Evaluation of setting kinetics, mechanical strength, ion release, and cytotoxicity of high-strength glass ionomer cement contained elastomeric micelles

Abstract

Background

Low mechanical properties are the main limitation of glass ionomer cements (GICs). The incorporation of elastomeric micelles is expected to enhance the strength of GICs without detrimentally affecting their physical properties and biocompatibility. This study compared the chemical and mechanical properties, as well as the cytotoxicity, of elastomeric micelles-containing glass ionomer cement (DeltaFil, DT) with commonly used materials, including EQUIA Forte Fil (EF), Fuji IX GP Extra (F9), and Ketac Molar (KT).

Method

Powder particles of GICs were examined with SEM-EDX. Setting kinetics were assessed using ATR-FTIR. Biaxial flexural strength/modulus and Vickers surface microhardness were measured after immersion in water for 24 h and 4 weeks. The release of F, Al, Sr, and P in water over 8 weeks was analyzed using a fluoride-specific electrode and ICP-OES. The toxicity of the material extract on mouse fibroblasts was also evaluated.

Results

High fluoride levels in the powder were detected with EF and F9. DT demonstrated an initial delay followed by a faster acid reaction compared to other cements, suggesting an improved snap set. DT also exhibited superior flexural strength than other materials at both 24 h and 4 weeks but lower surface microhardness (p < 0.05). EF and F9 showed higher release of F, Al, and P than DT and KT. There was no statistically significant difference in fibroblast viability among the tested materials (p > 0.05).

Conclusions

Elastomeric micelles-containing glass ionomer cement (DT) exhibited satisfactory mechanical properties and cytocompatibility compared with other materials. DT could, therefore, potentially be considered an alternative high-strength GIC for load-bearing restorations.

Peer Review reports

Background

The phasing down of dental amalgam, as part of the Minamata Convention, led to the need for alternative direct restorative materials [1]. Resin composites and glass ionomer cements (GICs) were suggested as good candidates [2]. Several studies reported satisfactory success with high-viscosity GICs for single or two-surface posterior restorations [3,4,5]. GICs were also reported to be a cost-effective restorative material [6,7,8,9]. The attractive properties of GICs include fluoride release, self-adhesion, and preventive effects on secondary caries by releasing multiple ions such as fluoride, strontium, and phosphate [10].

The setting mechanism of GICs is an acid-base reaction [11]. This reaction involves the neutralizing polyacrylic acids in the liquid phase by ions released from fluoroaluminosilicate glass in the powder phase, forming a network of polyacrylate salts [12]. The low flexural strength is a significant limitation of the GICs, as material fracture is one of the primary causes of failure in GIC restorations [13]. The reported flexural strength of conventional GICs at 24 h post-setting was approximately 18–34 MPa [14]. These values are substantially lower than those of resin composite, which generally exhibit flexural strength higher than 100 MPa [15, 16]. Another major concern is the low wear resistance of GICs [17]. A clinical study indicated that the clinical performance of GICs substantially decreased after 6 years due to deterioration of occlusal contour and wear [13]. A negative correlation between wear and surface microhardness of GICs has also been reported [18].

Various strategies have been proposed to enhance the mechanical strength and abrasive resistance of glass ionomer cements. One approach was metal reinforcement by incorporating metal power or silver-tin alloys into the material [19]. However, the metal-reinforced GICs failed to demonstrate an enhancement in material strength and exhibited no clinical benefits, mainly due to their poor esthetics [19, 20]. Another strategy involved incorporating reactive glass fibers. It was observed that adding these fibers (600 μm in length) at a concentration of 20 vol% approximately doubled the strength of a GIC [19]. Despite promising results, such methods have not been widely adopted in commercial materials. A recent alternative method for enhancing the mechanical strength involves incorporating polyethylene glycol (PEG) and polyurethane (PU) nanoparticles into GIC (Deltafil, DMG, Hamburg, Germany) [21]. These particles will form PEG-PU micelles with elastic structures. The ductile particles in brittle GICs were expected to help disperse energy at crack tips and form bridging zones to delay crack propagation [22].

Previous studies reported that Deltafil exhibited higher fracture toughness than other conventional GICs [21, 23]. The material was also found to demonstrate superior longevity compared to Ketac Universal and Fuji IX GP Extra upon the chewing simulation of occlusal restoration (Class I cavity) [21]. Deltafil exhibited lower abrasion loss or wear than other GICs [21], suggesting its potential suitability for load-bearing restorations. Despite these beneficial effects, the reports on the chemical, mechanical, and cytotoxic properties of GICs containing PEG-PU micelles are limited.

This study, therefore, aims to compare the setting reaction, biaxial flexural strength, surface microhardness, ion release, and cytotoxicity of GIC-containing elastomeric micelles (Deltafil) with other commonly used high-viscosity conventional GICs. The null hypothesis was that Deltafil would not exhibit significant differences in these properties when compared to other commercial GICs.

Methods

Characterization of GICs

Four commercial high-viscosity glass ionomer cements were used in the current study (Table 1). The characteristics of glass fillers and elemental analysis were performed using a scanning electron microscope (SEM, JSM 7800 F, JEOL Ltd., Tokyo, Japan) equipped with an energy-dispersive X-ray spectrometer (EDX, X-Max 20, Oxford Instruments, Abingdon, UK). The powder of GICs was coated with Au (Q150R ES, Quorum Technologies, East Sussex, UK) using a current of 23 mA for 45 s. The test used a beam voltage of 10 kV and the working distance set at 10 mm. The single-point EDX analysis was performed in 3 areas of the filler particle.

Table 1 Composition of conventional glass ionomer cements used in the current study

Setting kinetics

The setting kinetics of GICs were determined using attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR, Nicolet iS5, Thermo Fisher Scientific, Waltham, MA, USA) (n = 3). Immediately after 10 s of mixing using an amalgamator (CapMix, 3 M ESPE, St. Paul, MN, USA), the materials were injected into the diamond of the ATR. Then, the FTIR spectra (400–4000 cm–1) were recorded from the bottom surface every 30 s for 10 min using a resolution of 4 cm–1. The test was performed at 25 °C. Key peak assignments for each chemical group are provided in Table 2. Peak loss and gain during the acid/base reaction were obtained by subtracting the initial spectra from those at later times to provide different spectra.

