided written informed consent. The study was approved by the local ethical committee of the Faculty of Dentistry, Mansoura University (No. A20011122) and retrospectively registered at ClinicalTrials.gov (ClinicalTrials.gov Identifier: NCT06148727 ) (28/11/2023).

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Nabil, M.S., Mahanna, F.F. & Said, M.M. Evaluation of masticatory performance and patient satisfaction for conventional and 3D-printed implant overdentures: a randomized crossover study. BMC Oral Health 24, 672 (2024). https://doi.org/10.1186/s12903-024-04389-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12903-024-04389-1

Keywords