Table 2 Peak assignments for reactive acidic and product salt groups in GICs [24, 25]

The reaction extent (RE) of acid neutralization reactions (degree of acid-base neutralization) was determined based on the reduction of the peak representing the acid group according to the method used in a previous study [25].

$$RE=100* \frac{{A}_{t}-{A}_{0}}{{A}_{f}-{A}_{0}}$$
(1)

where A0 and At were the absorbance at 1714 cm–1 initially and at time, t, respectively. The final absorbance (Af) at infinite time (i.e., when 1/t = 0) was determined from the intercept on the y-axis of plots of late-time absorbance versus 1/t.

Biaxial flexural strength (BFS) and modulus (BFM)

For biaxial flexural strength and modulus determination (n = 10), the GICs were mixed and loaded into a metal circlip (10 mm internal diameter and 1 mm in thickness). The discs were covered with an acetate sheet and glass slide. They were left at room temperature for 1 h and subsequently removed from the circlip and placed in 5 mL of deionized water. The specimens were kept in an incubator at 37ºC for 24 h or 4 weeks, then removed and placed in a ball-on-ring testing jig. They were loaded using a 500 N load cell and a crosshead speed of 1 mm/min. The failure load was recorded, and then biaxial flexural strength (BFS) and modulus (BFM) were calculated using the following equations [26].

$$\text{B}\text{F}\text{S} = \frac{\text{F}}{{\text{d}}^{2}}\left\{\left(1 + \text{v}\right)\left[0.485\text{l}\text{n}\left(\frac{\text{r}}{\text{d}}\right) + 0.52\right] + 0.48\right\}$$
(2)
$$\text{B}\text{F}\text{M} = \left(\frac{{\Delta }\text{H}}{{\Delta }{\text{W}}_{\text{c}}}\right)\times \left(\frac{{{\beta }}_{\text{c}}{d}^{2}}{{\text{q}}^{3}}\right)$$
(3)

where F is the failure load (N), d is the thickness of the disc specimens (m), r is the radius of the circular support of the ball-on-ring testing jig (m), and v is Poisson’s ratio (0.3) [26]. Additionally, \(\frac{{\Delta }\text{H}}{{\Delta }{\text{W}}_{\text{c}}}\) represents the rate of change of the load about the central deflection or gradient of force versus the displacement curve (N/m) [27]. \({{\upbeta }}_{\text{c}}\) and q are the center deflection function (0.5024) and the ratio of the support radius to the specimen radius, respectively. The fracture surface of the representative tested specimen from each material was determined using SEM-EDX using a similar protocol to the first section. The EDX single-point analysis was performed from 3 areas on the fracture surface.

Surface microhardness

For surface microhardness determination, disc specimens (10 mm in diameter and 1 mm in thickness) were prepared similarly to the previous section (n = 5). The specimens were immersed in 5 mL of deionized water. The Vickers surface microhardness of the specimens after immersion for 24 h was then recorded using a Vickers microhardness tester (FM-800, Future-Tech, Kanagawa, Japan). The measurement was performed using a load of 300 g with an indentation time of 10 s [28]. The result was averaged from 4 areas and expressed as Vickers hardness number (VHN). The specimens were then placed in the same solution, and the Vickers surface microhardness of the same specimens was then repeated at 4 weeks.

Ion release

Fluoride release in deionized water from disc specimens (n = 5) was assessed using a fluoride-specific electrode (Orion Versastar Pro, Thermo Fisher Scientific, Waltham, MA, USA). Fluoride concentrations of 1, 10, 100, and 1000 ppm were used for calibration. Disc specimens (10 mm in diameter and 1 mm in thickness) were prepared similarly to the previous section. They were immersed in a tube containing 5 mL of deionized water. The specimens were kept in an incubator with a controlled temperature of 37ºC for up to 8 weeks. At various time points (1, 2, 3, 4, 5 days and 1, 2, 3, 4, 5, 6, 7, and 8 weeks), the specimens were removed and placed in a fresh solution. The storage solution from each time point was mixed with TISABIII using a 1:10 volume ratio. The concentration of fluoride was then measured.

For Al, P, and Sr release, another set of disc specimens (n = 5) was prepared and immersed in tubes containing 5 mL of deionized water. The tubes were kept at 37ºC for 8 weeks; then, the specimens were removed, and the storage solution was collected. The calibration standard was performed using an Environmental Standard (CPAchem, Bogomilovo, Bulgaria). The concentration of each element was determined using inductively coupled plasma optical emission spectrometry (ICP-OES, Optima 8300, PerkinElmer, Waltham, MA, USA). The detection range of Al, P, and Sr were 0.1–50 mg/L, 0.5–50 mg/L, and 0.1–20 mg/L, respectively.

Cytotoxicity

Cytotoxicity testing of the extracts from disc specimens was conducted following a protocol reported in previous studies [29, 30]. Disc specimens (10 mm in diameter and 1 mm in thickness) were prepared and sterilized by 30-min UV irradiation on each of their top and bottom surfaces (n = 5). The specimens were then immersed in 200 µL of Dulbecco’s modified Eagle medium (DMEM, Gibco, Thermo Fisher Scientific, Grand Island, NY, USA) with 10% FBS (Gibco), 1% penicillin/streptomycin (Gibco) and 1% L-glutamine (Gibco) added. The specimens were left for 5 h at room temperature. Then, 50 µL of the medium was pipette mixed with an equal volume of fresh medium for a two-fold dilution and subsequently transferred to 96-well plates. These plates were seeded with mouse fibroblast L292 cells at a density of 8 × 103 cells/well, with plain culture medium serving as the blank control.

The cells were cultured at 37 °C in a humidified atmosphere containing 5% CO2 for 72 h. Then, the MTT solution (0.5 mg/mL) (Invitrogen, Thermo Fisher Scientific, Grand Island, NY, USA) was added to each well for 30 min. The reaction was terminated by 100 µL of dimethylsulfoxide (Sigma‒Aldrich, St. Louis, MO, USA). The final product’s color was quantified by measuring the absorbance at 570 and 650 nm (OD, optical density) using a microplate reader spectrophotometer (Varioskan LUX Multimode, Thermo Fisher Scientific, Grand Island, NY, USA). The relative cell viability (%) was calculated according to the following Eqs. [31, 32]. The assay was conducted in triplicate.

$$Relative\,cell\,viability= \frac{OD\,of\,the\,test\,group}{OD\,of\,the\,control}\times 100$$
(4)

Statistical analysis

Results for quantitative analysis, including absorbance change, BFS/BFM, surface microhardness, ion release, and cytotoxicity. These data were presented as mean and 95%CI. Data were analyzed using Prism for macOS version 10.1.1 (GraphPad Software, San Diego, CA, USA). The normality of data was checked using the Shapiro-Wilk test. Then, the results between groups were compared using one-way ANOVA followed by Tukey post-hoc multiple comparisons. Power analysis was performed using G*power version 3.1.9.6 (Heinrich Heine University Düsseldorf, Düsseldorf, Germany) [33]. The effect size was calculated using the results from the previous studies [34, 35]. These estimations suggested that the sample size used in each test would provide power greater than 0.95 at an alpha level of 0.05 for one-way ANOVA.

Results

Characterization of GICs

SEM images (Fig. 1) showed that the powder phase of all materials consisted of a mix of small and large particle diameters. Additionally, EDX results indicated higher fluorine content (atomic%) in EF and F9 compared to DT and KT. The average fluorine content (mean ± SD) measured from 3 points of each material was 23 ± 2% for DT, 30 ± 4% for EF, 27 ± 7% for F9, and 11 ± 9% for KT.

Fig. 1
figure 1

The SEM images of the powder phase and the elemental composition of each material

Setting kinetics

Example FTIR spectra versus time after mixing are provided in Fig. 2A. During the set, GICs showed a decrease in peak absorbance at 1705 cm–1 due to the loss of the carboxylic acid group (COOH) and an increase in multiple polyacrylate salt peaks at lower wavenumbers. The pattern of changes obtained from all materials was similar, which was presented by a representative sample from DT. Difference spectra (obtained by subtracting the initial spectrum from those at later times) for all materials given in Fig. 2B-D. Whilst with DT (Fig. 2B), there was a delay before significant absorbance change, with all other cements, no delay was observed. The relative intensities of different salt peaks showed only minor variations with time for a given cement but could vary between cements. For example, difference spectra for DT and KT at 10 min demonstrated greater absorbance change at 1554 and 1410 cm–1 than F9 and EF (Fig. 2F).

The average initial absorbance at 1705 cm–1 was similar for DT, F9, and EF (p > 0.05), suggesting comparable initial levels of polyacid (Fig. 3A). However, the initial absorbance of KT was significantly higher than EF (p = 0.013). Maximum extrapolated absorbance change following reaction, however, was greater for DT and KT than for F9 and EF (Fig. 3A). The extrapolated absorbance change of EF was significantly lower than both DT (p = 0.006) and KT (p = 0.002). Using the 1705 cm–1 acid peak, a clear delay in the reaction can be observed for DT followed by a rapid reaction between 3 and 5 min (Fig. 3B). For all other cements, there was a steady reaction up to 5 min. The reaction rate slowed for all cements after 5 min. Reaction levels at 10 min were ~ 70% of extrapolated final values in all cases.

Fig. 2
figure 2

(A) Representative FTIR spectra of DT, (B-E) changes of spectra of all materials, and (F) the changes of spectra for all cement at 10 min. Difference spectra were calculated by subtracting the initial spectrum from that at later times. The reduction of the peak at 1705 cm–1 due to the neutralization of the polyacid was used to calculate the reaction extent

Fig. 3
figure 3

(A) Average of initial absorbance change at 1705 cm–1 and the maximum extrapolated absorbance change at 1705 cm–1. Data are mean and 95% CI (n = 3). The same lower-case and upper-case letters indicated p < 0.05 for the initial and extrapolated maximum change, respectively. (B) The changes in average reaction extent over time obtained from a representative sample of each group

Biaxial flexural strength (BFS) and modulus (BFM)

At 24 h (Fig. 4A), the highest BFS was observed for DT (62 ± 6 MPa). Other materials were statistically similar (p > 0.05), presenting significantly lower BFS in comparison to DT (p < 0.01). This trend continued at 4 weeks, with all groups showing a significant increase in BFS after storage (p < 0.05).

For BFM at 24 h (Fig. 4B), DT also showed the highest value (2.4 ± 0.4 GPa)(p < 0.05). No significant differences were detected between EF, F9, and KT (p > 0.05). After 4 weeks, the BFM of all materials increased significantly (p < 0.05). The BFM of DT (2.7 ± 0.4 GPa) remained significantly higher than that of EF and KT (p < 0.05) but was not significantly different from F9 (2.2 ± 0.4 GPa)(p = 0832).

Fracture surfaces of the representative specimen from each material showed the remaining glass fillers in the matrix (Fig. 5). EDX analysis indicated that multiple elements such as F, Si, and Al were detected on the fracture surfaces in all materials.

Fig. 4
figure 4

(A) Biaxial flexural strength and (B) biaxial flexural modulus after 24 h and 4 weeks of immersion in deionized water. Data are mean and 95% CI (n = 10). The same lower-case and upper-case letters indicate p < 0.05 for results at 24 h and 4 weeks, respectively

Fig. 5
figure 5

The SEM images and EDX analysis of fracture surfaces from representative samples of each material after BFS testing at 4 weeks

Surface microhardness

At 24 h (Fig. 6), KT exhibited the highest surface microhardness (71.1±1.0 VHN), which was significantly higher than DT (57.8±3.2 VHN), EF (63.6±6.1 VHN), and F9 (62.5±2.4 VHN) (p < 0.05). At 4 weeks, surface microhardness values of all materials increased significantly (p < 0.05). KT maintained the highest value (80.6 ± 2.8 VHN), which was significantly greater than both DT (70.1 ± 1.2 VHN) and F9 (74.5 ± 3.3 VHN) (p < 0.01).

Fig. 6
figure 6

Vickers surface microhardness after 24 h and 4 weeks of immersion in deionized water. Data are mean and 95% CI (n = 5). The same lower-case and upper-case letters indicate p < 0.05 for results at 24 h and 4 weeks, respectively

Ion release

An initial burst release of fluoride was observed at 24 h (Fig. 7A). EF and F9 showed a continual increase in fluoride release over the 8-week measurement period. In contrast, for DT and KT, the increase was slower, beginning to level off at approximately 1 week. The highest cumulative fluoride release at 8 weeks (Fig. 7B) was from EF (58.4 ± 4.2 ppm), which was significantly higher than F9 (49.8 ± 1.7 ppm), DT (12.2 ± 1.8 ppm), and KT (12.4 ± 0.3 ppm) (p < 0.05). The fluoride release from DT was comparable to that of KT (p = 0.990).

EF and F9 also exhibited higher releases of Al and P than DT and KT (Table 3). Additionally, DT showed a significantly higher release of Al, P, and Sr compared to KT (p < 0.05).

Fig. 7
figure 7

(A) Fluoride release versus square root of time in hours upon immersion in deionized water for 8 weeks. (B) The cumulative release of fluoride at 8 weeks for each material. Data are mean and 95% CI (n = 5). Line indicated p > 0.05

Table 3 The mean (95% CI) of the concentration of elements after immersion in deionized water for 8 weeks. The same letters in each row indicate a significant difference between materials (p < 0.05)

Cytotoxicity

The highest cell viability of mouse fibroblast after exposure to extract from each material was observed from DT (88 ± 4%), followed by KT (87 ± 4%), F9 (84 ± 3%), and EF (80 ± 6%) as shown in Fig. 8. However, no significant difference was detected among the materials (p > 0.05).

Fig. 8
figure 8

Percentage of cell viability of mouse fibroblast after exposure to extract from specimens of each material. Data are mean and 95% CI (n = 10). The line indicates p > 0.05

Discussion

This study compared the physical and mechanical properties of novel conventional elastomeric micelles-containing GICs (DT) with other commonly used materials. The results indicated that DT had significantly higher biaxial flexural strength than the other materials but exhibited lower fluoride release than EF and F9. Therefore, the null hypothesis was rejected.

The setting reaction of glass ionomer cement (GICs) is based on an acid-base reaction between polyacrylic acid and the fluoroaluminosilicate glass in the cement powder [36]. Therefore, a reduction in the FTIR peak representing the acid group in the spectroscopic analysis was used as an indicator of the acid reacting with the glass to form polyacrylate salts [25]. It was expected that the high level of acid-base reaction could potentially promote strong crosslinking of glass-matrix interaction, ultimately enhancing the mechanical properties of GICs [37, 38]. A slight delay in the inhibition of the reaction (approximately 2 min after the start of data collection) was observed for DT, which could be attributed to the effect of tartaric acids [11]. These acids may act as intermediates, forming tartrate salts before the final reaction between their anions and the carboxylic groups of the polyacrylic acid [36]. This inhibition time could provide a working time for GIC to be placed and adapted within the prepared cavity before a rapid snap setting [39]. However, it should be mentioned that the manufacturers did not reveal the actual composition of each product. Therefore, a direct comparison may not be possible.

This study assessed the setting reaction of GICs for up to 10 min. Hence, the setting kinetics observed in this study may only be suitable for assessing the kinetics during the hardening times (1.5–6 min) required by BS EN ISO 9917-1 2007 Dentistry-Water-based cements [40]. From a clinical perspective, faster reaction kinetics may indicate a quick setting for GIC, potentially reducing the susceptibility to fracture due to early mastication on the restoration [41]. However, the setting reactions of GICs can continue for several months [42]. This could be, therefore, considered a limitation of the current study, requiring future tests to determine the setting kinetics over longer time points.

The high flexural strength value would help ensure the suitability of GICs for placing in load-bearing cavities such as Class II restorations in posterior teeth. While there is currently no specific standard for the minimum flexural strength of GICs, the ISO 4049:2019 (Dentistry-Polymer-based restorative materials) requires a minimum flexural strength of 80 MPa for polymer-based restorative materials intended for permanent restorations in occlusal areas [43]. None of the GICs in this study met this recommended threshold. This may imply that these materials should be primarily used in conservative load-bearing cavities or Class I atraumatic restorative treatment (ART) restoration [44,45,46]. DT exhibited the highest BFS at 24 h (~ 62 MPa), which was slightly higher than previously reported ranges of 45–58 MPa from the 3-point bending test [23]. This discrepancy could be attributed to different testing protocols. Biaxial flexural strength testing was reported to show higher strength and greater reliability compared with the 3-point bending test [47]. This could be due to the uniform stress distribution, easy control in preparing small specimens, increased survival at a given load due to smaller volume, and narrow defect distribution [47, 48].

The highest BFS of DT could be due to its higher powder-to-liquid ratio (4.9:1) compared with other materials (3.0:1 to 3.6:1) [35]. Another explanation could be that the elastomeric micelles may help seal or delay the crack propagation. However, the effects of delayed crack propagation should be confirmed in future work using fracture toughness or fatigue testing [49]. The lack of assessment of mechanical behavior upon cyclic loading or fatigue testing is a limitation of the current study. The fatigue test may be more relevant to confirm the crack-inhibiting actions for DT because the restorations were subjected to a sub-critical repeated loading [50].

An increase in flexural strength and surface microhardness was detected in all GICs upon immersion in water. This may be due to the maturation process of the setting reaction of GICs [42]. The reduction in modulus of elasticity could be due to the dissolution of glass, which may reduce the rigidity of the material [35]. Another possibility could be the increase in unbound water, which could act as a plasticizer, reducing the rigidity of the polymer matrix in GICs [51].

EF and F9 showed higher fluoride release compared to other materials. This was in accordance with a previous study [52] and a consensus that ranked EF and F9 as the first and third materials of choice among conventional GICs for long-term restorative materials [53]. The level of fluoride release was governed by several key factors, such as the composition of the glass, the porosity and solubility of materials, the molecular weight of a polyacid, and the powder-to-liquid ratio [35, 54, 55]. EDX analysis of the powder phase showed that EF and F9 contained higher levels of fluoride compared with other materials., which may partly explain the higher level of fluoride release observed with EF and F9. This result was obtained from a single-point EDX analysis from the glass particles, which should be interpreted with caution.

The releasing profile of fluoride from GICs in this study was in accordance with a diffusion-controlled pattern reported in the previous study [56]. This pattern usually consists of an initial burst release at ~ 24 h, which was attributed to the rapid washout of fluoride from the cement occurring during the initial setting phase [57]. Then, acid-base reactions continue at a slower rate, resulting in a sustained release of fluoride at low levels that could last from several months up to 3 years [58, 59]. A limitation of this study was that the duration of fluoride and other elemental releases was monitored for only approximately 2 months. It was expected that the GICs would continue to exhibit ion-release actions over time. Future studies should investigate both ion-releasing and rechargeability [60] of the materials over extended periods (e.g., 12–36 months) to assess their long-term remineralizing potential.

It should be mentioned that the minimum requirement for fluoride release to promote clinical benefits for caries management from the ISO standard for GICs has not been established. It was, however, suggested that fluoride at a concentration of 0.03–0.7 ppm could inhibit mineral loss and enhance remineralization in dentin [10]. This may be associated with the reduction of S. mutans and inhibits the bacteria from metabolizing carbohydrates [55, 61]. Furthermore, all tested materials provided elemental release other than fluoride, such as Al, Sr, and P. A high level of elemental release was generally observed in EF. According to the manufacturer, the powder phase of EF contains a mixture of large and small particles of highly reactive fluoroaluminosilicate glass, referred to as a “glass hybrid material” [62]. This highly reactive glass may increase interaction with acids, resulting in a greater level of elemental release. The release of multiple elements was expected to enhance the bioactive properties of GICs, such as promoting mineralization or providing buffering effects [11, 63]. For example, the replacement of Ca with Sr in glass ionomer cement showed an increase in the radiopacity of the material and enhanced tooth remineralization [64, 65]. Sr was also believed to exhibit synergistic effects with fluoride in controlling dental biofilm [66]. It should be noted that Sr was not detected in the powder phase by the EDX, which could be due to the low concentration of the element in the glass network compared with other elements.

The conventional glass ionomer cement added with elastomeric micelles demonstrated cell viability comparable to that of commonly used commercial materials. The percentage of viability of all materials was greater than 70% relative to the blank control. This may suggest that all materials complied with the requirement of ISO 10993-5:2009, Biological evaluation of medical devices Part 5: Tests for in vitro cytotoxicity [31]. According to the standard, a reduction in cell viability greater than 30% is considered cytotoxic [31]. The results from the current study also correlated with the previous study, which indicated the good biocompatibility of conventional GICs to both L929 mouse fibroblasts and human dental pulp cells [67]. A satisfactory cytocompatibility was usually observed with conventional GICs compared with resin-modified GICs due mainly to the lack of toxic components such as 2-hydroxyethyl methacrylate [11, 68, 69].

The Minamata Convention advocates for the phasing down of dental amalgam to mitigate the environmental risk of releasing mercury waste into the environment [70]. The available alternative direct restorative materials, such as GICs, have improved over time but still exhibit limited strength and questionable long-term performance [71]. The current study demonstrated that GIC added with elastomeric micelles exhibited satisfactory mechanical properties and ion-releasing actions, suggesting its potential as an alternative GIC material. However, it is important to mention that this is an in vitro study. Therefore, clinical studies are necessary to assess the long-term effectiveness of this material compared with other GICs or resin composite in clinical settings.

Conclusions

The novel glass ionomer cement containing elastomeric micelles (DT) exhibited similar levels of acid-base neutralization, surface microhardness, and cytotoxicity as compared to other commercial materials. However, DT has demonstrated superior strength. While DT exhibited lower levels of fluoride release than the commonly used GICs, it still falls within the range observed with a commercial comparison. These findings suggest that DT could be considered a viable option for load-bearing restorations where conventional GIC is deemed suitable.

Data availability

The datasets used and/or analyzed during the current study available from the corresponding author on reasonable request.

Abbreviations

ART:

Atraumatic restorative treatment

ATR-FTIR:

Attenuated total reflectance-Fourier transform infrared spectroscopy

BFS:

Biaxial flexural strength

BFM:

Biaxial flexural modulus

DT:

Deltafil

EDX:

Energy Dispersive X-Ray Analysis

EF:

EQUIA Forte HT Fil

F9:

Fuji IX GP Extra

GICs:

Glass ionomer cements

ICP-OES:

Inductively coupled plasma-optical emission spectrometry

KT:

Ketac molar

MTT:

3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide

PEG:

Polyethylene glycol

PU:

Polyurethane

SEM:

Scanning electron microscopes

VHN:

Vickers hardness number

References

  1. Fisher J, Varenne B, Narvaez D, Vickers C. The Minamata Convention and the phase down of dental amalgam. Bull World Health Organ. 2018;96(6):436–8.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Dhar V, Pilcher L, Fontana M, Gonzalez-Cabezas C, Keels MA, Mascarenhas AK, Nascimento M, Platt JA, Sabino GJ, Slayton R, et al. Evidence-based clinical practice guideline on restorative treatments for caries lesions: a report from the American Dental Association. J Am Dent Assoc. 2023;154(7):551–e566551.

    Article  PubMed  Google Scholar 

  3. Gurgan S, Kutuk ZB, Yalcin Cakir F, Ergin E. A randomized controlled 10 years follow up of a glass ionomer restorative material in class I and class II cavities. J Dent. 2020;94:103175.

    Article  PubMed  Google Scholar 

  4. Gurgan S, Kutuk Z, Ozturk C, Soleimani R, Cakir F. Clinical performance of a glass hybrid restorative in extended size class II cavities. Oper Dent. 2020;45(3):243–54.

    Article  CAS  PubMed  Google Scholar 

  5. Ruengrungsom C, Burrow MF, Parashos P, Palamara JEA. Evaluation of F, ca, and P release and microhardness of eleven ion-leaching restorative materials and the recharge efficacy using a new Ca/P containing fluoride varnish. J Dent. 2020;102:103474.

    Article  CAS  PubMed  Google Scholar 

  6. Schwendicke F, Basso M, Markovic D, Turkun LS, Miletic I. Long-term cost-effectiveness of glass hybrid versus composite in permanent molars. J Dent. 2021;112:103751.

    Article  PubMed  Google Scholar 

  7. Olegário IC, Ladewig NM, Hesse D, Bonifácio CC, Braga MM, Imparato JCP, Mendes FM, Raggio DP. Is it worth using low-cost glass ionomer cements for occlusal ART restorations in primary molars? 2-year survival and cost analysis of a randomized clinical trial. J Dent. 2020;101:103446.

    Article  PubMed  Google Scholar 

  8. Schwendicke F, Rossi JG, Krois J, Basso M, Peric T, Turkun LS, Miletic I. Cost-effectiveness of glass hybrid versus composite in a multi-country randomized trial. J Dent. 2021;107:103614.

    Article  CAS  PubMed  Google Scholar 

  9. Schwendicke F, Muller A, Seifert T, Jeggle-Engbert LM, Paris S, Gostemeyer G. Glass hybrid versus composite for non-carious cervical lesions: survival, restoration quality and costs in randomized controlled trial after 3 years. J Dent. 2021;110:103689.

    Article  CAS  PubMed  Google Scholar 

  10. Ge KX, Quock R, Chu CH, Yu OY. The preventive effect of glass ionomer cement restorations on secondary caries formation: a systematic review and meta-analysis. Dent Mater. 2023;39(12):e1–17.

    Article  CAS  PubMed  Google Scholar 

  11. Sidhu SK, Nicholson JW. A review of Glass-Ionomer cements for Clinical Dentistry. J Funct Biomater. 2016;7(3):E16.

    Article  Google Scholar 

  12. Mickenautsch S. High-viscosity glass-ionomer cements for direct posterior tooth restorations in permanent teeth: the evidence in brief. J Dent. 2016;55:121–3.

    Article  CAS  PubMed  Google Scholar 

  13. Heck K, Frasheri I, Diegritz C, Manhart J, Hickel R, Fotiadou C. Six-year results of a randomized controlled clinical trial of two glass ionomer cements in class II cavities. J Dent. 2020;97:103333.

    Article  CAS  PubMed  Google Scholar 

  14. Moberg M, Brewster J, Nicholson J, Roberts H. Physical property investigation of contemporary glass ionomer and resin-modified glass ionomer restorative materials. Clin Oral Investig. 2019;23(3):1295–308.

    Article  PubMed  Google Scholar 

  15. Nagaoka H, Bishop S, Roberts H. Flexural Performance of Direct Resin Composite Restorative materials Past Expiration date. Eur J Dent. 2020;14(2):217–23.

    Article  PubMed  PubMed Central  Google Scholar 

  16. Alshabib A, Silikas N, Watts DC. Hardness and fracture toughness of resin-composite materials with and without fibers. Dent Mater. 2019;35(8):1194–203.

    Article  CAS  PubMed  Google Scholar 

  17. Kielbassa AM, Oehme EP, Shakavets N, Wolgin M. In vitro wear of (resin-coated) high-viscosity glass ionomer cements and glass hybrid restorative systems. J Dent. 2021;105:103554.

    Article  CAS  PubMed  Google Scholar 

  18. Peutzfeldt A, Garcia-Godoy F, Asmussen E. Surface hardness and wear of glass ionomers and compomers. Am J Dent. 1997;10(1):15–7.

    CAS  PubMed  Google Scholar 

  19. Nicholson JW, Sidhu SK, Czarnecka B. Enhancing the Mechanical properties of Glass-Ionomer Dental cements: a review. Mater (Basel). 2020;13(11):2510.

    Article  CAS  Google Scholar 

  20. Baig MS, Fleming GJ. Conventional glass-ionomer materials: a review of the developments in glass powder, polyacid liquid and the strategies of reinforcement. J Dent. 2015;43(8):897–912.

    Article  CAS  PubMed  Google Scholar 

  21. Messer-Hannemann P, Samadi M, Bottcher H, Duy S, Duy D, Albrecht N, Schwendicke F, Effenberger S. Evaluation of a method to determine wear resistance of class I tooth restorations during cyclic loading. Mater (Basel). 2022;15(15):5440.

    Article  CAS  Google Scholar 

  22. Sigl LS, Mataga PA, Dalgleish BJ, McMeeking RM, Evans AG. On the toughness of brittle materials reinforced with a ductile phase. Acta Metall. 1988;36(4):945–53.

    Article  CAS  Google Scholar 

  23. Messer-Hannemann P, Bottcher H, Henning S, Schwendicke F, Effenberger S. Concept of a Novel Glass Ionomer Restorative Material with Improved Mechanical properties. J Funct Biomater. 2023;14(11):534.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  24. Young A. FTIR investigation of polymerisation and polyacid neutralisation kinetics in resin-modified glass-ionomer dental cements. Biomaterials. 2002;23(15):3289–95.

    Article  CAS  PubMed  Google Scholar 

  25. Young AM, Rafeeka SA, Howlett JA. FTIR investigation of monomer polymerisation and polyacid neutralisation kinetics and mechanisms in various aesthetic dental restorative materials. Biomaterials 2004, 25(5):823–33.

  26. Walters NJ, Xia W, Salih V, Ashley PF, Young AM. Poly(propylene glycol) and urethane dimethacrylates improve conversion of dental composites and reveal complexity of cytocompatibility testing. Dent Mater. 2016;32(2):264–77.

    Article  CAS  PubMed  Google Scholar 

  27. Chaichana W, Insee K, Chanachai S, Benjakul S, Aupaphong V, Naruphontjirakul P, Panpisut P. Physical/mechanical and antibacterial properties of orthodontic adhesives containing Sr-bioactive glass nanoparticles, calcium phosphate, and andrographolide. Sci Rep. 2022;12(1):6635.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  28. Thepveera W, Potiprapanpong W, Toneluck A, Channasanon S, Khamsuk C, Monmaturapoj N, Tanodekaew S, Panpisut P. Rheological Properties, Surface Microhardness, and Dentin Shear Bond Strength of Resin-Modified Glass Ionomer cements containing methacrylate-functionalized polyacids and spherical Pre-reacted Glass Fillers. J Funct Biomater. 2021;12(3):42.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  29. Potiprapanpong W, Thepveera W, Khamsuk C, Channasanon S, Tanodekaew S, Patntirapong S, Monmaturapoj N, Panpisut P. Monomer Conversion, Dimensional Stability, Biaxial Flexural Strength, Ion Release, and cytotoxicity of Resin-Modified Glass Ionomer cements containing methacrylate-functionalized polyacids and spherical Pre-reacted Glass Fillers. Polym (Basel). 2021;13(16):2742.

    Article  CAS  Google Scholar 

  30. Thanyasiri S, Naruphontjirakul P, Padunglappisit C, Mirchandani B, Young AM, Panpisut P. Assessment of physical/mechanical properties and cytotoxicity of dual-cured resin cements containing Sr-bioactive glass nanoparticles and calcium phosphate. Dent Mater J 2023, 42(6):806–17.

  31. British S. 10993–5: 2009 Biological evaluation of medical devices. Part 5: tests for in vitro cytotoxicity. London, UK: BSI Standards Limited; 2009.

    Google Scholar 

  32. Pagano S, Lombardo G, Balloni S, Bodo M, Cianetti S, Barbati A, Montaseri A, Marinucci L. Cytotoxicity of universal dental adhesive systems: Assessment in vitro assays on human gingival fibroblasts. Toxicol Vitro. 2019;60:252–60.

    Article  CAS  Google Scholar 

  33. Faul F, Erdfelder E, Lang AG, Buchner A. G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods. 2007;39(2):175–91.

    Article  PubMed  Google Scholar 

  34. Panpisut P, Monmaturapoj N, Srion A, Toneluck A, Phantumvanit P. Physical Properties of Glass Ionomer Cement Containing Pre-reacted Spherical Glass Fillers. Braz Dent J 2020, 31(4):445–52.

  35. Panpisut P, Monmaturapoj N, Srion A, Angkananuwat C, Krajangta N, Panthumvanit P. The effect of powder to liquid ratio on physical properties and fluoride release of glass ionomer cements containing pre-reacted spherical glass fillers. Dent Mater J 2020, 39(4):563–70.

  36. Young AM, Sherpa A, Pearson G, Schottlander B, Waters DN. Use of Raman spectroscopy in the characterisation of the acid-base reaction in glass-ionomer cements. Biomaterials 2000, 21(19):1971–9.

  37. Monmaturapoj N, Soodsawang W, Tanodekaew S. Enhancement effect of pre-reacted glass on strength of glass-ionomer cement. Dent Mater J 2012, 31(1):125–30.

  38. Zimehl R, Hannig M. Non metallic restorative materials based on glass ionomer cements — recent trends and developments. Colloids Surf a: Physicochem Eng Asp. 2000;163(1):55–62.

    Article  CAS  Google Scholar 

  39. Valliant EM, Dickey BT, Price R, Boyd D, Filiaggi MJ. Fourier transform infrared spectroscopy as a tool to study the setting reaction in glass-ionomer cements. Mater Lett. 2016;185:256–9.

    Article  CAS  Google Scholar 

  40. British Standard. BS EN ISO 9917-1 2007 Dentistry-Water-based cements. Part 1: Powder/liquid acid-based cement. Brussel: British Standards; 2007.

    Google Scholar 

  41. Tsuzuki FM, Pascotto RC, Malacarne LC, Bento AC, Medina Neto A, de Castro-Hoshino LV, Souza M, Nicholson JW, Baesso ML. Studies of the early stages of the dynamic setting process of chemically activated restorative glass-ionomer cements. Biomater Investig Dent. 2021;8(1):39–47.

    CAS  PubMed  PubMed Central  Google Scholar 

  42. Nicholson JW. Maturation processes in glass-ionomer dental cements. Acta Biomater Odontol Scand. 2018;4(1):63–71.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  43. British Standard. BS EN ISO 4049:2019. In: Dentistry-Polymer- based restorative materials. Switzerland: BSI Standards; 2019.

    Google Scholar 

  44. Cribari L, Madeira L, Roeder RBR, Macedo RM, Wambier LM, Porto TS, Gonzaga CC, Kaizer MR. High-viscosity glass-ionomer cement or composite resin for restorations in posterior permanent teeth? A systematic review and meta-analyses. J Dent. 2023;137:104629.

    Article  CAS  PubMed  Google Scholar 

  45. Ruengrungsom C, Palamara JEA, Burrow MF. Comparison of ART and conventional techniques on clinical performance of glass-ionomer cement restorations in load bearing areas of permanent and primary dentitions: a systematic review. J Dent. 2018;78:1–21.

    Article  CAS  PubMed  Google Scholar 

  46. Miletic I, Baraba A, Basso M, Pulcini MG, Markovic D, Peric T, Ozkaya CA, Turkun LS. Clinical performance of a Glass-Hybrid System compared with a Resin Composite in the posterior region: results of a 2-year Multicenter Study. J Adhes Dent. 2020;22(3):235–47.

    PubMed  Google Scholar 

  47. Palin WM, Fleming GJ, Burke FJ, Marquis PM, Randall RC. The reliability in flexural strength testing of a novel dental composite. J Dent. 2003;31(8):549–57.

    Article  CAS  PubMed  Google Scholar 

  48. Ilie N, Hilton TJ, Heintze SD, Hickel R, Watts DC, Silikas N, Stansbury JW, Cadenaro M, Ferracane JL. Academy of Dental materials guidance-Resin composites: part I-Mechanical properties. Dent Mater. 2017;33(8):880–94.

    Article  CAS  PubMed  Google Scholar 

  49. Alvanforoush N, Wong R, Burrow M, Palamara J. Fracture toughness of glass ionomers measured with two different methods. J Mech Behav Biomed Mater. 2019;90:208–16.

    Article  CAS  PubMed  Google Scholar 

  50. Chen S, Ohman C, Jefferies SR, Gray H, Xia W, Engqvist H. Compressive fatigue limit of four types of dental restorative materials. J Mech Behav Biomed Mater. 2016;61:283–9.

    Article  CAS  PubMed  Google Scholar 

  51. Singer L, Bierbaum G, Kehl K, Bourauel C. Evaluation of the Flexural Strength, Water Sorption, and solubility of a Glass Ionomer Dental Cement Modified using Phytomedicine. Mater (Basel). 2020;13(23):5352.

    Article  CAS  Google Scholar 

  52. Moshaverinia M, Navas A, Jahedmanesh N, Shah KC, Moshaverinia A, Ansari S. Comparative evaluation of the physical properties of a reinforced glass ionomer dental restorative material. J Prosthet Dent. 2019;122(2):154–9.

    Article  CAS  PubMed  Google Scholar 

  53. de Lima Navarro MF, Pascotto RC, Borges AFS, Soares CJ, Raggio DP, Rios D, Bresciani E, Molina GF, Ngo HC, Miletic I, et al. Consensus on glass-ionomer cement thresholds for restorative indications. J Dent. 2021;107:103609.

    Article  PubMed  Google Scholar 

  54. Kumari PD, Khijmatgar S, Chowdhury A, Lynch E, Chowdhury CR. Factors influencing fluoride release in atraumatic restorative treatment (ART) materials: a review. J Oral Biol Craniofac Res. 2019;9(4):315–20.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  55. Nicholson JW, Sidhu SK, Czarnecka B. Fluoride exchange by glass-ionomer dental cements and its clinical effects: a review. Biomater Investig Dent. 2023;10(1):2244982.

    PubMed  PubMed Central  Google Scholar 

  56. Nicholson JW, Coleman NJ, Sidhu SK. Kinetics of ion release from a conventional glass-ionomer cement. J Mater Sci Mater Med. 2021;32(4):30.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  57. Nicholson J, Czarnecka B. Conventional glass-ionomer cements. In: Materials for the Direct Restoration of Teeth. edn. Edited by Nicholson J, Czarnecka B: Woodhead Publishing; 2016: 107–136.

  58. Forsten L. Fluoride release and uptake by glass-ionomers and related materials and its clinical effect. Biomaterials. 1998;19(6):503–8.

    Article  CAS  PubMed  Google Scholar 

  59. Wiegand A, Buchalla W, Attin T. Review on fluoride-releasing restorative materials–fluoride release and uptake characteristics, antibacterial activity and influence on caries formation. Dent Mater. 2007;23(3):343–62.

    Article  CAS  PubMed  Google Scholar 

  60. Madi F, Sidhu SK, Nicholson JW. The effect of temperature and ionic solutes on the fluoride release and recharge of glass-ionomer cements. Dent Mater. 2020;36(1):e9–14.

    Article  CAS  PubMed  Google Scholar 

  61. Chau NP, Pandit S, Jung JE, Cai JN, Yi HK, Jeon JG. Long-term anti-cariogenic biofilm activity of glass ionomers related to fluoride release. J Dent. 2016;47:34–40.

    Article  CAS  PubMed  Google Scholar 

  62. Moshaverinia M, de Almeida Queiroz Ferreira L, Smidt G, Shah KC, Ansari S, Moshaverinia A. Evaluation of mechanical, optical, and fluoride-releasing properties of a translucent bulk fill glass hybrid restorative dental material. J Esthet Restor Dent. 2024;36(3):503–10.

    Article  PubMed  Google Scholar 

  63. Nicholson JW, Sidhu SK, Czarnecka B. Can glass polyalkenoate (glass-ionomer) dental cements be considered bioactive? A review. Heliyon 2024.

  64. Shahid S, Hassan U, Billington RW, Hill RG, Anderson P. Glass ionomer cements: effect of strontium substitution on esthetics, radiopacity and fluoride release. Dent Mater. 2014;30(3):308–13.

    Article  CAS  PubMed  Google Scholar 

  65. Ghilotti J, Fernandez I, Sanz JL, Melo M, Llena C. Remineralization potential of three restorative Glass Ionomer cements: an in Vitro Study. J Clin Med. 2023;12(6):2434.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  66. Lippert F, Hara AT. Strontium and caries: a long and complicated relationship. Caries Res. 2013;47(1):34–49.

    Article  CAS  PubMed  Google Scholar 

  67. Ersahan S, Oktay EA, Sabuncuoglu FA, Karaoglanoglu S, Aydin N, Suloglu AK. Evaluation of the cytotoxicity of contemporary glass-ionomer cements on mouse fibroblasts and human dental pulp cells. Eur Arch Paediatr Dent. 2020;21(3):321–8.

    Article  CAS  PubMed  Google Scholar 

  68. Potiprapanpong W, Naruphontjirakul P, Khamsuk C, Channasanon S, Toneluck A, Tanodekaew S, Monmaturapoj N, Young AM, Panpisut P. Assessment of Mechanical/Chemical Properties and cytotoxicity of Resin-Modified Glass Ionomer cements containing Sr/F-Bioactive Glass nanoparticles and Methacrylate Functionalized Polyacids. Int J Mol Sci. 2023;24(12):10231.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  69. Ribeiro APD, Sacono NT, Soares DG, Bordini EAF, de Souza Costa CA, Hebling J. Human pulp response to conventional and resin-modified glass ionomer cements applied in very deep cavities. Clin Oral Investig. 2019;24(5):1739–48.

    Article  PubMed  Google Scholar 

  70. World Dental Federation F. D. I. Alternative direct restorative materials to dental amalgam. Int Dent J. 2024;74(1):161–2.

  71. Panetta A, Lopes P, Novaes TF, Rio R, Fernandes GVO, Mello-Moura ACV. Evaluating Glass Ionomer Cement Longevity in the primary and permanent Teeth—An Umbrella Review. J Funct Biomater. 2024;15(2):48.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

This study was supported by the Faculty of Dentistry and Thammasat University Research Unit in Dental and Bone Substitutes Dental Biomaterials, Thammasat University, Thailand. We would also like to express our gratitude for the support from Bualuang ASEAN Chair Professor Fund.

Funding

This study was funded by Graduate Research Fund, Faculty of Dentistry, Thammasat University, and Thailand Science Research and Innovation Fundamental Fund.

Author information

Authors and Affiliations

Authors

Contributions

Nitchakarn Leenutaphong: methodology, Formal analysis, Investigation, Data Curation, Writing - Original Draft, Visualization. Prathip Phantumvanit: Conceptualization, Methodology, Resources, Project administration, Funding Acquisition. Anne M. Young: Conceptualization, Methodology, validation, Formal analysis, Data Curation, Writing - Review & Editing, Visualization, Supervision. Piyaphong Panpisut: Conceptualization, Methodology, Validation, Formal analysis, Resources, Writing - Original Draft, Writing - Review & Editing, Visualization, Supervision, Project administration, Funding Acquisition.

Corresponding author

Correspondence to Piyaphong Panpisut.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Leenutaphong, N., Phantumvanit, P., Young, A.M. et al. Evaluation of setting kinetics, mechanical strength, ion release, and cytotoxicity of high-strength glass ionomer cement contained elastomeric micelles. BMC Oral Health 24, 713 (2024). https://doi.org/10.1186/s12903-024-04468-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12903-024-04468-3

Keywords